126 resultados para sonic boom


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Each year, there is an increase in pesticide consumption and in its importance of use in the large-scale agricultural production, being fundamental the knowledge of application technology to the activity success. The objective of the present study was to evaluate the influence of working pressure on the drift generated by different spray nozzles, assessed in wind tunnel. The treatments were composed of two spray nozzles AXI 110015 and AXI 11002 with pressure levels of 276 and 414 kPa. The spray solution was composed by water and NaCl at 10%. The applications were conducted at wind speed of 2.0 m s-1, being the drift collected at 5.0; 10.0 and 15.0 m away from the spray boom and at heights of 0.2; 0.4; 0.6; 0.8 e 1.0 m from the tunnel floor. To both spray nozzles, the greatest drift was collected at the smallest distance to the spray-boom and at the lowest height. The AXI 11002 nozzle gave a smaller drift relative to the AXI 110015 nozzle for the two tested pressures and for all the collection points. Regardless of the nozzle, a rise in the working pressure increases the spray drift percentage at all distances in the wind tunnel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the research was to evaluate the effect of adjuvants on the spray drift applications from mixture of 2,4-D + glyphosate. The trial was carried out in field conditions in a completely randomized design. The treatments corresponded to solutions containing mixture of the herbicides 2,4-D + glyphosate (670 and 1068g ha-1, respectively) adding the adjuvants (v v-1): mineral oil (0.5%); anti-drift agent (0.09%); spreader-sticker A (0.1%); liquid fertilizer (0.05%); spreader-sticker B (0.25%); and only herbicides without adjuvantes (control). Nylon strings were used to drift determination outside the application area (1, 5, 10, 20, 50, 100 and 200 m away) with 4 replications and six foam cylinders placed on the boom of the sprayer were used to collect the droplets subject to drift. The applications were performed simultaneously, using a specific salt tracer for each spray solution to quantify the deposits by spectrophotometer. It was not possible to verify effect of the adjuvants on drift at different distances of the application area. Based on droplets collected above the boom spray, it was found that susceptibility to drift was lower with the mineral oil and the anti-drift agent. The drift risk was higher with the liquid fertilizer and the spreader-sticker B.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciências Sociais - FFC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Relações Internacionais (UNESP - UNICAMP - PUC-SP) - FFC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed to evaluate the volumetric distribution profiles, droplet spectra, surface tension, contact angle of droplet and the spraying liquid deposition over the peanut leaves (Arachis hypogaea L.), under artificial rain, in comparison with deposition without rain, using two hydraulic nozzle models of plain fan and insecticide spraying liquids with and without adjuvants addition. It were used a patternator for volumetric distribution analysis, a laser particles analyzer to evaluate droplet spectra produced by SF 110015 and XR 110015 nozzles and tensiometer for droplet tension and contact angle. The spraying liquids evaluated were: water, lambda-cialotrina, lambda-cialotrina + nitrogen fertilizer and lambda-cialotrina + mineral oil. All experiments followed a completely randomized design. Data were submitted to variance analysis by F test and the means comparisons by Scott-Knott test at 5% of probability. According to the results, it must be considered the maximum spacing in spray boom usage of 50 and 90 cm between the nozzles SF110015 and XR110015, respectively. The adjuvants effects on droplet spectra have shown addicted to the nozzle and the product used, and the adjuvants addition to the spraying liquid affected the potential risk of drift; The Volumetric Median Diameter (VMD) of produced droplets by nozzles filled into thin class and were not influenced by the adjuvants. The nitrogen fertilizer adjuvant may be indicated to promote improvements on coverage and droplet deposition on target.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Economic crises caused by speculative bubbles are recurring in economic history but there is still no consensus on how it begins, grows and overflows. Economists and regulators seem to be inefficient in predicting and preventing this process, which is so detrimental to economic functioning. This failure proved to be obvious with the American subprime crises, which had great impact on various sectors of the U.S. economy. In this paper, we perform a literature review of the traditional theory of finance, mainly represented by the Efficient Market Hypothesis. According to this theory, asset prices always reflect their intrinsic value, assumption that doesn’t match the price boom followed by a crash, observed in the crisis generated by speculative bubbles. Finally, we present a new way to analyze this phenomenon, in the light of the investors’ behavioral aspects and the flaws inherent to the financial markets

