298 resultados para Aparelho de Thurow modificado
Resumo:
This study compared the effect of the treatment protocol for correcting Class Il malocclusion using the Herbst appliance followed by full fixed Straigh-wire mechanics, in two populations, one Brazilian and one of North American origin As a untreated control sample the data from the University of Michigan Elementary and Secondary School Growth Study (UMGS) was used. Our sample was composed of 12 males and 12 females, with initial mean age of 12 years 7 months and final mean ages of 15 years and 3 months. The Michigan patients comprised 21 females and 7 males, with an initial mean age of 11 years and 9 months and final mean age of 14 years and 4 months. The control sample was paired in number, sex and age to the treated Michigan sample. ln both treated groups, lateral cephalometric radiographs were obtained before the Herbst appliance was cemented and at the end of the fixed appliance phase, The first comparison involved the Brazil group and the untreated controls, which demonstrated that the association of the Herbst appliance followed by fixed Straight-wire appliances provoked positive effects on the dentofacial complex, improving pre-existing maxillo-mandibular relationships, besides increasing dentoalveolar compensations which contributed to correct the malocclusion. The second comparison, involved the Brazl1ian and North-American patients treated with the same protocol. Although the pre-treatment comparison showed that the two groups were not similar in all aspects, they presented almost identical therapeutic modifications, which indicate that the effect of' treatment was very similar. These results point out that, in Class ll treatment, the combination of Herbst/Straight-wire mechanics produce consistent and systematic effects, correcting or minimizing possible skeletal imbalances
Resumo:
Evaluate the effects of a modifi ed ConstraintInduced Therapy intervention protocol regarding movement quality and frequency of use of the affected upper extremity on children with hemiplegic cerebral palsy. Longitudinal study of a single case, performed with a four year old submitted to intervention during three hours daily, for ten days, restricting the non-affected upper extremity for eight hours daily. Data were collected using the Pediatric Upper Extremity Motor Activity Log and analyzed using the arithmetic mean. Signifi cant improvement in quality of movement and frequency of use of the upper limb from pre to post-intervention were noted, maintaining the result in later data collection, besides the acquisition of functional motor skills. The modifi ed constraint-induced movement therapy protocol of this study was effective in treating the child with hemiplegic cerebral palsy, the results may be useful for professionals working with this clientele, assisting them in the intervention process.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilíbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades físicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada híbrida em dentina humana e bovina. A tensão superficial de quatro diferentes líquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro líquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada híbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatística de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os líquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Há uma grande expectativa para o desenvolvimento de biossensores miniaturizados, que permitam análises mais eficientes e rápidas, em matrizes complexas como as encontradas: no ar, alimentos, águas residuais e em medicamentos. Recentemente, filmes poliméricos inteligentes ativados por estímulo externo têm atraído bastante interesse no desenvolvimento desses tais nanosensores para uso em sistemas químicos e bioquímicos. Estes materiais apresentam uma alta sensibilidade a alterações físicas ou químicas ocorridas na sua interface, e respondem seletivamente a essas mudanças para se adaptarem ao meio. Juntando-se as propriedades estímulo-responsivas desses polímeros com a alta seletividade de reações biológicas tem-se uma excelente combinação para a criação de nano biossensores. A esse tipo de sistema: interfaces/material biológico adota-se a nomenclatura biointerface. As biointerfaces são biossensores em potencial, e na preparação dos biossensores a tarefa mais complicada na sua preparação é o desenvolvimento de superfícies adequadas para o interfaceamento com material biológico, de maneira que a parte biológica possa atuar de forma sensível e estável. A primeira etapa consistiu na produção e caracterização dos polímeros escova (P2VP), os quais serão preparados pelo processo de deposição térmica. A caracterização dos mesmos foi realizada por imagens microscopia de força atômica (AFM), via eletroquímica e por transmissão de ressonância plasmônica de superfície. Na etapa posterior foi estudada a imobilização da glicose oxidase para a preparação do biossensor. O dispositivo fabricado foi empregado para a determinação direta de glicose. Desta forma, esperou-se obter uma metodologia de menor custo e tempo de análise. Logo, este estudo irá contribuir de forma significativa sobre os processos de montagem de biossensores a partir de compostos nanoestruturados. Foram utilizadas técnicas de ...
