282 resultados para outdoor air flow rate
Resumo:
In this paper a non-isothermal two-phase model for oil-R134a refrigerant mixture flow is presented to predict the R134a leakage through the radial clearance of rolling piston compressors. The flow is divided in a liquid single-phase region and in a two-phase region, in which the homogeneous model is used to simulate the flow. The refrigerant leakage is determined using the mixture mass flow rate and the refrigerant mass fraction variation along the flow. The results are obtained for inlet pressures varying from 200 to 700 kPa, inlet temperatures ranging from 40 to 60 degrees C, and minimal clearances between 10 and 60 mu m. The results are firstly compared to existing isothermal model data, showing that there is a significant difference between the leakage flow rates predicted by isothermal and non-isothermal models. Finally, a useful general equation for compressor designers is proposed to calculate the refrigerant leakage for a large range of operation conditions. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
JUSTIFICATIVA E OBJETIVOS: A plasmaféresis é a técnica de tratamento de escolha para pacientes com anemia hemolítica grave. Uma de suas conseqüências é a depleção de colinesterase plasmática, o que interfere na metabolização de alguns bloqueadores neuromusculares de uso corrente na prática anestesiológica. RELATO do CASO: Paciente com 26 anos, estado físico ASA IV, gestação de 30 semanas e 3 dias, portadora de anemia falciforme, traço talassêmico e alo-imunização para antígenos de alta freqüência. Apresentou crise de falcização, sendo transfundida com derivado sangüíneo incompatível. Evoluiu com hemólise maciça, sendo admitida com hemoglobina de 3 g/dL e hematócrito de 10%, icterícia intensa, taquicardia, apatia e descoramento. Na avaliação hematológica concluiu-se ser situação de inexistência de sangue compatível para transfusão. Foi tratada com corticoterapia, imunoglobulinas e plasmaféresis. No segundo dia de internação, evoluiu com insuficiência renal aguda e edema pulmonar agudo, piora do estado geral e instabilidade hemodinâmica. Indicada a resolução da gestação em decorrência do quadro clínico da paciente e do sofrimento fetal agudo que se sobrepôs. A paciente foi admitida na sala de operações consciente, dispnéica, pálida, ictérica, SpO2 de 91% em ar ambiente, freqüência cardíaca de 110 bpm e pressão arterial de 110 x 70 mmHg, em uso de dopamina (1 µg.kg-1.min-1) e dobutamina (10 µg.kg-1.min-1). Optou-se por anestesia geral balanceada, com alfentanil (2,5 mg), etomidato (14 mg) e atracúrio (35 mg) e isoflurano. Não se observou intercorrências anestésico-cirúrgicas. Ao final, a paciente foi encaminhada à UTI, sob intubação orotraqueal, e em uso de drogas vasoativas, tendo sido extubada após 3 horas. CONCLUSÕES: Este caso mostrou-se um desafio para a equipe, visto que a paciente apresentava instabilidade hemodinâmica e alteração do coagulograma, condições que contra-indicam a anestesia regional; além disto, a plasmaféresis potencialmente depleta os estoques de colinesterases plasmáticas, o que interfere na anestesia. Entretanto, o arsenal medicamentoso disponível permitiu o manuseio seguro desta situação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This in situ/ex vivo study evaluated whether saliva stimulated by chewing gum could prevent or reduce the wear and the percent change in microhardness (%SMH) of bovine and human enamel submitted to erosion followed by brushing abrasion immediately or after 1 h. During 2 experimental 7-day crossover phases, 9 previously selected volunteers wore intraoral palatal devices, with 12 enamel specimens (6 human and 6 bovine). In the first phase, the volunteers immersed the device for 5 min in 150 ml of cola drink, 4 times per day (at 8, 12, 16 and 20 h). Immediately after the immersions, no treatment was performed in 4 specimens, 4 other specimens were immediately brushed (0 min) using a fluoride dentifrice, and the device was replaced into the mouth. After 60 min, the remaining 4 specimens were brushed. In the second phase, the procedures were repeated, but after the immersions, the volunteers stimulated the salivary flow rate by chewing a sugar-free gum for 30 min. Changes in wear and %SMH were measured. ANOVA and Tukey's test showed statistical differences (p < 0.05) for the following comparisons. The chewing gum promoted less wear and %SMH. A decreasing %SMH and an increasing enamel wear were observed in the following conditions: erosion only, 60 min and 0 min. The human enamel presented greater %SMH and less wear compared to bovine enamel. The data suggest that the salivary stimulation after an erosive or erosive/abrasive attack can reduce the dental wear and the %SMH.
