123 resultados para discrete facility location
Resumo:
Dichotomic maps are considered by means of the stability of the null solution of a class of differential equations with piecewise constant argument via associated discrete equations. Copyright © 2008 Watam Press.
Resumo:
Electromyography is frequently used to measure the activity of masticatory muscles. It requires the precise setting of the electrodes, which demands the accurate location of the muscle to be evaluated. The purpose of this study was to investigate the accuracy of an external method to locate the buccinator muscle. Fifteen human cadavers were evaluated and planes were etermined on the face using anatomic landmarks. An angle (α) was obtained at the intersection of these planes on the central point of buccinator muscle and measured with a protractor. The value of the angle allows locating the central point of buccinator muscle based on anatomic landmarks on the face. Statistical analysis of the collected data indicated an angle of 90° with 95% reliability, thus proving the efficacy of the proposed method.
Resumo:
The objective of this article is to apply the Design of Experiments technique along with the Discrete Events Simulation technique in an automotive process. The benefits of the design of experiments in simulation include the possibility to improve the performance in the simulation process, avoiding trial and error to seek solutions. The methodology of the conjoint use of Design of Experiments and Computer Simulation is presented to assess the effects of the variables and its interactions involved in the process. In this paper, the efficacy of the use of process mapping and design of experiments on the phases of conception and analysis are confirmed.
Resumo:
Molossidae species, Cynomops abrasus (2n = 34, fundamental number, FN = 64), Eumops auripendulus (2n = 42, FN = 62), Molossus rufus (2n = 48, FN = 64), Molossops temminckii (2n = 48, FN = 64), and Nyctinomops laticaudatus (2n = 48, FN = 64), and Phyllostomidae species, Phyllostomus discolor (2n = 32, FN = 60), have karyotypes with different chromosome and fundamental numbers, different localization of constitutive heterochromatin, and different numbers and location of nucleolar organizer regions (NORs). Fluorescence in situ hybridization with a human probe of the telomeric sequence (TTAGGG)n produced fluorescent signals in telomeric regions of the six bat species' chromosomes; in E. auripendulus, pericentromeric signals were also observed in the acrocentric and subtelocentric chromosomes. A relationship between telomeric sequences and NORs, and between telomeric sequences and constitutive heterochromatin was detected in chromosomes bearing NORs in C. abrasus, M. temminckii, N. laticaudatus, and P. discolor. No interstitial signal was observed in the meta- or submetacentric chromosomes of these species. ©FUNPEC-RP.
Resumo:
The objective of this study was to determine the mean distance between the infraorbital foramen and the infraorbital margin, as well as the mean distance between the infraorbital foramen and the piriform aperture on both sides of dry human skulls, with the aim of improving the efficiency in clinical situations, such as surgery and anesthetic procedures. Two hundred ninety-five skulls were used (590 sides), located in the Frankfurt Plane through a craniostat. The measurements were collected by two distinct operators, with a dry tip compass and carried to a caliper. The general mean obtained between the infraorbital foramen and the infraorbital margin was 6.37 mm (±1.69 mm), with a mean of 6,28 mm (±1.79 mm) on the right side and 6.45 mm (±1.76 mm) on the left side. The general mean obtained between the infraorbital foramen and the piriform aperture was 17.67 mm (±1.95 mm), being 17.75 mm (±2.10 mm) on the right side and 17.60 mm (±2.04 mm) on the left side. There were statistically significant differences between the right and left distances of the infraorbital foramen and the infraorbital margin, verified by the Student's-t test. The results of this study allow a more precise location of the infraorbital foramen, particularly as regards the infraorbital margin, since this distance is of relevant importance as a repair point during surgical procedures involving this anatomical structure.
Resumo:
There has been much discussion regarding the ideal position of the condyle in the mandibular fossa. Although the centric relation position (CR) is used as a reference, some authors do not believe that it is physiologic. Thus, the aim of this study was to evaluate in a group of asymptomatic individuals the position of the condyle in the mandibular fossa at maximum intercuspation (MI), with a occlusal splint and with a Lucia jig between the teeth. It was analyzed by means of magnetic resonance imaging (MRI), transcranial radiography imaging and analysis of horizontal axis of rotation from casts mounted on an articulator. The results showed that even if patients had mandibular displacement in positions of CR, habitual maximum intercuspation and with the occlusal splint, confirmed by means of the analysis of the horizontal axis of rotation, the images showed no statistically significant differences among condylar positions. It can therefore be concluded that the positions analyzed were similar and that transcranial radiography seems to be a reliable method for analyzing condylar position.
