418 resultados para Cimentos compósitos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 days

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOAR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O sucesso das restaurações metálicas indiretas depende, dentre outros fatores, de uma união eficaz entre a estrutura metálica e o cimento dentário empregados. Sabe-se que os primers para metal atuam com comprovada eficácia na resistência adesiva dos cimentos resinosos às ligas nobres. Entretanto, pouco foi estudado sobre o efeito de tais materiais em ligas não nobres. O propósito deste estudo foi avaliar a eficácia de primers para metal na resistência ao cisalhamento da união entre cimentos resinosos e metais não nobres. Discos (9 mm de diâmetro e 3 mm de altura) foram fundidos em liga de NiCr (n=80) e em titânio comercialmente puro (Ti c.p.) (n=80) e foram incluídos em anel de PVC com resina acrílica quimicamente ativada. As superfícies dos discos foram regularizadas com lixas de carbeto de silício de granulação 320, 400 e 600 e jateadas com partículas de óxido de alumínio de 50 µm. Espécimes de cada metal foram divididos em quatro grupos (n=20). Uma matriz metálica bi-partida (5 mm de diâmetro interno e 2 mm de altura) foi posicionada na superfície do espécime. As áreas adesivas receberam um dos seguintes tratamentos: 1) Panavia F; 2) Alloy Primer e Panavia F; 3) Bistite DC e 4) Metaltite e Bistite DC. Para evitar a exposição dos cimentos à luz, estes foram espatulados e inseridos na matriz dentro de uma câmara de revelação radiográfica. Quarenta minutos após a confecção, os espécimes foram armazenados em água destilada a 37ºC por 24 horas e então termociclados (1.000 ciclos, 5ºC e 55ºC, 30 segundos cada banho). Após a termociclagem, os espécimes foram armazenados novamente nas mesmas condições descritas anteriormente por um período de 24 horas (n=10) ou de 6 meses (n=10) antes do ensaio de cisalhamento em uma máquina de ensaios mecânicos (Material Test System 810).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: O presente trabalho, dividido em três estudos, teve como objetivo geral identificar e quantificar a liberação de componentes e avaliar a citotoxicidade e a biocompatibilidade de cimentos de ionômero de vidro (CIVs). Método: Para o estudo 1, extratos dos CIVs Vitrebond (VB), Fuji Lining LC (FL), Vitremer (VM), Fuji II LC (FII), Ketac Fil Plus (KF) e Ketac Molar Easymix (KM) foram obtidos pela imersão de corpos-de-prova em meio de cultura celular (DMEM). Esses extratos (n=9 por grupo) foram analisados por eletrodo específico quanto à presença de flúor e por espectrometria de absorção atômica quanto à presença de alumínio e zinco. HEMA e iodobenzeno foram identificados por CG/EM (n=6). Para o estudo 2, células MDPC-23 foram colocadas em contato com os extratos dos CIVs por 24 horas. Em seguida, foram avaliadas a atividade da desidrogenase succínica (SDH) (n=8), a produção de proteína total (PT) (n=8), a atividade da fosfatase alcalina (FAL) (n=8) e a morfologia celular (n=2). Para o estudo 3, tubos de polietileno (n=24 por grupo) foram preenchidos com os CIVs e implantados no tecido subcutâneo de 42 ratos. Como grupo controle foi utilizada a guta-percha. Após 7 ou 15 dias de pós-operatório, metade dos espécimes de cada grupo e período (n=6) foi preparada para análise histológica, e os demais (n=6) para análise da expressão de genes que codificam para IL-1? e TNF-?. Resultados: Os extratos de todos os CIVs apresentaram uma concentração de flúor significativamente maior do que o meio de cultura DMEM (controle), tendo o VB liberado maior quantidade, estatisticamente significante, do que os demais CIVs. O VB foi, também, o único material que liberou quantidades relativamente altas de alumínio e de zinco. O HEMA foi identificado nos extratos de todos os CIVs modificados por resina (VB, FL, VM e FII), e o iodobenzeno... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o pH e a densidade óptica das soluções de azul de metileno a 1% e 2% (tamponadas e não tamponadas) após a imersão de três cimentos endodônticos. Foram preparados oitenta espécimes de cada cimento endodôntico (Endofill, AH Plus e Sealapex), os quais foram imersos nas soluções corantes. As soluções foram analisadas antes e após a imersão dos materiais nos períodos de tempo de 0, 24, 48 e 72h. Foram realizadas avaliações do pH utilizando um pHmetro e da densidade óptica utilizando um espectofotômetro ajustado em 596nm. Os dados de pH foram analisados através de estatística descritiva e os dados da densidade óptica foram analisados pela ANOVA e teste de Tukey 5%. Pôde-se verificar que as soluções corantes de azul de metileno tamponadas e não tamponadas apresentaram pequena variação nos valores de pH e densidade óptica antes do contato com os cimentos endodônticos. As soluções corantes não tamponadas apresentaram valores de pH menores que as tamponadas, independentemente do contato com qualquer cimento endodôntico. Os cimentos endodônticos promoveram alterações nos valores de pH das soluções corantes, sendo que as maiores alterações ocorreram nas soluções não tamponadas. Ocorreram alterações nos valores da densidade óptica das soluções corantes tamponadas e não tamponadas nos diferentes períodos de tempo de análise, sendo diferentes para cada cimento endodôntico utilizado

