258 resultados para Dentures.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to evaluate the presence of TMD (temporomandibular disorder), dissatisfaction related to the use of removable partial dentures (RPD) and the effect of the treatment on temporomandibular joint noises, 13 female patients with Kennedy class I and II mandibular arch were selected. Another 13 young, asymptomatic, dentate patients, also female, were used as reference. After four years, 38.4% were found to have a moderate or severe degree of TMD. Over the four years, the degree of TMD increased in 46.15% of the patients, was not affected in 20.07%, while in 15.38% it decreased or the patients remained free from signs and symptoms. About 30% of the patients at the second year and 46% after the fourth year, had complaints regarding retention and stability. It was concluded that there is no relationship between TMD and the condition of partially edentulous Kennedy class I and II, but patient dissatisfaction increased after the second year and temporomandibular joint noise was reduced significantly with the replacement of the teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined by means of scanning electron microscopy (SEM), the attachment of Streptococcus mutans and the corrosion of cast commercially pure titanium, used in dental dentures. The sample discs were cast in commercially pure titanium using the vacuum-pressure machine (Rematitan System). The surfaces of each metal were ground and polished with sandpaper (#300-4000) and alumina paste (0.3 μm). The roughness of the surface (Ra) was measured using the Surfcorder rugosimeter SE 1700. Four coupons were inserted separately into Falcon tubes contained Mueller Hinton broth inoculated with S. mutans ATCC 25175 (109 cuf) and incubated at 37 °C. The culture medium was changed every three days during a 365-day period, after which the falcons were prepared for observations by SEM. The mean Ra value of CP Ti was 0.1527 μm. After S. mutans biofilm removal, pits of corrosion were observed. Despite the low roughness, S. mutans attachment and biofilm formation was observed, which induced a surface corrosion of the cast pure titanium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and rive men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to use photoelastic models to analyze the distribution of stress caused by the incidence of loads on a mandibular distal extension removable partial denture, both on the abutment teeth and on differently shaped residual ridges: distal ascending, descending-ascending, horizontal and distal descending. The best type of retainer and location of the rest on the last abutment tooth were determined for the different types of ridge. Four models were made from photoelastic resin (PL-1 for the teeth and PL-2 for the alveolar ridge), one for each kind of ridge. For each model, 4 removable partial dentures (RPD) were made (16 RPD altogether): T-bar retainer and distal rest, T-bar retainer and mesial rest, circumferential retainer and distal rest, and circumferential retainer and mesial rest. The models were placed on a circular polariscope and a 100 N axial load (point load) was applied to premolars and molars of the RPD. The formation of photoelastic bands was photographed for qualitative analysis. Results showed that the horizontal ridge had better distribution of stress, while the distal descending ridge had greater concentration of stress. The circumferential retainer had greater areas of stress for all types of ridges except the horizontal ridge, where there was no influence related to retainer type. The distribution of stress was similar among the different types of ridges when the rest was mesial or distal to the last abutment tooth, except for the distal descending ridge, where there was greater concentration of stress when the rest was located distally to the last abutment tooth. Thus, it may be concluded that (1) the situation was least favorable for the distal descending ridge and most favorable for the horizontal ridge, (2) the T-bar retainer had more favorable stress distribution, except when the ridge was horizontal, in which case there was no influence in relation to the type of retainer, (3) the location of the rest showed similar behavior in all except the distal descending ridge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the clinical efficacy of Schinus terebinthifolius Raddi (aroeira) tincture in the treatment of denture stomatitis. Method: Eighteen removable denture wearers with clinical diagnosis of type II denture stomatts and presence of candidosis associated to the denture use, as confirmed by clinical and mycological examinations, were selected for the study. The patients were allocated to two groups: TG (test group) - treatment with Schinus terebinthifolius Raddi (aroeira) tincture; CG (control group), treatment with nystatin. All patients were instructed to clean the dentures with toothbrush and dentifrice, and then apply the product on the palatal mucosa and on denture surface 3 times a day, during 15 consecutive days, removing the denture at bedtime and keeping it in a receptacle with water. At the 15th day of use, the clinical and mycological examinations were redone to evaluate treatment efficacy. Data were analyzed statistically by Wilcoxon and Mann-Whitney tests at 5% significance level. Results: The inflammatory process and Candida spp. infect on were eliminated in 66.7% and 77.8% of the cases, respectively, in TG. In CG, elimination of the inflammatory process and fungal infect on occurred in 77.8% and 88.9% of the cases, respectively. These results were statistically significant (p=0.01). There was no statistically significant difference between the treatments (p>0.05). In all cases, fungal infect on was detected only on the denture, and C. albicans was the most prevalent microorganism, being present in 94.4% of the cases. Conclusion: The treatment with Schinus terebinthifolius Raddi (aroeira) tincture was effective in the treatment of denture stomatitis, promoting remission of the inflammatory process and Candida spp infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of all-ceramic systems following metalceramics restorations allowed simulation of natural dentition due to favorable esthetics and resistance. In-Ceram is an alternative when esthetics is primordial as well as resistance required in rehabilitation. However, an ideal smile is associated to not only shape, color, texture and translucency but also harmony with gingival tissue. So, the aim of this study is to report a clinical case based on periodontal and fixed partial dentures principles to perform periodontal plastic surgery followed by esthetic rehabilitation. A female