143 resultados para Caracterização física


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mass spectrometry is a diagnosis that can aid in the understanding of the kinetics of chemical plasma environment. Through this you can get information about some species present in the environment and make inferences about the behavior of the plasma when parameters such as pressure and applied power changes. When analyzed plasmas generated by the discharge of argon and diglyme (both individually and mixtures of them in various proportions) could be found conditions in which the plasma behavior was different from what is often found in the literature. By the end some peculiar characteristics of plasmas generated by mixing argon / diglyme were raised and it was found that the noble gas is a good mediator of physical and chemical reactions that occur in the environment, and help in the understanding of chemical kinetics. Therefore mass spectrometry was shown highly important tool for the study of plasma environment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study area is the Garoupa Field, located 75 km from the coast of Rio de Janeiro in bathymetric elevation of 125 m and it is the first important offshore discovery of the Campos Basin with hydrocarbon production in the Albian carbonates. The high significance of carbonate rock reservoirs for the global oil industry and its degree of complexity, combined with the fact that the Garoupa Field is a mature field, make this research project interesting to develop a re-exploratory vision of the study area. The objective of this paper is to characterize the physical properties of the Macae Group reservoirs in the Garoupa Field through well correlation techniques, petrophysical analysis and seismic interpretation (3D), in order to evaluate qualitatively and quantitatively the response of geophysical data to the presence of carbonate rock reservoirs. From the analysis of well profiles (gamma ray, resistivity, density and sonic) it was possible to identify six reservoir levels in the Quissamã Formation. As a result, the reservoirs have good correlation between the wells in the Garoupa Field and show lateral facies variation. In the seismic interpretation, structural contour maps were generated in time (ms) from the top of the Macae Group and two horizons that correspond to the reservoir levels. These maps show that the oil producing area of this field is a structural high located at the west of the interpreted seismic cube, and it was classified as a rollover limited by lateral faults forming a horst. The seismic attribute maps show a good response to the reservoirs of the Garoupa Field because they are associated with amplitude anomalies, verified by the correlation between the physical properties of the reservoir rock and seismic data through cross plots, with emphasis in a linear correlation between the resistivity profile and the values of Maximum Absolute Amplitude and RMS Amplitude attributes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A combinação de polímeros com nanopartículas de metais nobres resultam na formação de filmes finos, que podem ser utilizado na fabricação de nanosensores. Esses filmes finos possuem propriedades exclusivas, que causam ressonância plasmônica de superfície pela mudança conformacional dos mesmos. Essa variação conformacional é causada pela interação com analito ou por estímulo externo, podendo ser analisada por espectroscopia de absorção na região do UV-vis. Este simples e econômico meio de transdução do sinal apresenta-se como uma ferramenta bastante promissora, e se combinado com a alta seletividade encontrada em reações biológicas, torna-se ainda mais promissora no desenvolvimento de sensores. Os esforços desse projeto foram concentrados para o desenvolvimento dos sensores que respondam a estímulos externo e baseado na utilização de polímeros escovas. Este trabalho de conclusão de curso foi baseada na produção de sensores nanoplasmônicos, que na presença de fatores externos causam modificação estrutural dos filmes finos poliméricos depositados sobre um substrato e dão um resposta altamente seletiva. As mudanças conduzirão à geração de sinais ópticos ou eletroquímico, que serão medidos por transmissão de ressonância plasmônica de superfície ou via eletroquímica. Foram realizados experimentos de voltametria cíclica e impedância eletroquímica em pH=3 para avaliar a capacidade de eletródica deste material. Também foram efetuados experimentos por espectrofotometria de absorção na região de ultravioleta-visível em pHs variando de 3 a 7 para se analisar o efeito plasmônico do material. Pode-se notar que em pH mais ácidos o polímero se mostrou mais condutor e de acordo com a literatura este efeito é causado pela expansão polimérica que deixa o mesmo em seu estado ativo ON (expandido). Já em pH mais básicos os polímeros demonstraram um comportamento inverso por os mesmo se contraem, ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Boron Neutron Capture Therapy (BNCT), based on the 10B(n,α)7Li reaction, represents a promising modality for the treatment of cancers that are resistents to conventional treatments. So, it is necessary to find drugs (boron compounds) with high selectivity for each type of cancer, the neutrons source should be well characterized and the rate of 10B(n,α)7Li reaction should be measured with great accuracy as possible. This study aimed to develop a method for manufacturing thin films of boron, for measure the 10B(n,α)7Li reaction, and analyze the uniformity of the films. Five thin films of boron were manufactured with three different concentrations of boric acid, heated to transform the acid in boron, irradiated with thermic neutrons coupled to CR-39 detectors, in BNCT line at the reactor IEA-R1 IPEN/CNEN, São Paulo. After the irradiation, the detectors were chemically attacked with NaOH to reveal the tracks. The methodology presented is effective because it resulted in deposition of boron as thin film enabling the quantitative analysis of 10B(n,α)7Li reaction. The analysis of the uniformity of density of the induced tracks in CR-39 shows that, in most of the films, there is no uniformity in surface distribution of boron, but when the film is divided, we obtain some uniform sectors

