288 resultados para stabilized zirconia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)Methods. Sixty disc-shaped specimens (0, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200N); (T) thermal cycling (6,000 cycles/5-55 degrees C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200N with temperature range from 5 C to 55 C for 60s each); (AUT) 12h in autoclave at 134 degrees C/2 bars; and (STO) storage in distilled water (37 degrees C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (alpha = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests.Results. ANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).Signcance. Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of the core substrate type (dentin and composite resin) on the retention of crowns made of yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP), submitted to three inner surface conditionings. For this purpose, 72 freshly extracted molars were embedded in acrylic resin, perpendicular to the long axis, and prepared for full crowns: 36 specimens had crown preparations in dentin; the remaining 36 teeth had the crowns removed, and crown preparations were reconstructed with composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and 72 Y-TZP copings for the tensile test were produced. Cementation was performed with a dual-cured cement containing phosphate monomers. For cementation, the crown preparation (dentin or resin) was conditioned with the adhesive system, and the ceramic was subjected to one of three surface treatments: isopropyl alcohol, tribochemical silica coating, or thin low-fusing glassy porcelain layer application plus silanization. After 24 hours, all specimens were submitted to thermocycling (6000 cycles) and placed in a special tensile testing device in a universal testing machine to determine failure loads. The failure modes of all samples were analyzed under a stereomicroscope. Two-way analysis of variance showed that the surface treatment and substrate type (alpha=0.05) affected the tensile retention results. The dentin substrate presented the highest tensile retention values, regardless of the surface treatment. When the substrate was resin, the tribochemical silica coating and low-fusing glaze application plus silanization groups showed the higher retention values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core - MAu; zirconia core - MZi) and the quality of the veneer/core interface (complete bonded - MZi; incomplete bonded - MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The test groups were experimental zirconia, Zirkonzahn zirconia, and Schuetz zirconia. Blocks of partially sintered zirconia were cut into disks (n=20) and then veneered with a feldspathic porcelain. Half of the specimens from each group (n=10) were incubated in 37°C water for 24 hours, and the other half were thermocycled. All the specimens were then subjected to shear testing. The fractured areas were analyzed with optical stereomicroscopy and classified as adhesive, cohesive, or an adhesive-cohesive failure. Spectral patterns were examined to detect bands related to the zirconia and feldspathic porcelain phases. The shear strength data were submitted to 2-way ANOVA. Results No significant differences in shear bond strength were observed among the 3 groups, regardless of whether or not the specimens were thermocycled. Adhesive failures were the most prevalent types of failure (70%). Raman spectra were clearly distinguished for all the materials, which showed the presence of tetragonal and monoclinic phases. Conclusions The controlled production of the experimental zirconia did not influence the results of the bond strength. Raman analysis suggested a process of interdiffusion by the presence of peaks associated with the zirconia and feldspathic ceramics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos). Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8); fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8). Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz) de baixa intensidade (30mW cm-2), aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (P<0,001 e alfa=0,05) entre as médias dos parâmetros de tempo para consolidação óssea observadas nos animais dos grupos tratado (média de 67,5 dias) e controle (média de 106 dias). Este protocolo de estimulação ultra-sônica promoveu sinais clínicos e radiográficos acelerados da consolidação óssea nas fraturas tratadas. Os resultados deste estudo sugerem que o ultra-som pulsado de baixa intensidade pode ser indicado como terapia adjuvante de fraturas diafisárias recentes em cães.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho foi conduzido para verificar o efeito do tamanho do corte, 2,5 x 2,5cm (corte 1) e 2,5 x 5,0cm (corte 2), e da temperatura de armazenamento (3, 6 e 9ºC), na velocidade da modificação da atmosfera ambiente e nas características químicas de mamões do grupo `Formosa' minimamente processados e embalados em copos plásticos (500ml). A concentração de CO2 no interior destes copos aumentou 2 a 3 vezes, durante as primeiras 6 horas após o corte, para depois diminuir e se estabilizar. Esta concentração aumentou com o aumento da temperatura de armazenamento. A umidade dos pedaços diminuiu consideravelmente nos dois primeiros dias, e a temperatura que melhor conservou a umidade foi a de 6ºC. A acidez total titulável foi menor no corte 2, com as maiores reduções a 6 e 9oC. Os teores de sólidos solúveis totais não variaram entre os tratamentos, e os cuidados higiênicos adotados durante o processamento permitiram a obtenção de produtos com baixa contagem microbiana, 10³UFC.g-1 nos pedaços armazenados a 9ºC após sete dias, e com boa manutenção da qualidade sensorial das mesmas. Estes resultados permitem indicar o mamão `Formosa' para a produção de produtos minimamente processados, na forma de pedaços, com conservação refrigerada (3 e 6ºC ) por um período de 7 dias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Syagrus picrophylla belongs to the Arecaceae family. Its propagation is made by seeds; however there is a lack of information in the literature about its seed germination. The objective of this work was to evaluate the effects of temperature and scarification on the germination of S. picrophylla seeds. The experiment was carried out at the State University of São Paulo, Jaboticabal Campus, Brazil. The experimental design was entirely randomized in a factorial arrangement 5 x 2 (five temperature conditions combined with or without mechanical scarification. The number of germinated seeds that showed primary root protrusion was noted daily, and when the germination was stabilized, the germination (%G) and germination rate (GR) were calculated. The analysis of variance (ANOVA) was carried out for means comparing by the Tukey test at 5% confidence level. It was concluded that the greatest %G were obtained at 20-30 degrees C (62%) and 25-35 degrees C (59%) alternated temperatures; %G and GR were similar for both scarified and non-scarified seeds, and there was a faster germination at 20-30 degrees C alternated temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Buscando-se avaliar morfofisiologicamente a rebrota do capim-mombaça, quatro desfolhas foram impostas ao perfilho principal, sendo estudado o comportamento da planta em termos da taxa de expansão da área foliar, crescimento do sistema radicular, nível de carboidratos totais não estruturais (CTNE) da raiz e do colmo, taxa de crescimento relativo (TCR), taxa de assimilação líquida (TAL) e razão de área foliar (RAF) às idades de 2, 5, 9 e 16 dias após as desfolhas, bem como da taxa fotossintética máxima às idades de 2, 6 e 13 dias das folhas remanescentes à desfolha. As desfolhas foram as seguintes: remoção de todas as lâminas foliares (desfolha total), a remoção da lâmina da folha adulta mais jovem (desfolha superior), a remoção das lâminas das duas folhas adultas mais velhas (desfolha inferior) e controle (sem desfolha), juntamente com o corte dos demais perfilhos, realizado a 8 cm do solo. Foram observadas cinco repetições por tratamento, segundo o delineamento inteiramente casualizado. As folhas adultas não diferiram quanto às taxas fotossintéticas máximas, que exibiram aumento nos primeiros dias após a desfolha, e queda aos 13 dias. A desfolha reduziu os teores de CTNE da base do colmo, principalmente nas plantas sob desfolha total. Comprometimento do crescimento do sistema radicular e do teor de CTNE das raízes foi observado nas plantas sob desfolha total, que também tiveram sua TCR reduzida nos primeiros dias de rebrotação. Entretanto, o aumento na RAF possibilitou a estas plantas recuperação da TCR e alta taxa de expansão da área foliar, igualando a área foliar das demais plantas aos 16 dias de rebrota.