Resumo:
O objetivo deste trabalho foi analisar quantitativamente os microrganismos, Streptococcus do grupo mutans e Candida sp, da cavidade bucal de pacientes com carcinoma de orofaringe antes, durante e após o tratamento com radioterapia e correlacionar fatores salivares como pH, capacidade tampão (CT) e fluxo salivar (FS). Amostras de saliva foram coletadas, diluídas e inoculadas em ágar SB-20 e ágar Sabouraud, respectivamente para Streptococcus do grupo mutans e Candida sp. Previamente à diluição, a saliva concentrada foi analisada, determinando-se os fatores salivares. Após crescimento das colônias, o número de microrganismos foi determinado em UFC/ml. A análise dos resultados permitiu concluir que houve correlação positiva entre os fatores salivares e a presença de microrganismos ilustrada pelo aumento no número de UFC/ml dos microrganismos analisados concomitantemente com a diminuição do fluxo salivar. Os efeitos da radiação comprometeram a homeostasia salivar e favoreceram o aumento das infecções por leveduras e bactérias durante o tratamento radioterápico.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Two high-performance liquid chromatographic methods for determination of residual monomer in dental acrylic resins are described. Monomers were detected by their UV absorbance at 230 nm, on a Nucleosil((R)) C-18 (5 mu m particle size, 100 angstrom pore size, 15 x 0.46 cm i.d.) column. The separation was performed using acetonitrile-water (55:45 v/v) containing 0.01% triethylamine (TEA) for methyl methacrylate and butyl methacrylate, and acetonitrile-water (60:40 v/v) containing 0.01% TEA for isobutyl methacrylate and 1,6-hexanediol dimethacrylate as mobile phases, at a flow rate of 0.8 mL/min. Good linear relationships were obtained in the concentration range 5.0-80.0 mu g/mL for methyl methacrylate, 10.0-160.0 mu g/mL for butyl methacrylate, 50.0-500.0 mu g/mL for isobutyl methacrylate and 2.5-180.0 mu g/mL for 1,6-hexanediol dimethacrylate. Adequate assay for intra- and inter-day precision and accuracy was observed during the validation process. An extraction procedure to remove residual monomer from the acrylic resins was also established. Residual monomer was obtained from broken specimens of acrylic disks using methanol as extraction solvent for 2 h in an ice-bath. The developed methods and the extraction procedure were applied to dental acrylic resins, tested with or without post-polymerization treatments, and proved to be accurate and precise for the determination of residual monomer content of the materials evaluated. Copyright (c) 2005 John Wiley & Sons, Ltd.