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The plasma represents a average of the information referring biochemists to the physiology of the organism as a whole, therefore it indirectly or directly interacts with all tissues of the body. In such a way the plasma can be considered as a metabolic “soup”. Using the Nuclear Magnetic Resonance Spectroscopy sanguineous plasma spectra had been generated and using deconvolution techniques it was possible to know the contribution of the albumin for the formation of the spectra of the sanguineous plasma

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the great development of organic and polymeric electroluminescent materials, the large scale commercial application of devices made with these materials seems conditioned to specific cases, mainly due to the high cost and the low durability, in compared to conventional technologies. In this study was produced electroluminescent devices by a process simple, drop casting. Were produced electroluminescent films containing Zn2SiO4:Mn immersed in a conductive polymer blend with different thicknesses. The morphological characteristics of these films were studied by scanning electronic microscopy. These films were used in the manufacture of electroluminescent devices, in which the light emission properties of the developed material were evaluated. The blend was composed of the conductive polymer Poly(o-methoxyaniline), doped with p-toluene sulfonic acid, and an insulating polymer, Poly(vinylidene fluoride) and its copolymer Poly(vinylidene fluoride-cotrifluoroethylene). To this blend was added Zn2SiO4:Mn, thereby forming the composite. A first set of devices was obtained using composites with different weight fraction of polymeric and inorganic phases, which were deposited by drop casting over ITO substrates. Upper electrodes of aluminum were deposited by thermal evaporation. The resulting device architecture was a sandwich type structure ITO/ composite/ Al. A second set of devices was obtained as self-sustaining films using the best composite composition obtained for the device of the first set. ITO electrodes were deposited by RF-Sputtering, in both faces of these films. The AC electrical characterization of the devices was made with impedance spectroscopy measurements, and the DC electrical characterization was performed using a source/ meter unit Keithley 2410. The devices light emission was measured using a photodiode coupled to a digital electrometer, Keithley 6517A. The devices electrooptical characterization showed that the...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Usually organic polymeric diodes are made with a semiconductor layer placed between two electrodes in a sandwich-like architecture, where the electrodes are deposited on the surfaces of a polymeric semiconductor film. This methodology leads to two main problems: i) the polymeric film top surface is rough and irregular, resulting in non-uniform electric field into the device; ii) during the deposition of metallic electrode in the top surface polymeric film, by thermal evaporation, occurs the diffusion of metal atoms into the polymeric film, changing the material electronic structure. Thus, the metal-semiconductor junction is not well defined, which is essential for the production of good quality Schottky diode, which exhibits ideality factor close to the unity and low turn-on voltage. In order to avoid these two problems, in the present research was proposed to manufacture an organic diode with the semiconductor polymeric layer deposited over bimetallic (gold and aluminum) interdigitated electrodes. The doping of the active layer was performed by immersing the device in hydrochloric acid solution with pH 2 during different times in order to promote different doping levels of the semiconductor polymer. Was verified that the proposed diode, which exhibits well-defined metal-semiconductor junction, operates as a Schottky diode, with good ideality factor, 10 ± 3, and low turn-on voltage, 1,2 ± 0,2 V, in comparison with conventional organic polymeric diodes. Contrasting with the ideality factor and turn-on voltage, the diode rectification ratio was obtained as 7, a value lower than the expected for a good organic diode. Was also showed that the diode characteristics were dependent on the semiconductor polymer doping level, and that the diode characteristics were optimized with doping promoted by immersion in the acid solution for times longer than 50 s. Furthermore, as was showed that the diodes properties are dependent on the semiconductor...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Sol-gel process has facilitated the processing of Organic-Inorganic Hybrid Materials with several scientific applications and technologies. The hybrid combine the advantages of the Sol-gel process with specific characteristics of organic polymers, allowing processing of thin films without fractures or fissures. The incorporation of azo dyes in polymer matrices has been widely used in the investigation of optical properties. The azo dye Disperse Red (DR1) presents optical alterations when exposed to visible or ultraviolet light. The alterations occur due to transitions of their isomers, trans and cis, caused by photoisomerization, due to electronic transitions of azo group (-N=N-), presenting photochromic and/or photorefractive effects. The hybrid system used in this work is the precursor 3- Glycidoxypropyl-Trimethoxi-silane (GPTS), the Tetraethylorthosilicate (TEOS) and DR1 as a dopant. The characterizations were performed using absorption spectroscopy UV-Vis which allowed the identification of the absorption bands and its variations when the samples were treated thermally and/or illuminated by ultraviolet light