222 resultados para rectangular aquarium


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Practical methods for land grading design of a plane surface for rectangular and irregularly shaped fields based on a least squares analysis are presented. The least squares procedure leads to a system of three linear equations with three unknowns for determination of the best-fit plane. The equations can be solved by determinants (Cramer's rule) using a procedure capable of solution by many programmable calculators. The detailed computational process for determining the equation of the plane and a simple method to find the centroid location of an irregular field are also given. An illustrative example and design instructions are included to demonstrate the application of the design procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being the surface roughness a fundamental property in the fit of the castings, it was determined the roughness of 5 high-copper casting alloys, according to the heating over their melting temperature. That way, the specimens made with smooth plastic in the shape of a rectangular plate, 2 mm x 7 mm x 11 mm were invested into a cristobalite investment. After heating and elimination on the plastic, the molds were filled by 3 g of molten alloy, casted in a electrical casting machine at the casting temperature at 25 degrees C and 50 degrees C overheating. The surface roughness was measured in a roughness analyser, Talysurf. As a result, it was verified that there is a variation of surface roughness among the alloys tested, and the heating of the alloys until 50 degrees C over the melting temperature does not interfere in the roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims at studying the influence of photoperiod on the cultivation of Brycon orbignyanus (Valenciennes, 1849) (Osteichthyes, Characidae) post-larvae submitted to four treatments: 0L-24D (L=Light; D=Dark), 10 - L14D, 14L - 10D and 24L-0D, with 3 repetitions. Post-larvae measuring 7.8±0.7mm and weighting 3.5±0.8mg were distributed in 12 aquariums (10L), stocked with 12 post-larvae per aquarium. Fishes were fed daily with Artemia sp. nanplii, in 10 days experiment. A positive relationship between the survival rate (88.9±9.7%) observed in the treatment with 24 hours of luminosity, and the lowest (58.3±8.3%), in the treatment with 24 hours of darkness. No difference was showed (P>0.05) in the mean length and weight of the post-larvae, although there was greater heterogeneity among the post-larvae cultivated at the longer darkness period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This experiment was conducted to evaluate different levels of digestible energy on the performance of Nile tilapia larvae (Oreochromis niloticus) during the sexual reversion phase. Three hundred and seventy-five larvae with initial average length and weight of 21.0±4.0 mg and 1.19±0.72 cm, respectively, were allotted to 25 30L-aquarium. A completely randomized design with five treatments and five replicates was used. The aquarium with 15 larvae was the experimental unit. The diets were formulated to contain levels of 3,300, 3,525, 3,750, 3,975, and 4,200 kcal/kg of digestible energy and to be isoprotein (38.6% digestible protein). The animals were fed ad libitum five times a day. At the end of the experiment, the averages of weight (PF), survival rate (SO), condition factor (FC) and length (CF) were analyzed. Linear reduction of fishes PF and CF, as the dietary digestible energy levels increased, was observed. No differences on fish SO and FC of different treatments were observed. Deleterious effects on performance due to the increasing dietary digestible energy levels were noticed for Nile tilapia larvae during the sexual reversion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of luminosity and of the use of refuges on the initial development of Steindachneridion sp. Garavello (Siluriforme: Pimelodidae) larvae was evaluated. A thousand larvae 18.02 mm high and 62.2 mg weight were used in an entirely randomized design, with five treatments and four replicates, in 35 L-aquarium during 22 days. The treatments consisted on the following environments: darkness without refuges, clear with artificial refuge, darkness with artificial refuge, clear with natural refuge and clear without refuge. All larvae received the same feeding during the experiment. The best survival rates were found for darkness without refuges, clear with artificial refuge and clear without refuge, with 84, 76 and 70%, respectively. The best development was in darkness and without refuges. The treatment darkness with artificial refuge provided significant differences in relation to the other treatments as far as survival and weight are concerned, showing high heterogeneity for weight. Environment without refuges are the most appropriate for the larval development of this specie.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Conularia beds of the Ponta Grossa Formation (Devonian) of the Paraná Basin, southern Brazil, yield well-preserved specimens of Conularia quichua Ulrich and Paraconularia africana Sharpe. Many of these are preserved in life orientation. Also, one of the C. quichua specimens has five faces instead of four, providing additional evidence of a cnidarian affinity for conulariids. Conulariids occur in the Jaguariaíva Member (or Sequence B, transgressive system tract) containing several obrution deposits beneath marine flooding surfaces. Taphonomic data obtained from these beds show conclusively that both C. quichua and P. africana were epibenthic, sessile invertebrates originally oriented with their long axis perpendicular to the bottom and with their aperture opening upward. Of the 136 C. quichua specimens examined here, 125 occur isolated. Eleven of the C. quichua specimens collectively occur in five discrete clusters consisting of two or three specimens. All of the clustered specimens are fully inflated (exhibiting a rectangular transverse cross section) or slightly compressed