193 resultados para Aditivos para remoção de SOx
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g)
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Aquicultura - FCAV
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A remoção da smear layer é um procedimento importante para a regeneração periodontal e para o tratamento da sensibilidade dentinária. Diversos tratamentos tem sido realizados para sua remoção, porém, mostrando resultados conflitantes ou insatisfatórios. No presente estudo nos propomos a analisar através do microscópio eletrônico de varredura a eficiência dos detergentes: lauril sulfato de sódio, Plax e de mamona assim como o EDTA 24% na remoção da smear layer. Todos os produtos testados foram aplicados com bolinha de algodão, renovada a cada 30 segundos, a qual era esfregada na superfície radicular por diferentes períodos. As fotomicrografias foram analisadas através da aplicação de um índice de remoção da smear layer por três examinadores calibrados e os resultados analisados estatisticamente. De acordo com nossos resultados pudemos chegar as seguintes conclusões: 1- a instrumentação com curetas de Gracey provocou a formação da smear layer; 2- o detergente lauril sulfato de sódio não removeu a smear layer, tendo sido o pior resultado entre os detergentes testados; 3- Os detergentes Plax e de mamona mostraram resultados semelhantes entre si e superiores ao controle negativo e ao lauril sulfato de sódio, porém, não removeram a smear layer satisfatoriamente; 4- O EDTA 24% neutro mostrou ser eficiente para a remoção da smear layer.
Resumo:
It was aimed to evaluate the chemical composition of grass silage-mombasa associated with different additives in four times of opening the silo. The experiment was conducted in UFGD. After harvesting the forage, biomass in natura crushed, was taken to the lab, homogenized and enriched on the basis of natural mass, with the following additives: 5% wheat bran, 5% of waste (broken grain and soy ice cream cone) of soybean, 5% urea in natural matter and the witness (without additive). The silos were opened after (unprocessed material), 15, 30 and 45 days, for the analysis of chemical composition. The data obtained were analyzed through the statistical programme SISVAR and averages were compared to 5% of probability, by Skott-Knot. The grass silage-mombasa without additive presented major (P<0.05) dry matter content compared to other treatments at time 0 and 30 days of silage and did not differ (P>0.05) of grass silage- mombasa associated with 5 of urea in 15 days and 45 of silage. The grass silage-mombasa with 5% urea showed the highest crude protein content at time 0 and differed from other treatments. The silage of mombasa associated with 5% urea provided greater in vitro digestibility of dry matter to 15 days of silage.
Resumo:
Não disponível
Resumo:
The tanning wastes are characterized to be significant sources of pollution in the hydrosphere when non adjusted or disposed adequated form. That happens because this industry type uses the chromium to tan hides, and this element is present in discharges concentrations in final wastes, characterizing this waste type as dangerous, according to the Associação Brasileira de Normas Técnicas, através da Norma Brasileira 10.004 de 2004. Due to this, the research proposes a form to reduction chromium of the tanning wastes through the process of adsorption. For that were used mining-wastes of Corumbataí Formation clays, material commonly used in the production of ceramic products in Rio Claro (SP). They were accomplished laboratory essays that involved the preparation of different clays pulps and subsequent mixture of these with the tanning wastes, maintaining them under different mixing times and adsorption contacts. After the separation of the mixtures, the leached were chemically analyzed and it was seen the efficiency of chromium reduction and your relationship with the variation of different times of contact clays/wastes and different grain sizes used in the pulps preparation.
Resumo:
The volume of liquid effluent generated in cattle slaughterhouses is quite high and cannot be released untreated in water bodies due to its high pollution load of predominantly organic origin. To minimize the environmental impacts of its industrial wastewater and meet the local environmental legislation, abattoirs shall make the treatment of these effluents. The present work aims to develop the study of a reactor by sequential batch pilot scale, in order to optimize their performance in treating wastewater from a cattle slaughterhouse. The treatment system used was developed and installed in the Laboratory of Wastewater Treatment, in Faculty of Science and Technology UNESP, Presidente Prudente campus. The procedure used followed the operation of sequential batch reactors, in which all processes and treatment operations occurring sequentially in a single unit, by establishing specific operating cycles, which comprise the following separated phases: aerobic reaction, anoxic reaction, sedimentation and emptying. Aiming to improve the quality of treatment was planned the addition of coagulant Poly Aluminum Chloride (PAC) in the reactor, by determining their optimal dosage by Jar-test trials. Were prepared four steps with specific operating cycles: step one or acclimatization (10 hour of aeration, one hour and 30 minutes of sedimentation and 30 minutes for exchanging the effluent); step 2 (6 hours of aeration or aerobic phase, 4 hours and 45 minutes of stirring or anoxic phase and 1 hour and 15 minutes for sedimentation and exchange effluent); step 3 (2 hours and 30 minutes of aeration, 8 hours and 15 minutes of stirring and 1 hour and 15 minutes for sedimentation and exchange) and step 4 (2 hours of aeration, 8 hours and 45 minutes of stirring and 1 hour and 15 minutes for sedimentation and exchange)... (Complete abstract click electronic access below)