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study area is the Garoupa Field, located 75 km from the coast of Rio de Janeiro in bathymetric elevation of 125 m and it is the first important offshore discovery of the Campos Basin with hydrocarbon production in the Albian carbonates. The high significance of carbonate rock reservoirs for the global oil industry and its degree of complexity, combined with the fact that the Garoupa Field is a mature field, make this research project interesting to develop a re-exploratory vision of the study area. The objective of this paper is to characterize the physical properties of the Macae Group reservoirs in the Garoupa Field through well correlation techniques, petrophysical analysis and seismic interpretation (3D), in order to evaluate qualitatively and quantitatively the response of geophysical data to the presence of carbonate rock reservoirs. From the analysis of well profiles (gamma ray, resistivity, density and sonic) it was possible to identify six reservoir levels in the Quissamã Formation. As a result, the reservoirs have good correlation between the wells in the Garoupa Field and show lateral facies variation. In the seismic interpretation, structural contour maps were generated in time (ms) from the top of the Macae Group and two horizons that correspond to the reservoir levels. These maps show that the oil producing area of this field is a structural high located at the west of the interpreted seismic cube, and it was classified as a rollover limited by lateral faults forming a horst. The seismic attribute maps show a good response to the reservoirs of the Garoupa Field because they are associated with amplitude anomalies, verified by the correlation between the physical properties of the reservoir rock and seismic data through cross plots, with emphasis in a linear correlation between the resistivity profile and the values of Maximum Absolute Amplitude and RMS Amplitude attributes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work consists of analyzing the risk management of investments by applying statistical concepts, economic and mathematical models considering the assets on the market on renowned financial institution. The assessment of these risks becomes increasingly interesting in view of minimizing your losses thus maximizing your chances of gains in both markets boom as extreme uncertainty, even with the sudden changes of scenery. Introducing concepts of investment funds, as well as the classification of the types of funds as funds management and equity, its guidelines, the concept of market investment funds. The types of assets comprising the investment funds, their taxation rules beyond the incidents that market widely used by investors and skilled people, both physical and legal, who keep their resources in this modality. With the historical data collected yields of investment funds of the Bank of Brazil, is an accomplished inflation adjustment and calculated the mean and variance for the verification of the model of Markowitz efficient frontier, a method used as investment analysis. This scan is used Matlab to obtain the set (or border) efficient portfolios. Once verified such data, there will be a critique of the Markowitz model as a quadratic programming and more coherent risk measures currently studied as VaR and CVaR minimizing the expected error, approaching our studies of current research. It is found that such studies have much to be explored, since there are many discussions about how effectively measure risk investments such as its characteristic and behavior, using a time series and volatility

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveTo compare peri-implant tissue healing at implants installed in sites prepared with conventional drills or a sonic device.Material and methodsIn six Beagle dogs, the mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness muco-periosteal flaps were elevated and recipient sites were prepared in both sides of the mandible. In the right side (control), the osteotomies were prepared using conventional drills, while, at the left side (test), a sonic device (Sonosurgery((R))) was used. Two implants were installed in each side of the mandible. After 8weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation.ResultsThe time consumed for the osteotomies at the test was more than double compared to the conventional control sites. No statistically significant differences were found for any of the histological variables evaluated for hard and soft tissue dimensions. Although not statistically significant, slightly higher mineralized bone-to-implant contact was found at the test (65.4%) compared to the control (58.1) sites.ConclusionsSimilar healing characteristics in osseointegration and marginal hard tissue remodeling resulted at implants installed into osteotomies prepared with conventional drills or with the sonic instrument (Sonosurgery((R))).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of ultrasonic vibration on the tensile strength required to remove intraradicular post cemented with different materials. Bovine teeth were selected, and 7 mm of the cervical root canals were prepared to size 5 Largo drill, the posts were cemented with zinc phosphate, Enforce (resin) or Rely X (glass ionomer). The specimens were divided into six groups (n = 10), according to the following procedures: GI-cementation with zinc phosphate associated with traction force; GII-cementation with zinc phosphate associated with ultrasonic activation and traction force; G111-cementation with Enforce associated with traction force; GIV-cementation with Enforce associated with ultrasonic activation and traction force; GV-cementation with Rely X associated with traction force; and GVI-cementation with Rely X associated with ultrasonic activation and traction force. The tensile test was conducted using the electromechanical testing machine, the force was determined by a specialized computer program and ultrasonic activation using the Jet Sonic Four Plus (Gnatus) device in 10P. Concerning to average ranking, GI showed statistically significant difference in comparison with GII and GVI (p < 0.05); there was no statistical difference in GIII and GIV when compared to other groups (p > 0.05). The ultrasound favored the intraradicular post traction regardless of the employed cement in greater or lesser extent. The post removal is a routine practice in the dental office, therefore, new solutions and better alternatives are need to the practitioner. We did not find in the literature many articles referring to this practice. Thus, the results from this study are relevant in the case planning and to promote more treatment options.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .