124 resultados para ultrasonic speed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Applications of ultrasound were starting from 1912 with the primary objective the detection of icebergs on prevention of maritime accidents. Algae, fish deaths and destruction were observed in the vicinity of sonar that equipped ships and submarines during the First World War.The evolutions of research and studies with ultrasound have big advances following the discovery of piezoelectric transducers in science and technology. As an example we can mention its application in microsurgery, fatigue detection in aerospace mechanics, catalysis sonochemical, biotechnology and others.The work presented here aims to demonstrate the application of ultrasonic in pulsed mode beams in biotechnology with the aim of improving the fermentation of a culture broth containing biological agents. In these experiments we used as ultrasound equipment and oscilator Sonics VCX-600 (20KHz), probe type wave guide. The experiments were conducted in a glass reactor of 200 mL of biomaterial containing cane juice and Saccharomyces cerevisiae in suspension. The parameters analyzed were related to the content Alcohlic (FID gas chromatography), and cell viability (Neubauer chamber), TRS (refractometry). Analysis of results showed that the total production exceeded in irradiated samples compared to normal fermentation (without ultrasound), suggesting additional advantage of ultrasound activation. Lastin Trials 1400 min, showed ethanol production systems 12% more than non-enabled systems. In this context alternatives for ethanol production, bio fuel and many other byproducts of the alcohol industries and chemicals could benefit from the use of ultrasound beams in this range of frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of ultrasonic waves during the initial setting of the glass ionomer cements (GIC) has demonstrated increase of the cure speed, reduction of air bubbles and improves in some mechanical properties. The aim of this study was to evaluate the effect of the ultrasound on the microhardness and the superficial roughness in two GICs (FUJI IX GP (GC Corporation) and Ketac Molar EasyMix (3M ESPE)). Forty specimens were confectioned, twenty for evaluation of the superficial roughness and twenty for evaluation of the microhardness. Half of them received for thirty seconds the ultrasonic waves application. The readings of the roughness had been carried before and after the toothbrushing test. The twenty remaining specimens had been polished with abrasive sandpapers of decreasing granulations and submitted to the hardness test. The results, analyzed for the variance analysis (ANOVA) (p<0,05), had demonstrated increase of the hardness for all the groups with the application of ultrasonic waves, being bigger for the Ketac Molar EasyMix. The ultrasound application also caused significant reduction of the superficial roughness for the Ketac Molar EasyMix. After the toothbrushing test, this last property increased for all the materials. It could be concluded that the application of ultrasonic waves was effective in increasing the superficial hardness of the materials and that it improved the roughness of the Ketac Molar EasyMix before the toothbrushing test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of ultrasound waves with a conventional dental ultrasonic scaler on glass ionomer cements surface accelerated initial setting reaction and improved the mechanical properties. Objective: This study evaluated the ultimate tensile strength of glass ionomer cements after ultrasonic excitation and different water storage times. Material and method: Twelve specimens of each material (Fuji IX GP, Ketac Molar Easymix and Vitremer) were prepared, and six of each received a 30-second ultrasound application during initial setting of the cements. After storage of the 24 hours or 30 days, the specimens were sectioned into stick to microtensile testing and the mean ultimate tensile strength values were submitted to Welch’s ANOVA and Tamhane’s test. Result: The results showed that the Vitremer presented the highest mean tensile strength. The chemically set Fuji IX GP presented significantly higher mean tensile strength after 30 days than after 24 hours of storage (p < 0.05). At 24 hours, the ultrasonically set Fuji IX GP presented significantly higher mean tensile strength than their counterparts set under standard conditions (p < 0.05). Conclusion: Treatment with ultrasound increased the tensile strength of Fuji IX GP in the early period of maturation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The non-eruption of teeth due to highly keratinized gingival mucosa is a frequent event in the pediatric dentistry, which harms the oral aesthetics and function. A surgical excision of the involved area is indicated, exposing the non-erupted tooth. This procedure involves anesthesia and cutting instruments that may increase the fear and anxiety in young patients. The use of new technologies has avoided these instruments and has promoted more comfort to the patients. This study presents clinical cases in which gingivectomy was performed using the innovative method with an ultrasound-activated CVD tip. It was concluded that this method presented effectiveness, promoted more comfort, and less fear to the patients, making its use a viable alternative to pediatric surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the morphology and adhesion of blood components on root surfaces instrumented with piezoelectric ultrasonic Piezon Master Surgery. Methods 10 teeth were used in this study. The teeth had their proximal divided into four areas that received different treatments: Group 1: untreated control Group 2: scaling with manual instrument; Group 3: scaling with ultrasound; Group 4: Scaling with manual instruments and ultrasound. We obtained 20 samples, 10 of which were used to analyze the morphology and the other 10 were used for analysis of adhesion of blood components. The specimens were analyzed by scanning electron microscopy. Photomicrographs were analyzed by the scores of adhesion of blood components and the index of root morphology. The results were statistically by the Kruskall-Wallis and Mann-Whitney with a significance level of 95%. Results The morphological analysis showed that the Group 1 had a surface unchanged in relation to other groups (Group 1 X Group 2 = 0.0025; Group 1 X Group 3 = 0.0003; Group 1 X Group 4 = 0.0003) and Group 2 presented a smoother surface compared to Group 1 and groups instrumented with ultrasound (Group 2 X Group 3 = 0.0025; Group 2 X Group 4 = 0.0025) there were no statistical differences between the Groups 3 and 4. analysis of adhesion of blood components showed that the Groups 2, 3 and 4 had no statistically significant differences between themselves, but more biocompatible surfaces promoted the surface untreated control (Group 1 X Group 2 = 0.02; Group 1 X Group 3 = 0.04; Group 1 X Group 4 = 0.005). Conclusion The instrumentation with piezoelectric ultrasonic promoted an irregular root surface, but did not negatively affect the adhesion of blood components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of ultrasound and osmotic dehydration pretreatments on papaya drying kinetics was investigated. The ultrasound pretreatment was carried out in an ultrasonic bath at 30 A degrees C. The osmotic pretreatment in sucrose solution was carried out in an incubator at 34 A degrees C and agitation of 80 rpm for 210 min. The drying process was conducted in a fixed bed dryer at 70 A degrees C. Experimental data were fitted successfully using the Page model for dried fresh and pretreated fruits, with coefficient of determination greater than 0.9992 and average relative error lower that 14.4 %. The diffusional model was used to describe the moisture transfer, and the effective water diffusivity was identified in the order of 10(-9) m(2) s(-1). It was found that drying rates of osmosed fruits were the lowest due to the presence of infused solutes, while the ultrasound pretreatment contributed to faster drying rates. Evaluation of the dried fruit was performed by means of total carotenoids retention. Ultrasound treatments in distilled water prior to air-drying gave rise to dried papayas with retention of carotenoids in the range 30.4-39.8 % and the ultrasonic-assisted osmotic dehydration of papayas showed carotenoids retention values up to 64.9 %, whereas the dried fruit without pretreatment showed carotenoids retention lower than 24 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)