Resumo:
Silica gel chemically modified with 2-aminotiazole groups (SiAT), was used for preconcentration of cupper, zinc, nickel and iron from gasoline, normally used as a engine fuel. Surface characteristics and surface area of the silica gel were obtained before and after chemical modification using FT-IR, Kjeldhal and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques. The experimental parameters, such as shaking time in batch technique, flow rate and concentration of the eluent (HCl-0.25-2.00 mol 1(-1)) and the amount of silica, on retention and elution, have been investigated. Detection limits of the method for cupper, iron, nickel and zinc are 0.8, 3, 2 and 0.1 mug 1(-1), respectively. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in gasoline using flame AAS for their quantification. (C) 2004 Published by Elsevier Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its applications to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study. In this paper, these images were used to confirm the existence of vortex structures in the flow induced by corona discharges on airfoil models. These structures are a possible explanation for the effects of drag reduction and lift force increasing, which have been reported in experiments of plasma assisted Aerodynamics.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This investigation was carried out within the Parana sedimentary basin and involved the sampling of 78 pumped tubular wells for evaluating the hydrochemistry and radioactivity due to the nuclides (238)U, (234)U, (222)Ra, (226)Ra, and (228)Ra in the Brazilian part of Guarani aquifer. Several significant correlations were found involving the geostatic pressure, for instance, specific flow rate, CO(3)(2-), SO(4)(2-) temperature, dissolved O(2), free CO(2), pH, redox potential Eh, conductivity, Na, HCO(3)-, CO(3)(2-) , SI(calcite), Cl(-), F(-), SO(4)(2-), and B. Carbonates precipitation was evidenced by inverse correlation between CO(3)(2-) and Ca, Mg, Sr, and Ba, whereas Na exhibited an opposite trend, dissolving rather than precipitating with increasing CO(3)(2-) concentration. An inverse correlation between 3 and K was found, possibly related to the increasing tendency of K to recombine with the thickness of the clayey layers. HCO(3)-played an important role on Na, Ca, Mg, and Sr dissolution. The dissolved U content and (234)U/(238)U activity ratio data were plotted on a two-dimensional diagram that was successfully utilized on identifying an unreported zone of U accumulation, though not necessarily of economic size and grade. The variability in chemical and radionuclides data indicated an important influence of the underlying Paleozoic sediments in the composition of waters from Guarani aquifer. The available data allowed estimate the groundwater residence time by two U-isotopes disequilibrium methods. Values of 45-61 ka were initially calculated, depending on the adopted porosity (15-20%), but a longer residence time (- 640 ka) was also estimated, which is more compatible with the hydraulic conductivity data in Guarani aquifer and groundwater flow velocity occurring at Milk River aquifer, Alberta, Canada. Such time range agrees with previously reported (14)C ages exceeding 30 ka BP at the more central parts of the Parana sedimentary basin. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry is proposed. For this, the main lines for Cu (324.754 nm), Fe (248.327 nm), Mn (279.482 nm) and Zn (213.857 nm) were selected, and the secondary lines for Ca (239.856 nm), Mg (202.582 nm) and K (404.414 nm) were evaluated. The side pixel registration approach was studied to reduce sensitivity and extend the linear working range for Mg by measuring at wings (202.576 nm; 202.577 nm; 202.578 nm; 202.580 nm: 202.585 nm; 202.586 nm: 202.587 nm; 202.588 nm) of the secondary line. The interference caused by NO bands on Zn at 213.857 nm was removed using the least-squares background correction. Using the main lines for Cu, Fe, Mn and Zn, secondary lines for Ca and K, and line wing at 202.588 nm for Mg, and 5 mL min(-1) sample flow-rate, calibration curves in the 0.1-0.5 mg L-1 Cu, 0.5-4.0 mg L-1 Fe, 0.5-4.0 mg L-1 Mn, 0.2-1.0 mg L-1 Zn, 10.0-100.0 mg L-1 Ca, 5.0-40.0 mg L-1 Mg and 50.0-250.0 mg L-1 K ranges were consistently obtained. Accuracy and precision were evaluated after analysis of five plant standard reference materials. Results were in agreement at a 95% confidence level (paired t-test) with certified values. The proposed method was applied to digests of sugar-cane leaves and results were close to those obtained by line-source flame atomic absorption spectrometry. Recoveries of Ca, Mg, K, Cu, Fe, Mn and Zn in the 89-103%, 84-107%, 87-103%, 85-105%, 92-106%, 91-114%, 96-114% intervals, respectively, were obtained. The limits of detection were 0.6 mg L-1 Ca, 0.4 mg L-1 Mg, 0.4 mg L-1 K, 7.7 mu g L-1 Cu, 7.7 mu g L-1 Fe, 1.5 mu g L-1 Mn and 5.9 mu g L-1 Zn. (C) 2009 Elsevier B.V. All rights reserved.