longitudinally. In all of these specimens the apex is missing, and thus the problem of whether the clusters were clonal colonies or formed through preferential larval settlement cannot be resolved conclusively. However, in the single cluster consisting of three specimens, the specimens are oriented perpendicular to bedding, and thus they do not converge adapically. The three specimens are in contact with each other along the upper portion of their median region. These and the lack of any evidence of a sheet of budding stolons, suggest that this cluster was formed by preferential larval settlement. © Asociación Paleontológica Argentina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ventilatory frequency (VF) was investigated in the fish Nile tilapia, Oreochromis niloticus, subjected to confinement, electroshock or social stressor. Fish were allowed to acclimatize to tank conditions for 10 days (1 fish/aquarium). VF baseline was determined 5 days after adjustment had been started. At the 10th day of isolation, stressor effects on VF were assessed. The stressors were imposed during 60 min: pairing with a larger resident animal (social stressor), or gentle electroshock (AC, 20 V, 15 mA, 100 Hz for 1 min every 4 min), or space restriction (confinement). VF was quantified immediately after the end of the stressor imposition. Baseline of VF was not statistically different among groups. Social stressor clearly induced VF to increase, while an increased or decreased VF can be observed for both confinement and electroshock. However, fish tend to increase their VF in response to confinement and decrease in the case of electroshock. These results suggest that VF is a sensitive behavioural indicator for distinguishing stress responses in the fish Nile tilapia among different stressors. © 2006 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of disinfection treatments with chemical solutions (2% glutaraldehyde, 5% sodium hypochlorite, and 5% chlorhexidine) and microwave energy on the hardness of four long-term soft denture liners. Materials and Methods: Forty rectangular specimens of four soft lining materials (Molloplast-B, Ufi Gel P, Eversoft, and Mucopren soft) were made for each material. Ten samples of each material were immersed in different disinfectant solutions for 10 minutes or placed in a microwave oven for 3 minutes at 500 W. The hardness values were obtained with a Shore A durometer, before the first disinfection cycle (control), and also after two cycles of disinfection. Data were submitted to analysis of variance and Tukey's test (p < 0.01). Results: The highest value of hardness was obtained for Molloplast-B, independent of the disinfection technique. Mucopren soft demonstrated intermediate values and Ufi Gel P and Eversoft the lowest values of Shore A hardness. For Molloplast-B, the disinfection using glutaraldehyde demonstrated the highest value of hardness. The number of disinfections had no effect on the hardness values for all the materials studied and disinfection techniques. Conclusions: The application of two disinfection cycles did not change the Shore A hardness values for all the materials. The glutaraldehyde solution demonstrated the highest values of Shore A hardness for the Molloplast-B, Mucopren soft, and Ufi Gel P materials, while Eversoft did not present any differences in hardness when submitted to different disinfection treatments. Copyright © 2007 by The American College of Prosthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Haematological investigation is an important part of disease diagnosis. The techniques used for mammals are generally applicable for fishes with slight modification. The presence of nucleated erythrocytes and thrombocytes in fish may cause some confusion in the identification of blood cells, mainly in total leukocytes count. This work evaluated two different methods (direct and indirect) of leukocytes counting. Specimens of tilapia were divided randomly into four groups of 48 fish each. Each group was further randomized into three replicate experiments of 16 fish per replicate in 40 L aquarium and maintained for 10 days. Counting of leukocytes in peripheral blood was determined in six fishes per group at the times: 0, 3, 7 and 10 days. The direct method in Neubauer chamber showed a large dispersion of data in regard to the average, the opposite was observed in indirect method determined in blood smears that showed more homogeneity among groups. Due to this factor the indirect method can be considered more accurate than the direct method for counting leukocytes in fishes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The knowledge of dental occlusion should be considered the basic foundation to an excellent orthodontic practice. The patient's diagnose without the centric relation assessment can take the orthodontist to an unpleasant surprises. The use of rectangular archwires requires occlusal contacts been checked to decide what kind of the dental movement will be necessary to achieve the dental equilibrium and mainly to investigate if the movement will be possible. Considering the occlusal surfaces complexity, the occlusal adjustment by selective grinding should be performed during the orthodontic treatment to allow vertical dental movements reducing treatment's time. Occlusal interferences are responsible not only for biomechanics adverse effects, producing undesirable dental movements, but also for potential side effects such as excessive forces (occlusal trauma), leading to roots reabsorption. The occlusal adjustment is a determinant point on dental balance after the end of orthodontics treatments, where each posterior occlusal tooth contacts A and B, or B and C on buccolingual aspect, as well as the stoppers and equalizers contacts on mesiodistal direction must be achieved and well established. The appropriate role of anterior teeth in mandibular movements must be determined, allowing immediate disclusion of posterior teeth, known as anterior guide, and promoting protecting