140 resultados para Evaluation methods for image segmentation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The methodology for fracture analysis of polymeric composites with scanning electron microscopes (SEM) is still under discussion. Many authors prefer to use sputter coating with a conductive material instead of applying low-voltage (LV) or variable-pressure (VP) methods, which preserves the original surfaces. The present work examines the effects of sputter coating with 25 nm of gold on the topography of carbon-epoxy composites fracture surfaces, using an atomic force microscope. Also, the influence of SEM imaging parameters on fractal measurements is evaluated for the VP-SEM and LV-SEM methods. It was observed that topographic measurements were not significantly affected by the gold coating at tested scale. Moreover, changes on SEM setup leads to nonlinear outcome on texture parameters, such as fractal dimension and entropy values. For VP-SEM or LV-SEM, fractal dimension and entropy values did not present any evident relation with image quality parameters, but the resolution must be optimized with imaging setup, accompanied by charge neutralization. © Wiley Periodicals, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to compare-using cephalometric analysis (McNamara, and Legan and Burstone)-prediction tracings performed using three different methods, that is, manual and using the Dentofacial Planner Plus and Dolphin Image computer programs, with postoperative outcomes. Pre- and postoperative (6 months after surgery) lateral cephalometric radiographs were selected from 25 long-faced patients treated with combined surgery. Prediction tracings were made with each method and compared cephalometrically with the postoperative results. This protocol was repeated once more for method error evaluation. Statistical analysis was made by ANOVA and the Tukey test. The results showed superior predictability when the manual method was applied (50% similarity to postoperative results), followed by Dentofacial Planner Plus (31.2%) and Dolphin Image (18.8%). The experimental condition suggests that the manual method provides greater accuracy, although the predictability of the digital methods proved quite satisfactory. © 2013 World Federation of Orthodontists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Countries have different official programs and implement different sampling methods for the detection of Salmonella on poultry carcasses. In Brazil, a 25-g sample of skin and muscle excision (SME) from the wings, neck, and pericloacal parts is used; in the European Union (EU), a 25-g sample of neck skin (NSE) is used; and, in the United States, the whole carcass is rinsed with 400 ml of diluent (WCR). In the present study, these methods were evaluated to compare Salmonella occurrence and counts of hygiene indicator microorganisms (Escherichia coli, Enterobacteriaceae, and total viable count of aerobic mesophilic bacteria) using different carcasses from the same flock and also using different analytical units taken from the same carcass. Eighty flocks, with four broiler carcasses from each, were included in this study; three broilers were sampled according to protocols from Brazil, the EU, and the United States, and the last one by all three methods. SME, NSE, and WCR provided equivalent results (P > 0.05) for Salmonella detection on broiler carcasses when using different carcasses from the same flock and when using the same carcass. The predominant serovar was Salmonella Enteritidis. For the enumeration of hygiene indicator microorganisms, WRC provided higher counts than SME or NSE (P < 0.05), when using both the same or different carcasses. Therefore, it is possible to directly compare Salmonella results in poultry carcasses when using the methods recommended by the legislative bodies of Brazil, the United States, and the EU. However, WCR provides the best results for hygiene indicator microorganisms. Copyright © International Association for Food Protection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to compare by means of McNamara as well as Legan and Burstone's cephalometric analyses, both manual and digitized (by Dentofacial Planner Plus and Dolphin Image software) prediction tracings to post-surgical results. METHODS: Pre and post-surgical teleradiographs (6 months) of 25 long face patients subjected to combined orthognathic surgery were selected. Manual and computerized prediction tracings of each patient were performed and cephalometrically compared to post-surgical outcomes. This protocol was repeated in order to evaluate the method error and statistical evaluation was conducted by means of analysis of variance and Tukey's test. RESULTS: A higher frequency of cephalometric variables, which were not statistically different from the actual post-surgical results for the manual method, was observed. It was followed by DFPlus and Dolphin software; in which similar cephalometric values for most variables were observed. CONCLUSION: It was concluded that the manual method seemed more reliable, although the predictability of the evaluated methods (computerized and manual) proved to be reasonably satisfactory and similar.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. The aim of this clinical study was to determine the efficacy of Uncaria tomentosa (cat's claw) against denture stomatitis (DS).Study Design. Fifty patients with DS were randomly assigned into 3 groups to receive 2% miconazole, placebo, or 2% U tomentosa gel. DS level was recorded immediately, after 1 week of treatment, and 1 week after treatment. The clinical effectiveness of each treatment was measured using Newton's criteria. Mycologic samples from palatal mucosa and prosthesis were obtained to determinate colony forming units per milliliter (CFU/mL) and fungal identification at each evaluation period.Results. Candida species were identified with HiCrome Candida and API 20C AUX biochemical test. DS severity decreased in all groups (P < .05). A significant reduction in number of CFU/mL after 1 week (P < .05) was observed for all groups and remained after 14 days (P > .05). C albicans was the most prevalent