Resumo:
The study and selection of an equipment of air conditioner for any type of environment, should be made without overestimate or undersizing the project. The undersizing does not provide an adequate comfort temperature if the environment is too hot because the air conditioner does not remove all the heat necessary in the environment. But if the project is oversized, energy consumption is higher and there is an unnecessary cost. To prevent these failures is necessary to make a calculation of the thermal load on the environment and choose the equipment that has a higher cooling capacity than the calculated heat load and closer to the calculated heat load. In this graduate work will be chosen an air-conditioned equipment for bus, showing the calculations made for the thermal load for various types of heat gain in this type of vehicle. The thermal load on vehicles is more complicated to calculate than in areas because there are several factors that vary with the movement of the vehicle. It will also explain the compression refrigeration cycle, which is the cooling system used in vehicles because it is weightless, compact and lower cost. From the calculated heat load, it will be chosen an air conditioner that best suits the project and, finally, a brief presentation of the selected equipment will be made
Resumo:
The study of mechanical properties of high-alloy special steels is of great interest of the steel industry due to the great demand by companies that manufacture automotive components of high criticality, and also because of its high commercial value. However, the development of this type of alloy metals demand highly technical knowledge. Among these extremely important kinds of steel, the subject which is the interest of this study is the special steel modified by niobium. The manganese and niobium are the main alloying elements in the composition of these steels, both of them increase the stability of the austenite region, however, manganese increases the hardenability and tensile yield strength, and niobium increases the mechanical strength and promotes refining the grain. The mechanical characterization of steel SAE 1312 modified the niobium was made in order to gain a better understanding of the influence on the mechanical properties caused by aging at different temperatures and for different reductions in the drawing of gauge material. This characterization was made by means of tensile test and hardness. This material showed an increase in yield strength and hardness when gauge with large reductions during the wiredrawing, but when subjected to aging temperatures higher than 300 ° C had a slight loss of these properties
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB
Resumo:
Pós-graduação em Química - IQ
Resumo:
When well indicated, the orthodontic surgical approach is the ideal treatment mean for Skeletal Class III adult patients. To improve facial esthetic results from orthognatic surgery, the leveling and alignment of maxillary dental arch must be achieved with minimal inclination and projection or even retro-inclination of anterior upper teeth. During a pre-surgical phase of 12 months, headgear bilateral force of 150 g/F was applied to the upper molars of a 22 years old male compliant patient with Class III skeletal malocclusion, to provide an upper teeth control of mesial tipping and projection during alignment and leveling. The ideal occlusal parameters required for surgical procedure were achieved without dental extractions permitting a total treatment period of 37 months. The outcomes remained stable over 3 years follow up after the removal of the appliance. The results indicate that, although headgear use depends greatly on patient compliance, when well indicated it is an interesting alternativetopromote dentaldecompensationon pre-surgical period, in order to allow surgical correction of skeletal Class III malocclusion.
Resumo:
Two treatment options are available for adult patients with skeletal Class II malocclusion caused by mandibular deficiency: combined mandibular advancement surgery and orthodontic treatment or mandibular advancement appliance. This study aimed to analyze the effects of two therapeutic modalities of Class II malocclusion treatment with mandibular deficiency. Two distinct individuals with Class II malocclusion division 1 and mandibular deficiency were treated after growth spurt. The first individual used the Herbst appliance as a therapeutic option and the second individual was treated with bilateral sagittal osteotomy. The cephalometric, occlusion and face results were evaluated for both individuals. Correction of Class II malocclusion was observed on both Herbst and surgery patients resulting on a normal occlusal relationship with normal overjet and overbite. Therefore it was concluded that Herbst appliance can be used to treat borderline skeletal Class II in adult patients.
Resumo:
The study aimed to assess the degree of dental crowding correction on the lower anterior region of patients treated with T4k functional appliance using Little’s irregularity index. Twenty caucasian patients of both gender (10 female and 10 male) were selected. They featured malocclusion Class I and II in mixed dentition, with chronological age between 5.7 and 11 years. The treatment lasted from 1 year and 11 months up to 3 years and 11 months. Lower anterior crowding was measured using Little’s irregularity index. Measurements were obtained on study models achieved before and after functional orthopedic therapy, using a digital caliper in millimeters and placed parallel to the occlusal plane. Overjet and overbite measurements were also performed using a caliper. Results demonstrated that the therapy provided significant decrease in overjet (average = 1.55 mm) and also in the irregularity index (average = 1.23 mm). There was a nonsignificant raise in overbite. There was no relation between the studied variables and the treatment period or even with the patient’s age in the beginning of the therapy. The treatment with T4k resulted on reduction and improvement of dental crowding.
Resumo:
Due to its high prevalence in general population, Angle Class II malocclusion has been widely studied by several authors, as well as the methods for its treatment. Among the possible treatment methods stands out the Herbst appliance. Reintroduced more than three decades ago in the orthodontics community, it became the most utilized appliance because it does not require patient compliance, and provides continued action through bilateral telescopic tubes. The objective of the present article was to demonstrate the early treatment of Class II Division 1 malocclusion with mandibular retrusion using Herbst appliance.