muscle forces to the stomatognathic system. Selective grinding should not be used. in place of well planned and executed orthodontic movement. Aim: The aim of this article is to present the rationale use of occlusal adjustment in Orthodontics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The activities and management operations of wood harvesting do not have good computational tools available to help the forest technicians with the task of cost reduction. In many cases, machines of high investment are used in wood harvesting without adequate operation planning; consequently, the cost per hour of these machines, which is high, could be reduced. Using technological resources such as the Geographic Information Systems (GIS) integrated with the Global Positioning System (GPS), which are the basis of precision harvesting. In this research, a technological tool capable of calculating and optimizing the average skidding distance of the forwarder was developed. It was used in stands of different sizes and formats through mathematical techniques and available functionalities in the Geographic Information System GRASS. The developed tool, called optimized model, divides the stand in small parts in relation to shorter skidding distances. The main variable considered was the alignment of plantation. The model was tested in eucalypt stands located in the State of São Paulo. Sixteen stands were randomly selected: eight with a rectangular polygon form, and eight with irregular polygon form. The main variables were collected in these stands. Results showed that the optimized model developed, is efficient and flexible. It was possible to divide the stands in small parts resulting in smaller skidding medium distances. The stands with irregular form had shorter skidding medium distances than the rectangular stands.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of denture base polymer type (heat- and microwave-polymerized), ridge lap surface treatment (with and without methyl methacrylate-MMA etching) and thermocycling on the microtensile bond strength (mTBS) of Biotone acrylic teeth. Flat-ground, ridge-lap surface of posterior artifcial teeth were bonded to cylinders of each denture base resin, resulting in the following groups (n=6): G1a - Clássico/with MMA etching; G1b - Clássico/without MMA etching; G2a - OndaCryl/with MMA etching; G2b - OndaCryl/without MMA etching. Rectangular bar specimens with a cross-sectional area of 1 mm 2 were prepared. Half of the bars in each group were thermocycled (5,000 cycles between 4°C and 60°C). mTBS testing was performed in an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by three-way ANOVA (a=0.05). There was no statisti-caly signifcant difference (p>0.05) for the factors (resin, surface treatment,and thermocycling) or their interactions. The mean mTBS values (MPa) and standard deviations were as follows: Thermocycling - G1a: 41.00 (14.00); G1b: 31.00 (17.00); G2a: 50.00 (27.00); G2b: 40.00 (18.00); No thermocycling - G1a: 37.00 (14.00); G1b: 43.00 (25.00); G2a: 43.00 (14.00); G2b: 40.00 (27.00). The mTBS of Biotone artifcial teeth to the denture base acrylic resins was not infuenced by the polymer type, surface treatment or thermocycling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Significant efforts are devoted to developing new ferroelectrets with well-controlled void distributions or uniform voids and with good long-term and thermal stability of the piezoelectricity. Here, we describe the concept, the fabrication, and the most relevant properties of fluoropolymer ferroelectret systems with three separate films of fluoroethylenepropylene (FEP), alternating with two polytetrafluoroethylene (PTFE) templates. The FEP films are selectively fused by means of a lamination process. Two practically identical PTFE templates are used, which have parallel rectangular openings (1.5×30 mm 2) separated by PTFE ridges of 1.5 mm width. After removing the PTFE templates, a three-layer FEP-film sandwich with tubular channels is obtained. We demonstrate that such FEP-film systems exhibit significant and stable piezoelectricity after charging under a high DC voltage. The resulting piezoelectric effect may be further improved by carefully assembling and arranging the PTFE templates during preparation. ©2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The class of piezoelectric actuators considered in this paper consists of a multi-flexible structure actuated by two or more piezoceramic devices that must generate different output displacements and forces at different specified points of the domain and in different directions. The devices were modeled by finite element using the software ANSYS and the topology optimization method. The following XY actuators were build to achieve maximum displacement in the X and Y directions with a minimum crosstalk between them. The actuator prototypes are composed of an aluminum structure, manufactured by using a wire Electrical Discharge Machining, which are bonded to rectangular PZT5A piezoceramic blocks by using epoxy resin. Multi-actuator piezoelectric device displacements can be measured by using optical interferometry, since it allows dynamic measurements in the kHz range, which is of the order of the first resonance frequency of these piezomechanisms. A Michelson-type interferometer, with a He-Ne laser source, is used to measure the displacement amplitudes in nanometric range. A new optical phase demodulation technique is applied, based on the properties of the triangular waveform drive voltage applied to the XY piezoelectric nanopositioner. This is a low-phase-modulation-depth-like technique that allows the rapid interferometer auto-calibration. The measurements were performed at 100 Hz frequency, and revealed that the device is linear voltage range utilized in this work. The ratio between the generated and coupled output displacements and the drive voltages is equal to 10.97 nm/V and 1.76 nm/V, respectively, which corresponds to a 16% coupling rate. © 2010 IEEE.