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fracture surfaces express the sequence of events of energy release due to crack propagation by linking the relief of the fracture to the loading stresses. This study aims to evaluate the heterogeneity of the critical zone for the advancement of the crack along its entire length in a thermoset composite carbon fiber and epoxy matrix, fractured in DCB testing (Double Cantilever Beam) and ENF (End-Notched Flexure). Investigations were made from image stacks obtained by optical reflection of extended depth from focus reconstruction. The program NIH Image J was used to obtain elevation map and fully focused images of the fracture surface, whose topographies were quantitatively analyzed. The monofractal behavior for DCB samples was assessed as being heterogeneous along the crack front and along the crack for all the conditionings. For the samples fractured in ENF test, there was a strong positive correlation to the natural condition, considering the fibers at 0° for the monofractal dimension and structural dimension (Df and Ds). For fibers at 90° to crack propagation, there was a moderate positive correlation for the textural dimension of natural condition. However, for the samples under ultraviolet condition and those subjected to thermal cycles, there was no correlation between the fractal dimension and fracture toughness in mode II

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years the aeronautic industries has increased investment in areas of technological research aiming at materials that offer better performance, safety, weight reduction and fuel consumption. For this reason the most studied materials are polymeric materials, due to their higher mechanical strength and higher stiffness. This work evaluated characteristics of two composite laminates produced from the same process, but they differed only in regions where the resin was injected and the vacuum position. The composite laminates were SC-79 resin reinforced with glass fiber fabric (plain weave) processed via VARTM. For this reason the material was subjected to mechanical tests such as: tensile, and fatigue following standards ASTM D 3039 and ASTM D 3479, respectively. The latter was observed the S-N curve. It was performed the ultrassonic C-scan analysis to check impregnation of the fiber. Considering that the process was the same for the two laminates, with small variations in the injection and in vacum ports, it was expected to find similar characteristics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combining the characteristics of good adhesion and sealing of the AH Plus sealer the biological properties of the MTA, zinc oxide and calcium hydroxide, the purpose of this study was to evaluate the cytotoxicity of these associations. The specimens of the sealers and their associations were mixed and exposure to culture medium (82.4 mm2surface/mL) after the manipulation and incubated in a humidified incubator (37°C and 100% humidity) for 24 h. Chinese hamster lung fibroblasts (V79) were exposed to different dilutions of this extracts for 24 h and cell viability was measured by MTT test. The differences between the cell survival rates were statistically analyzed for Kruskal-Wallis and Dunn (p≤0.05). All sealers showed a significant difference with the group control, except the MTA. Cytotoxicity with the control group increased in the following order: AH Plus < AH Plus + Ca(OH) 2 < AH Plus + OxZn< AH Plus + MTA < MTA (p≤ 0,05). It was concluded that the addition of biological materials in order to improve the consistency of AH Plus for use in retro cavities its toxicity has not decreased significantly

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concern with the environment preservation has done with that researchers as well as industries invest in the search for materials that come from renewable sources. Natural fibers, because they are ecologically correct and have low cost, have been studied as a possible substitute, even if partial, of synthetic fibers in the development of polymeric composites. In this context, the hybrid composites (natural/synthetic) increase considerably the range of application of natural composites. The auto industry, in its constant quest for good mechanical properties materials which are developed with sustainability, has in composites with hybrid reinforcement a very viable alternative. In the present work, the nature Crown pineapple fibers and nature Crown pineapple fibers treated with alkaline solution were studied in order to evaluate the influence of chemical treatment in its properties. For this techniques were used x-ray diffractometry, Thermogravimetry and Infrared Spectroscopy (FTIR). Composites have been developed using polypropylene, reinforced with pineapple fibers and pineapple fibers hybrids/glass fibres, both with levels of 5 and 10%. These composites were analyzed by Thermogravimetry techniques and tested by traction. The realization of this work indicated that although the chemical treatment did not affect the thermal stability of the fibers, caused an increase in crystallinity index fibers and decreased its hydrophilic. The tests performed on composite indicated that the composites process was suitable because it provided good dispersion of the polymer matrix. The addition of natural fibers from the pineapple's Crown, in a proportion of 10%, provided the greatest increase in modulus of elasticity (27%) when compared to the pure polymer

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the emergence of new filling materials with different properties and behaviors, the approach of endodontic treatment must be readjusted so that the appropriate result can be achieved. New endodontic sealers include methacrylate resin-based, plant resin-based and the evolution of epoxy-based sealers. This study verified the behavior of new materials that presents controversial results in the literature, about coronal bacterial leakage. That for, 56 single-rooted human teeth were prepared in the direction crown-apex and filled with gutta-percha points with taper of 4% using the single cone technique. Roots were divided randomly into 4 groups according to the sealer (Apexit Plus, AH Plus, EndoREZ and Polifil). After filling, the roots were incorporated in a leakage model, which upper chamber contained a suspension of Streptococcus mutans, and lower chamber a broth, leaving 3 mm of root apical portion immersed. Leakage was assessed for turbidity in lower chamber every day for 60 days. Survival analysis was performed using the nonparametric Kaplan- Meier method (p<0,05). All experimental groups presented leakage during the study’s period, however the maximum time achieve was 22 days. The medium time of leakage was: Apexit Plus 6,3 days, AH Plus 6,3 days and Polifil 5,1 days, but in EndoREZ all specimens infiltrated in the first day, presenting shorter capacity of impermeabilization compared to the other groups. Concluding that none of the sealers tested was able to prevent coronal bacterial leakage