351 resultados para Extraoral Traction Appliances


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this retrospective study was to analyze the cases of traumatic dental injuries involving root fracture and/or periodontal ligament injury (except avulsion) treated at the Discipline of Integrated Clinic, School of Dentistry of Araçatuba, São Paulo State University (UNESP), Brazil, from January 1992 to December 2002. Clinical and radiographic records from 161 patients with 287 traumatized teeth that had sustained root fracture and/or injuries to the periodontal ligament were examined. The results of this survey revealed that subluxation (25.09%) was the most common type of periodontal ligament injury, followed by extrusive luxation (19.86%). There was a predominance of young male patients and most of them did not present systemic alterations. Among the etiologic factors, the most frequent causes were falls and bicycle accidents. Injuries on extraoral soft tissues were mostly laceration and abrasion, while gingival and lip mucosa lacerations prevailed on intraoral soft tissues injuries. Radiographically, the most common finding was an increase of the periodontal ligament space. The most commonly performed treatment was root canal therapy. Within the limits of this study, it can be concluded that traumatic dental injuries occur more frequently in young male individuals, due to falls and bicycle accidents. Subluxation was the most common type of periodontal ligament injury. Root canal therapy was the type of treatment most commonly planned and performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The behaviour of the non conserved and 98% glycerin conserved specimens for periods of 30, 60 and 90 days of bovine diaphragma's tendinous center, fibrous pericardium and parietal peritoneum submitted to mechanical tests of traction, was observed in ten bovines between 30 months and 36 months of age, crossbreeds, males and females, collecting fragments of these aforesaid membranes in each animal. The diaphragma's tendinous center and parietal peritoneum did not suffered significant modification (p>0.05) in the values of tension when compared to the resistance tests of traction of non conserved and 98% glycerin conserved membranes. However, all the evaluated tissues showed significant increase (p£0.05) of the elongation values when conserved in 98% glycerin for until 90 days. It was also observed that fibrous pericardium is the one which supports greaters tensions. So, it to was concluded, that glycerin is efficient to the conservation of biological membranes besides modifying its mechanical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The snoring is produced by the vibration of the soft palatum and/or other oropharyngeal tissues, during the air passage, in the breathing function. OSAHS is defined as the closing of 30%, at least, of the nasal/ buccal airway for 10 seconds or more, in spite of existing inspiratory effort, accompanied by oxyhemoglobin de- saturation of 4% or more. Objectives: To evaluate the available scientific evidence about the use of mandibular advancement intraoral appliances in the treatment of the snoring and/or OSAHS. Methodology: Electronic search strategy using predefined key-words and criteria was realized including studies published until October of 2008. It was also used the qualitative evaluation of the articles methodology. Results: Although a significant number of articles has studied this subject, only 7 articles showed methodological quality to be included in this systematic review. Conclusions: The intraoral appliances are widely prescribed for the treatment of snoring and OSAHS as primary therapy and as an alternative to patients who are unable to tolerate the positive airway pressure therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept of power drive system suitable for application in traction systems of electrical vehicles pulled by electrical motors, which can be powered by urban DC or AC distribution networks. The proposed front-end structure is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode as AC-DC converter, or as DC-DC converter, in order to provide the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards resulting in significant improvements for the trolleybuses systems efficiency and for the urban distribution network costs. Considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, two digital control strategies were evaluated. The digital controller has been implemented using a low cost FPGA (XC3S200) and developed totally using a hardware description language VHDL and fixed point arithmetic. Experimental results from a 15 kW low power scale prototype operating in DC and AC conditions are presented, in order to verify the feasibility and performance of the proposed system. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposal presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results of a 15kW prototype are also presented in this paper. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esthetic orthodontic appliances continue to appeal to more patients, which results in objections to extraction spaces that remain for several months during orthodontic therapy. This has led orthodontists to design temporary pontics that fill extraction sites and that can be reduced as the spaces close. This report describes a simple, efficient, and expeditious technique for making such pontics. © 2010 Quintessence Publishing Co, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Oral lichen planus (OLP) is a chronic autoimmune disease characterized by multiple clinical presentations and a relatively high prevalence in the population. This retrospective patient record study investigated the profile of OLP in a group of Brazilian patients seen between 1989 and 2009. Findings. The clinical records were analyzed and data such as gender, age, race, clinical presentation of OLP, site affected, presence of symptoms and extraoral manifestations of the disease, smoking habit, and consumption of alcoholic beverages were obtained. Among the 1822 records of patients with oral mucosal lesions, OLP was identified in 6.03%. Of these, 76.36% were females, with a mean age of 54 years, and 85% were whites. The reticular form was the most frequent (81.81%). Extraoral lesions were observed in 32.72% of the patients and painful symptoms were reported by 50.90%. The cheek mucosa was the site most affected (92.72%) and multiple oral lesions were observed in 77.27% of the patients. Among patients with OLP, 18.18% reported a smoking habit and 29.09% the consumption of alcoholic beverages. Conclusions. This retrospective study showed a relatively high prevalence of OLP in the population studied, with a predominance of the disease among middle-aged white women and bilateral involvement of the cheek mucosa. Reticular lesions were the most frequent, followed by the erosive form which is mainly associated with painful symptoms. No relationship with tobacco or alcohol consumption was observed. © 2010 Almeida et al; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objeti vo: Avaliar os efeitos da expansão lenta na maxila e na mandíbula com o aparelho ortodônti co removível superior com torno de expansão simétrico e mediano, nas regiões oclusal, gengival e alveolar de pacientes jovens com atresia maxilar. Método: A amostra compreendeu 18 indivíduos leucodermas (11 meninas e 7 meninos; idade média: 8 anos e 10 meses no início do tratamento) que apresentavam atresia da maxila, acompanhadas ou não de mordida cruzada posterior uni ou bilateral na fase de denti ção mista. Todos os pacientes foram tratados com aparelho ortodônti co removível superior com torno de expansão simétrico e mediano, sendo o tempo médio de tratamento de 15,4 meses (± 7,6). Para avaliar a infl uência do tratamento nas mensurações dos pontos demarcados nas regiões oclusal, gengival e alveolar, foram uti lizados os modelos de gesso dos arcos superior e inferior (36 pares) obti dos em dois tempos: T1: início do tratamento e T2: ao fi nal do tratamento. Para cada paciente em ambos os tempos, foram mensuradas as distâncias transversas na região oclusal entre caninos decíduos, 1o molares decíduos ou 1o pré-molares permanentes e entre 1o molares permanentes, superiores e inferiores. Para verifi car se a movimentação ocorreu por inclinação ou por movimento de corpo, foram uti lizadas também medidas nas regiões gengival e alveolar. Os dados foram avaliados estati sti camente pelo teste “t student para amostras pareadas (5%). Resultados: Observou-se que em T2, todas as distâncias mensuradas para as regiões oclusal, gengival e alveolar apresentaram valores estati sti camente superiores às mesmas medidas em T1 (p<0,05). Conclusão: O aparelho ortodônti co removível superior é efeti vo nos casos de expansão lenta da maxila, agindo também indiretamente nas dimensões transversas do arco inferior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This classical way to manage product development processes for massive production seems to be changing: high pressure for cost reduction, higher quality standards, markets reaching for innovation lead to the necessity of new tools for development control. Into this, and learning from the automotive and aerospace industries factories from other segments are starting to understand and apply manufacturing and assembly oriented projects to ease the task of generate goods and from this obtain at least a part of the expected results. This paper is intended to demonstrate the applicability of the concepts of Concurrent Engineering and DFM/DFA (Design for Manufacturing and Assembly) in the development of products and parts for the White Goods industry in Brazil (major appliances as refrigerators, cookers and washing machines), showing one case concerning the development and releasing of a component. Finally is demonstrated in a short term how was reached a solution that could provide cost savings and reduction on the time to delivery using those techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this report, we present a case of myositis ossificans traumatica (MOT) of the medial pterygoid muscle that had developed after mandibular block anesthesia administered for endodontic treatment of the lower right second molar, demonstrating typical features of this condition. MOT should be considered as a differential diagnosis when there is severe limitation of jaw opening and an associated trauma. Panoramic radiographs and axial and coronal computed tomography (CT) scans can effectively delineate the calcified mass. Other imaging studies that may be helpful include magnetic