microorganism before treatment, followed by C tropicalis, C glabrata, and C krusei, regardless of the group and time evaluated. U tomentosa gel had the same effect as 2% miconazole gel.Conclusions. U tomentosa gel is an effective topical adjuvant treatment for denture stomatitis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Huge image collections are becoming available lately. In this scenario, the use of Content-Based Image Retrieval (CBIR) systems has emerged as a promising approach to support image searches. The objective of CBIR systems is to retrieve the most similar images in a collection, given a query image, by taking into account image visual properties such as texture, color, and shape. In these systems, the effectiveness of the retrieval process depends heavily on the accuracy of ranking approaches. Recently, re-ranking approaches have been proposed to improve the effectiveness of CBIR systems by taking into account the relationships among images. The re-ranking approaches consider the relationships among all images in a given dataset. These approaches typically demands a huge amount of computational power, which hampers its use in practical situations. On the other hand, these methods can be massively parallelized. In this paper, we propose to speedup the computation of the RL-Sim algorithm, a recently proposed image re-ranking approach, by using the computational power of Graphics Processing Units (GPU). GPUs are emerging as relatively inexpensive parallel processors that are becoming available on a wide range of computer systems. We address the image re-ranking performance challenges by proposing a parallel solution designed to fit the computational model of GPUs. We conducted an experimental evaluation considering different implementations and devices. Experimental results demonstrate that significant performance gains can be obtained. Our approach achieves speedups of 7x from serial implementation considering the overall algorithm and up to 36x on its core steps.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To compare with pristine sites bone resorption and soft tissue adaptation at implants placed immediately into extraction sockets (IPIES) in conjunction with deproteinized bovine bone mineral (DBBM) particles and a collagen membrane.Material and methods: The mesial root of the third premolar in the left side of the mandible was endodontically treated (Test). Flaps were elevated, the tooth hemi-sectioned, and the distal root removed to allow the immediate installation of an implant into the extraction socket in a lingual position. DBBM particles were placed into the defect and on the outer contour of the buccal bony ridge, concomitantly with the placement of a collagen membrane. A non-submerged healing was allowed. The premolar on the right side of the mandible was left in situ (control). Ground sections from the center of the implant as well as from the center of the distal root of the third premolar of the opposite side of the mandible were obtained. The histological image from the implant site was superimposed to that of the contralateral pristine distal alveolus, and dimensional variation evaluated for the hard tissue and the alveolar ridge.Results: After 3 months of healing, both histological and photographic evaluation revealed a reduction of hard and soft tissue dimensions.Conclusion: The contour augmentation performed with DBBM particles and a collagen membrane at the buccal aspects of implants placed IPIES was not able to maintain the tissue volume.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study was to present a systematized review of different methods used to evaluate the masticatory efficiency in conventional complete denture wearers. A survey was conducted in the databases PubMed, Scopus, and Cochrane, seeking scientific articles according to the previously selected terms: "Masticatory performance", "Masticatory efficiency" and "Chewing ability complete denture". Moreover, complementary studies have been carried out with library manual search/databases, which included studies related to different ways to assess masticatory efficiency, specifically as it related to conventional complete denture wearers. Forty three papers were selected to be used in the present review. Despite the wide variety of methodologies in the literature, the sieves method is currently considered the gold standard method to evaluation of conventional complete denture wearers masticatory efficiency, since it is the simplest, does not depend on specific devices (beyond the set of sieves), allows for a rational assessment, and it has been widely reproduced in various types of oral rehabilitation. More, the almond, as natural test food, and the optocal (made from the molding material Optosil), as artificial test food, are the most constantly employed test foods to evaluate masticatory efficiency.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Angiogenesis involves many mediators including integrins, and the tripeptide RGD is a target amino acid recognition sequence for many of them. Hindlimb ischemia is a simple and convenient animal model however standardization of the injection procedures in the devascularized and control limb is lacking, thus rendering difficult the interpretation of results. The aim of this investigations was to evaluate neovascularization in a hindlimb murine model by means of 99mTc-HYNIC-ß-Ala-RGD. Methods: 99mTc-HYNIC-RGD analog was prepared using coligands. Ischemia was induced in Wistar rats by double- ligation of the common femoral artery. Radiolabeled RGD was injected after 2h, as well as 1, 3, 5, 7, 10 and 14 days. Uptake was evaluated by planar imaging and biodistribution studies. Results: The highest ratio between ischemia and control was achieved at the 7th day (2.62 ± 0.95), with substantial decrease by the 14th day. For pertechnetate the 7th day ratio was 0.87 ± 0.23. Scintigraphic image confirmed different uptakes. Conclusion: 99mTc-HYNIC-RGD analog concentrated in ischemic tissue by the time of widespread angiogenesis and pertechnetate confirmed reduction in blood flow. In this sense, the protocol can be recommended for ischemic models.