patient, 40-year-old, presented complaint about dental esthetics. After clinical and radiographic exams, metal-ceramics crowns (teeth 11, 12, 13, 21, 22 and 23) were considered unsatisfactory due to marginal leakage, color change in gingival tissue associated to metallic margin, and gummy smile. So, a crown lengthening surgery of anterior teeth was performed followed by rehabilitation of superior teeth with In-Ceram single crowns. Clinical significance: The interaction between periodontics and fixed prosthodontic area is the key of an adequated treatment planning which involves gingival smile to provide function and an esthetic condition in association with an esthetic, resistant and predictable material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water may influence the mechanical properties of the acrylic resins. Thus, the effect of water storage on the impact strength (IS) of one denture base (Lucitone 550 - L) and four reline resins (Tokuyama Rebase II - T; UfiGel Hard - U; Kooliner - K; New Truliner - NT) was evaluated. Bars of L were made (60 x 6 x 2 mm) and relined (2 mm) with T, U, K, NT and L. Intact specimens of each material (60 x 6 x 4 mm) were also fabricated for comparative purposes. Specimens were submitted to Charpy impact tests without water storage (control) and after immersion in water for 7, 90 and 180 days. Data (kJ/m 2) analyzed by two-way ANOVA and Tukey's test (p=0.05) revealed that after 90 days, U exhibited an increase in the IS (0.93) compared to 7 days (0.58). K (1.48) and L/K (7.21) exhibited a decrease at the 7-day period (1.01 and 3.23, respectively). NT (0.60) showed an increase in the IS after 180 days (1.52), whereas L/ NT (7.70) showed a decrease (3.17). Water immersion improved the IS of U and NT, and decreased the IS of K, L/K, and L/NT. Water may affect differently the IS of acrylic resins and, consequently, the resistance to fracture of relined denture bases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The prevalence of wearing and fracture of complete dentures was evaluated among edentulous patients treated in two dental schools in Brazil. Background: Acceptance and wearing of complete dentures are related to adaptive behaviour of edentulous patients. However, one reason that could interfere with the wearing dentures is their potential to fracture, which is still a common complication in denture rehabilitation practice. Material and methods: Two hundred and twenty-four edentulous patients rehabilitated with complete dentures from 2000 to 2005 in Araçatuba and Araraquara Dental School, University of State of São Paulo, were assessed in 2006 and 2007 to answer a questionnaire about wearing and fracture of their dentures. Statistical analysis were performed using Epi Info software and chi-squared test to compare maxillary and mandibular data (α = 0.05). Results: Almost 26% of the patients did not wear their dentures, and among the remainder, the majority wore the maxillary denture. About 30% of the dentures were fractured, with higher prevalence in the maxillary arch (p = 0.003). Conclusions: Discontinuation of wearing dentures was quite high, especially considering the treatment which was carried out in university clinics. Prevalence of fractures was also high, greater for the maxillary denture, and was one of the main reasons for non-wearing of complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the stress distribution in mandibular free-end removable partial dentures (RPD) associated with FPD in the abutment teeth considering different inclinations of the residual ridge: (1) horizontal and (2) distal descending ridges and two designs of free-end RPD with different attachment systems were tested: (1) clasp and (2) system ERA. Methods. Axial loads (100 N) were applied on the teeth of the RPD. The images were recorded and the stress distribution was evaluated through photoelastic fringes. Results. In general, the distal descending ridge presented more photoelastic fringes in the region of the roots of the abutment teeth while the horizontal ridge exhibited higher compression in the base of the prosthesis. In the horizontal ridge, the denture with clasp presented more favourable stress distribution than the denture with the system ERA. In the distal descending ridge, the denture with the system ERA relieved the region of the abutment teeth and overloaded the residual ridge. Conclusion: The horizontal ridge presented more favourable performance; the dentures with clasp exhibited better performance for both ridges evaluated; the denture with the system ERA presented better results in the distal descending ridge. © 2013 Informa Healthcare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning. © 2013 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effect of diamond-like carbon thin films doped and undoped with silver nanoparticles coating poly(methyl methacrylate) (PMMA) on Candida albicans biofilm formation. The control of biofilm formation is important to prevent oral diseases in denture users. Materials and Methods: Forty-five PMMA disks were obtained, finished, cleaned in an ultrasonic bath, and divided into three groups: Gc, no surface coating (control group); Gdlc, coated with diamond-like carbon film; and Gag, coated with diamond-like carbon film doped with silver nanoparticles. The films were deposited using a reactive magnetron sputtering system (physical vapor deposition process). The specimens were characterized by optical profilometry, atomic force microscopy, and Rutherford backscattering spectroscopy analyses that determined differences in chemical composition and morphological structure. Following sterilization of the specimens by γ-ray irradiation, C. albicans (ATCC 18804) biofilms were formed by immersion in 2 ml of Sabouraud dextrose broth inoculated with a standardized fungal suspension. After 24 hours, the number of colony forming units (cfu) per specimen was counted. Data concerning biofilm formation were analyzed using ANOVA and the Tukey test (p < 0.05). Results: C. albicans biofilm formation was significantly influenced by the films (p < 0.00001), reducing the number of cfu, while not affecting the roughness parameters (p > 0.05). The Tukey test showed no significant difference between Gdlc and Gag. Films deposited were extremely thin (∼50 nm). The silver particles presented a diameter between 60 and 120 nm and regular distribution throughout the film surface (to Gag). Conclusion: Diamond-like carbon films, doped or undoped with silver nanoparticles, coating the base of PMMA-based dentures could be an alternative procedure for preventing candidosis in denture users. © 2013 by the American College of Prosthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)