155 resultados para removable
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Adhesion and colonization of the oral cavity by Candida albicans is an initial step in candidosis. Orthodontic and other oral appliances seem to favor candidal presence. The aim of this work was to compare the presence of Candida species in saliva, their adherence to oral epithelial cells, and the levels of anti-C. albicans IgA in children with or without orthodontic appliances. This study included 30 children 5 to 12 years old (9.1 ± 1.7 years old) who were users of removable orthodontic devices for at least 6 months and 30 control children of similar ages (7.7 ± 1.5 years old). The presence of yeast species in the saliva was evaluated by microbiological methods. Candida species were identified using phenotypic methods. Anti-C. albicans IgA levels in saliva were analyzed by ELISA. The yeasts adhering to oral epithelial cells were assessed by exfoliative cytology. No statistically significant differences were observed for saliva yeast counts and anti-C. albicans IgA levels between the studied groups. Children with orthodontic devices exhibited more yeast cells adhering to oral epithelial cells and a higher percentage of non-albicans species relative to the control group. In conclusion, orthodontic appliances may favor the adherence of Candida to epithelial cells but do not influence the presence of these yeasts in saliva, and the levels of anti-C. albicans IgA do not correlate with yeast adherence or presence of Candida in the oral cavity
Resumo:
Pós-graduação em Aquicultura - FCAV
Resumo:
The effect of different beverages on acrylic resin denture teeth color degradation is evaluated. Ten acrylic resin denture teeth brands were evaluated: Art Plus (AP), Biolux (BX), Biotone IPN (BI), Magister (MG), Mondial 6 (MD), Premium 6 (PR), SR Vivodent PE (SR), Trilux (TR), Trubyte Biotone (TB), and Vipi Dent Plus (VP). Teeth were immersed in staining solutions (coffee, cola, and orange juice) or artificial saliva (control) (n = 6) for 1, 7, 15, or 30 days. Specimen colors were evaluated spectrophotometrically based on the Commission Internationale d'Eclairage L*a*b* system. Color differences (Delta E) were calculated between the baseline and post-staining results. Data were evaluated by analysis of variance and Tukey test (alpha = 0.05). BI (1.82 +/- 0.95) and TR (1.78 +/- 0.72) teeth exhibited the greatest Delta E values, while BX (0.88 +/- 0.43) and MD (1.09 +/- 0.44) teeth were the lowest, regardless of solution and measurement period, and were different from BI and TR teeth (P < 0.05). Cola and coffee promoted higher denture teeth color alterations than orange juice and saliva (P < 0.05). Saliva generated the lowest denture teeth color alterations. Greater immersion times caused higher denture teeth color changes. The lifespan of removable dentures and the aesthetic satisfaction of several edentulous patients may be increased with the use of stain-resistant artificial denture teeth. (C) The Authors.
Resumo:
Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.
Resumo:
A presença de doenças sistêmicas, uso de medicamentos, e uso de próteses removíveis, entre outros fatores, podem alterar o equilíbrio fisiológico da cavidade bucal favorecendo o estabelecimento de diversas alterações e/ou patologias bucais. Assim, o estudo das prevalências destes fatores, nos pacientes odontológicos, tornam-se importantes pois devem ser considerados para elaborar o diagnóstico e definir a conduta terapêutica. Com o objetivo de delinear um perfil, avaliamos os prontuários de 500 usuários de próteses removíveis atendidos no Serviço de Medicina Bucal da Faculdade de Odontologia de Araraquara - UNESP. Analisamos os dados referentes a: características da população e das próteses removíveis, prevalência das doenças sistêmicas, uso de medicamentos e diagnóstico final das patologias ou alterações bucais. Os resultados obtidos nos permitem concluir que a maioria (74%) dos usuários de próteses removíveis eram mulheres brancas; metade da população pertencia a faixa etária de 41 a 60 anos e, quase a metade (49,2%) usava a combinação de prótese total superior e inferior. As doenças sistêmicas foram relatadas por 57,2% da amostra e a prevalência maior foi de doenças do sistema cardiovascular (25,4%). A maioria (60,4%) da população relatou uso de medicamentos e, dentre os mais freqüentes, a prevalência maior foram dos cardiovasculares (26,4%). A prevalência de patologias ou alterações bucais foi de 99,6%, sendo as relacionadas ao uso de próteses removíveis as mais freqüentes. Dentre estas, a candidose crônica atrófica ocorreu em 81,8% da população estudada e a hiperplasia fibrosa em 29,2%.
Resumo:
Statement of problem. Removable partial dentures are affected by fatigue because of the cyclic mechanism of the masticatory system ansi frequent insertion and removal. Titanium and its alloys have been used in the manufacture of denture frameworks; however, preventive agents with fluorides are thought to attack titanium alloy surfaces.Purpose. This study evaluated, compared, analyzed the corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different storage environments.Material and methods. For each metal, 33 dumbbell rods, 2.3 mm in diameter at the central segment, were cast in the Rematitan system. Corrosion-fatigue strength test was carried out through a universal testing machine with a load 30% lon er than the 0.2% offset yield strength and a combined influence of different: environments: in air at room temperature, with synthetic saliva, and with fluoride synthetic saliva. After failure, the number of cycles were recorded, and fracture surfaces were examined with on SEM.Results. ANOVA and Tukey's multiple comparison rest indicated that Ti-6Al-4V alloy achieved 21,269 cycles (SD = 8,355) against 19,157 cycles (SD = 3,624) for the commercially purr Ti. There were no significant differences between either metal in the corrosion-fatigue life for dry specimens, but when the solutions were present, the fatigue life was significantly reduced, probably because of the product-ion of corrosion pits caused by superficial reactions.