127 resultados para Tomografia de coerência óptica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esse trabalho analisa as refrações do discurso pedagógico que, em diálogo com outros discursos, como os da mídia e da linguística, reflete-os, além de ressignificá-los. Mais especificamente, trata-se da ressignificação que os discursos pedagógicos, postos em diálogo com os discursos da mídia, fazem de conceitos da lingüística; para essa análise tem-se como foco os conceitos de coesão e coerência, esses conceitos são critérios de avaliação dos textos. Quando retirados de suas enunciações e reutilizados nos dias de hoje, esses conceitos são ressignificados de forma a se adaptarem a novas enunciações. Como abordagem metodológica para a realização deste trabalho, tem-se uma análise qualitativa dialógica do livro de Thaís Nicoleti de Camargo, Redação linha a linha (2010) (corpus desse trabalho, que representa o discurso pedagógico). No diálogo proposto sobre os conceitos de coesão e coerência textuais pode-se perceber a ressignificação causada pela nova enunciação em que esses enunciados são reutilizados. Esse trabalho, por valer-se da análise do discurso bakhtiniana, estará sempre voltado ao conceito de diálogo, colocando os discursos em contato; partindo desse ponto, busca-se entender quais discursos dialogam com a produção do discurso pedagógico no livro analisado. Pode-se perceber, na análise dos conceitos de coesão e coerência textuais, que alguns discursos que dialogam com esses enunciados são os discursos de normatização e padronização. É possível dizer que a enunciação em que esses enunciados se produzem remete aos discursos do capitalismo, dos vestibulares, da atribuição de notas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project developed microstructural characterization technics of commercial dualphase and multi-phasic (TRIP) steels that were provided by the automotive industry and are currently used as the raw material for the production of automobiles. Inserted in this context, there is the development of the advanced high strength steels in consonance with the ULSABAVC project, which aims the production of safe, economically viable and efficient in terms of fuel consumption vehicles for the 21st century. The micro-structural characterization of biphasic and multiphase steels was done by the identification and quantification of the coexistent phases. In this item, a special attention was given to the technics that were performed using optic microscopy and scanning electron microscopy. An important contribution to this work was the utilization of different alternative chemical reagents (Beraha, Heat-Tinting technics) in addition to the classical ones (Nital and LePera)already used conventionally by the UNESP's Group of Mechanical, Microstructural and Fractografic Characterization of Materials. The revealed microstructures were correlated with the materials' mechanical properties determined through traction tests, such as ultimate tensile strengths, yield strength and stretching important since the material has structural application in the automotive industry. As a result, it was observed the superiority concerning the studied mechanical properties for the biphasic and multiphasic steels when compared to the conventional carbon steels. Besides, it was perceived a large potential for the industrial scale utilization of the Heat Tinting technics in this field, seen its differentiation of the existent phases and easy reproducibility

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to tridimensionally evaluate pathological and anatomical areas, in apical surgery planning, presents a number of advantages. Cone beam computed tomography (CBCT) was developed for dental applications. This paper aims to present a literature review on CBCT, highlighting its advantages over both conventional computed tomography (CT) and radiography. Moreover, its clinical applications in apical surgery are discussed. LITERATURE REVIEW AND CONCLUSION: Unlikely CT, CBCT captures a volume of data in a single 360º rotation, providing benefits such as higher accuracy, better resolution, reduced scanning time and reduced radiation dose. In the maxillofacial region, CBCT has been mainly used in the assessment of dento-alveolar pathology and oral traumatology. CBCT provides a better diagnosis and quantitative information on periodontal bone levels than conventional radiography. It has also been used for patients requiring surgical facial reconstruction, orthognathic surgery, dental implants, and more complex tooth extractions. Besides that, it seems to be a significant tool in modern endodontic practice, presenting useful applications in apical surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Sol-gel process has facilitated the processing of Organic-Inorganic Hybrid Materials with several scientific applications and technologies. The hybrid combine the advantages of the Sol-gel process with specific characteristics of organic polymers, allowing processing of thin films without fractures or fissures. The incorporation of azo dyes in polymer matrices has been widely used in the investigation of optical properties. The azo dye Disperse Red (DR1) presents optical alterations when exposed to visible or ultraviolet light. The alterations occur due to transitions of their isomers, trans and cis, caused by photoisomerization, due to electronic transitions of azo group (-N=N-), presenting photochromic and/or photorefractive effects. The hybrid system used in this work is the precursor 3- Glycidoxypropyl-Trimethoxi-silane (GPTS), the Tetraethylorthosilicate (TEOS) and DR1 as a dopant. The characterizations were performed using absorption spectroscopy UV-Vis which allowed the identification of the absorption bands and its variations when the samples were treated thermally and/or illuminated by ultraviolet light

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eletronicalceramics are used in many applications such as: multilayer capacitor, transducer, pyroelectric sensors and electrooptic devices. In recent years there has been a growing demand for eletronicalceramics with better performance and functionality. This demand has accelerated the development of synthesis techniques to produce powders with well-defined particle size, shape and crystallinity. The eletronicalceramics in the form of bulk are determined by their performance characteristics of the powders used and the preparation process. So, physical and chemical properties of powders, such as chemical control of stoichiometry, purity, homogeneity, particle size and shape should be observed when choosing the methods of synthesis. Among the techniques used so far, the polymeric precursor method, also known as Pechini, has been considered ideal for the preparation of nanosized powders. Thus, this research project aims to use the polymeric precursor method to prepare powders of lithium tantalate and lanthanum tantalate, with good chemical stability. In this aspect is proposed to investigate the effects of variation of the concentration of europium about the properties of tantalate because doping with Eu3 + indicates that they may occupy different sites in the crystal structure, as in the case of LiTaO3. Effects of things like occupation sites, stability of phases and formation temperature have been previously investigated by the group, which motivated the formulation of this project. Our proposal aims to introduce the Eu3 + LaTaO4 and LiTaO3 and study the structural and optical properties of the powders obtained by Pechini method, as well as correlate these studies with the electrical properties of the material, mainly the Ironelectricty Hysteresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The request of three-dimensional images (3D) of the dentomaxillofacial complex has increased. Hence, new possibilities for assessment, treatment as well as follow-up after treatment have increased their importance with the use of cone beam computed tomography (CBCT). The images in two dimensions (2D) have inherent problems that can be solved with treedimensional images assessment. Objectives: To clarify the main doubts about the operational mechanism of complementary diagnostic method; to explain the advantages and disadvantages, to discuss the effective radiation dose and possible applications in orthodontia. Conclusion: The information generated by 2D images from the CBCT does not show differences that may endanger the orthodontic planning when compared with the images of 2D conventional radiographs. The effective radiation dose received by the patient should not be considered as a limiting factor of the tomography exam request.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)