145 resultados para Dispositivos de retenção
Resumo:
The polemical discussion between orthodontic therapeutic and surgical approaches with relation to borderline cases receives a new impulse with the emergence of temporary anchorage devices. This branch of Orthodontics has brought new treatment perspectives, but it has still been applied empirically, while the various factors involved in determining and conducting the treatment planning are neglected. The objective of the present study is to identify the several factors to be considered in both forms of treatment in order to provide the orthodontist with information that may contribute for the correct decision.
Resumo:
Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Visualização da informação colaborativa por meio de um ambiente multiprojetado e dispositivos móveis
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
Sabendo-se do potencial de toxicidade do mercúrio, mais especificamente de sua forma orgânica, o metilmercúrio (MeHg), faz-se necessária a busca por métodos analíticos eficientes e precisos para a determinação e especiação do metal. A técnica de difusão por gradiente em filmes finos (DGT) já vem sendo utilizada para tal fim de maneira eficiente tendo apresentado resultados satisfatórios em diversos estudos. Porém, a utilização de ligantes alternativos aos convencionais, que tornem a aplicação da técnica menos custosa em termos laborais e financeiros, faz-se importante para um monitoramento constante e eficiente do metilmercúrio no ambiente. No presente trabalho buscou-se avaliar o potencial da levedura Saccharomyces cerevisiae imobilizada em agarose em combinação com a poliacrilamida como agente difusivo para determinação seletiva de MeHg. Os resultados demonstraram-se positivo, com um coeficiente de difusão médio de 7,03 ± 0,77 x 10-6 cm2 s-1. Os resultados demonstraram também baixa influencia do pH, força iônica e outros íons na retenção do analito pelos dispositivos. As recuperações de Hg2+ demonstraram-se insatisfatórios, evidenciando a seletividade dos dispositivos
Resumo:
Despite the great development of organic and polymeric electroluminescent materials, the large scale commercial application of devices made with these materials seems conditioned to specific cases, mainly due to the high cost and the low durability, in compared to conventional technologies. In this study was produced electroluminescent devices by a process simple, drop casting. Were produced electroluminescent films containing Zn2SiO4:Mn immersed in a conductive polymer blend with different thicknesses. The morphological characteristics of these films were studied by scanning electronic microscopy. These films were used in the manufacture of electroluminescent devices, in which the light emission properties of the developed material were evaluated. The blend was composed of the conductive polymer Poly(o-methoxyaniline), doped with p-toluene sulfonic acid, and an insulating polymer, Poly(vinylidene fluoride) and its copolymer Poly(vinylidene fluoride-cotrifluoroethylene). To this blend was added Zn2SiO4:Mn, thereby forming the composite. A first set of devices was obtained using composites with different weight fraction of polymeric and inorganic phases, which were deposited by drop casting over ITO substrates. Upper electrodes of aluminum were deposited by thermal evaporation. The resulting device architecture was a sandwich type structure ITO/ composite/ Al. A second set of devices was obtained as self-sustaining films using the best composite composition obtained for the device of the first set. ITO electrodes were deposited by RF-Sputtering, in both faces of these films. The AC electrical characterization of the devices was made with impedance spectroscopy measurements, and the DC electrical characterization was performed using a source/ meter unit Keithley 2410. The devices light emission was measured using a photodiode coupled to a digital electrometer, Keithley 6517A. The devices electrooptical characterization showed that the...
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Agronomia (Agricultura) - FCA
Resumo:
This work shows the preparation and characterization of the new nanocomposites based on fibroin and biocellulose. Bacterial cellulose (BC) is an exopolysaccharide produced by bacteria of the genus Gluconacetobacter, which it has identical chemical structure of the cellulose from plants and it has gained attention in the field of research for its unique properties as excellent mechanical properties when dry and hydrated , higher capacity of water retention, moldability , biodegradability and excellent biological affinity . Silk fibroin (SF) is a structural protein present in the cocoon of the silkworm, Bombyx mori, has been identified as suitable for developing optical devices, tissue engineering application, enzyme immobilization, controlled release drug agent biopolymer. Silk fibroin/bacterial cellulose nanocomposite films were prepared impregnating different cellulose charges (0.5 %, 1.0 %, 1.5 %, 2.5 %, 5.0 % and 10.0 %) weight/weight. According mechanical tests and water and Paynes's cup permeability showed that SF/BC 1% nanocomposite has the most relevant results. Poliethylenoglicol (PEG) containing SF films improved optical and mechanical properties when compared to pristine SF film. New SF/BC nanocomposites could be applied in Medicine, as biodegradable packaging and flexible substrates for OLEDs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Teeth that have lost much of their coronal tooth structure need intraradical devices to achieve a desired retention of the restorative material, restoring aesthetics and function to the patient. For this purpose, various types of intracanal posts have been studied, of wich the fiber posts have been highlighted with its increasing use in the dental market. The purpose of this study was to present a clinical case of using fiberglass post. As well as critically analyze the published works and points of controversy described by different authors related to factors such as different protocols cementation, surface treatments pins, fracture toughness and compression, the possibility of microleakage, diameter and length of the pin, and the various materials used in conjunction with the intracanal retainers. Thus, we concluded that fiber posts showed as an excellent alternative for anterior teeth, since have least 2 mm of tooth remaining.
Resumo:
The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.
Resumo:
The treatment with overdenture supported by tooth consists in complete or partial removable prosthesis confection in which some satisfactory tooth are maintained and used to aiding retention associated with any retention system. The purpose of this case report is to show the use of magnet attachment in the confection overdenture to improve the oral rehabilitation in cases with restricted intermaxillary space. The treatment was considered successful by the patient and no need for excessive alteration in the prosthesis was required in the follow-up period of 6 months.
Resumo:
Objective: to the purpose of this study was to compare the stress distribution in the peri-implant hard tissue on different attachment systems for mandibular or maxillary implant-retained overdentures. Material and methods: the search for published studies was performed on PubMed/Medline database covering the period of January 2000 to April 2014. The selection of the eligible studies was performed according to including and excluding criteria. Results: a total of 140 studies were screened and according to the search strategy, 21 studies were selected for this review. Eight studies perfomed strain-gauge analysis, 5 evaluated the stress distribution though photoelastic test and 7 performed tridimensional finite element analysis. Only one study in vivo was included. Non-splinted O-rings showed better stress distribution than other bar-clip attachment systems. Conclusions: the present study did not find sufficient evidences regarding the most indicated attachment system for overdentures with better stress distribution for the peri-implant hard tissue. The methodologies analyzed should be complemented with other tests and used as a tool for further clinical studies.