Resumo:
Introduction. The lateral periodontal cyst, as the name implies, occurs on a lateral periodontal location and is of developmental origin, arising from cystic degeneration of clear cells of the dental lamina. A botryoid odontogenic cyst is considered to be a rare multilocular variant of a lateral periodontal cyst. Case presentation. We report the clinical and histopathologic features of a rare case of botryoid odontogenic cyst found in an edentulous area corresponding to the right lower canine of a 64-year-old African-American woman. A multilocular radiolucency was observed, and surgical removal of the lesion revealed a nodule of rubber-like consistency measuring about 1.5 cm in diameter. Cross-sectioning of the nodule showed that it consisted of various cystic compartments. Histologically, various voluminous periodic acid-Schiff-negative clear cells randomly distributed throughout the cystic epithelium were observed, as well as cell layers showing thickenings generally formed by oval, sometimes entangled plaques. The capsule consisted of fibrous connective tissue and showed rare and discrete foci of a perivascular mononuclear inflammatory infiltrate and reactive bone-tissue fragments. The final diagnosis was botryoid odontogenic cyst. Conclusion: We provide data that allow the reader to establish the differences between botryoid odontogenic cyst, glandular odontogenic cyst, and lateral periodontal cyst, helping with the differential diagnosis. The reader will have the opportunity to review botryoid odontogenic cyst clinical and histopathologic features, including treatment. © 2010 Farina et al; licensee BioMed Central Ltd.
Resumo:
This paper is concerned with ℋ 2 and ℋ ∞ filter design for discrete-time Markov jump systems. The usual assumption of mode-dependent design, where the current Markov mode is available to the filter at every instant of time is substituted by the case where that availability is subject to another Markov chain. In other words, the mode is transmitted to the filter through a network with given transmission failure probabilities. The problem is solved by modeling a system with N modes as another with 2N modes and cluster availability. We also treat the case where the transition probabilities are not exactly known and demonstrate our conditions for calculating an ℋ ∞ norm bound are less conservative than the available results in the current literature. Numerical examples show the applicability of the proposed results. ©2010 IEEE.
Resumo:
As the number of simulation experiments increases, the necessity for validation and verification of these models demands special attention on the part of the simulation practitioners. By analyzing the current scientific literature, it is observed that the operational validation description presented in many papers does not agree on the importance designated to this process and about its applied techniques, subjective or objective. With the expectation of orienting professionals, researchers and students in simulation, this article aims to elaborate a practical guide through the compilation of statistical techniques in the operational validation of discrete simulation models. Finally, the guide's applicability was evaluated by using two study objects, which represent two manufacturing cells, one from the automobile industry and the other from a Brazilian tech company. For each application, the guide identified distinct steps, due to the different aspects that characterize the analyzed distributions. © 2011 Brazilian Operations Research Society.
Resumo:
This paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.
Resumo:
We analyze the chromosomal location of 5S rDNA clusters in 29 species of grasshoppers belonging to the family Acrididae. There was extensive variation among species for the number and location of 5S rDNA sites. Out of 148 sites detected, 75% were proximally located, 21.6% were interstitial, and only 3.4% were distal. The number of 5S rDNA sites per species varied from a single chromosome pair (in six species) to all chromosome pairs (in five species), with a range of intermediate situations. Thirteen chromosomes from eight species carried two 5S rDNA clusters. At intraspecific level, differences among populations were detected in Eyprepocnemis plorans, and some heteromorphisms have also been observed in some species. Double FISH for 5S rDNA and H3 histone gene DNA, performed on 17 of these 29 species, revealed that both markers are sometimes placed in a same chromosome but at different location, whereas they appeared to co-localize in five species (Calliptamus barbarus, Heteracris adpersa, Aiolopus strepens, Oedipoda charpentieri and O. coerulescens). Double fiber-FISH in A. strepens and O. coerulescens showed that the two DNAs are closely interspersed with variable relative amounts of both classes of DNA. Finally, no correlation was observed between the number of 5S and 45S rDNA clusters in 23 species where this information was available. These results are discussed in the light of possible mechanisms of spread that led to the extensive variation in the number of clusters observed for both rDNA types in acridid grasshoppers. © 2011 Springer Science+Business Media B.V.
Resumo:
This paper addresses the H ∞ state-feedback control design problem of discretetime Markov jump linear systems. First, under the assumption that the Markov parameter is measured, the main contribution is on the LMI characterization of all linear feedback controllers such that the closed loop output remains bounded by a given norm level. This results allows the robust controller design to deal with convex bounded parameter uncertainty, probability uncertainty and cluster availability of the Markov mode. For partly unknown transition probabilities, the proposed design problem is proved to be less conservative than one available in the current literature. An example is solved for illustration and comparisons. © 2011 IFAC.
Resumo:
In this paper we propose an accurate method for fault location in underground distribution systems by means of an Optimum-Path Forest (OPF) classifier. We applied the Time Domains Reflectometry method for signal acquisition, which was further analyzed by OPF and several other well known pattern recognition techniques. The results indicated that OPF and Support Vector Machines outperformed Artificial Neural Networks classifier. However, OPF has been much more efficient than all classifiers for training, and the second one faster for classification. © 2011 IEEE.
Resumo:
According to Peirce one of the most important philosophical problems is continuity. Consequently, he set forth an innovative and peculiar approach in order to elucidate at once its mathematical and metaphysical challenges through proper non-classical logical reasoning. I will restrain my argument to the definition of the different types of discrete collections according to Peirce, with a special regard to the phenomenon called premonition of continuity (Peirce, 1976, Vol. 3, p. 87, c. 1897). © 2012 Copyright Taylor and Francis Group, LLC.
Resumo:
The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.