resonance imaging (MRI), bone scans, and ultrasound. As shown in our case, calcified masses were found in the right mandibular angle, which severely limited jaw opening. Some earlier reported cases of MOT were treated by extraoral surgical approaches with complete removal of the evolving muscle. The aim of this case report is to present only the diagnostic imaging aspects of myositis ossificans traumatica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the influence of construction bite in the dentoskeletal changes induced by Klammt Appliance. Methods: The sample consisted of 17 children, with Class II malocclusion and initial mean age of 8.5 years. The construction bite was obtained using an Exactobite on edge-toedge anteroposterior relationship with 3 mm interincisal clearance. The height of the acrylic was determined by initial overbite associated to interincisal clearance and measured with digital caliper. The amount of advancement was obtained and measured by initial overjet in the lateral radiography. Pearson's correlation, linear regression and ANOVA were used to determine the relationship between dentoskeletal and construction bite variables. Results: The increase in the height of the acrylic promotes a greater inhibition of the forward displacement of the nasal spine and reduction in the facial growth index. The increase in the mandibular advancement induces more downward displacement of nasal spine and pogonion; a counter-clockwise rotation of palatine plane; an increase in mandibular length, maxillary alveolar height and interincisal angle; a decrease in mandibular alveolar height, the intermaxillary discrepancy and overjet; and palatal tipping of upper incisors. Conclusions: The different dimensions of the construction bite influence the dentoskeletal changes induced by the appliance in Class II treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maxillomandibular reconstructions are traditionally performed by means of autogenous bone grafts collected from intraoral donor areas and extraoral donor areas such as clavicle, iliac bone, rib, and tibia. The calvarial bone has been studied as an alternative donor area, with a low incidence of complications and minimal postoperative morbidity. Complications such as dural lacerations associated with cerebrospinal fluid leakage and extradural and subdural bleeding were minimized due to the use of surgical trepan, allowing the diploic layer delimitation before the osteotomy, preserving the internal calvarial cortical. The purpose of this article is to suggest a new technique for the obtainment of calvarial bone grafts with surgical trepan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Capão Bonito Granitic Massif is situated in the south portion of the São Paulo State and represents an elongate body with general direction NE-SW, intrusive in epimetamorphic rocks of Açungui Group (Votuverava Formation), and in granitic rocks of the Três Córregos Complex. It is partially covered by sedimentary rocks of the Paraná Basin (Itararé Group). As the chief type we have red sienogranite, holo to leucocratic with biotite and rare hornblende, inequigranular with medium to coarse grains to porphiritic and isotropic to slightly cataclastic textures of marginal zones. This granite was analyzed for petrographics (composition, structure and texture), chemical composition (major elements), physical and mechanical (water absorption, resistance to abrasion, impact of hard body and efforts of compression and traction) and chemical attack aspects. The results were compared to suggested values for granitic rocks used for ornamental purposes. The whole massif shows compositional, textural, structural (related to isotropy) and chemical (major elements) characteristics very homogeneous. The varieties of sienogranite named commercially as Capão Bonito or Rubi Red Granite showed results very similar to each other, with some variations in the physical and mechanical resistance resulting of the penetrative brittle deformation of regional occurrence, evidenced by differences in the microfissural index.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the study was to evaluate mechanical behavior of implants inserted in three substrates, by measuring the pullout strength and the relative stiffness. 32 implants (Master Porous-Conexao, cylindrical, external hexagon, and surface treatment) were divided into 4 groups (n = 8): pig rib bone, polyurethane Synbone, polyurethane Nacional 40 PCF, and pinus wood. Implants were installed with the exact distance of 5 mm of another implant. The insertion torque (N·cm) was quantified using the digital Kratos torque meter and the pullout test (N) was performed by an axial traction force toward the long axis of the implant (2 min/mm) through mount implant devices attached to a piece adapted to a load cell of 200 Kg of a universal testing machine (Emic DL10000). Data of insertion torque and maximum pullout force were submitted to one-way ANOVA and Bonferroni tests (α = 0.05). Polyurethane Nacional 40 PCF and pinus wood showed the highest values of insertion torque and pullout force, with significant statistical difference (P < 0.05) with other groups. The analysis showed stiffness materials with the highest values for primary stability. © 2013 Nathalia Ferraz Oliscovicz et al.