139 resultados para Sperm preparation method
Resumo:
A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.
Resumo:
The aim of this study was to determine the extent of DNA fragmentation and the presence of single/denatured or double stranded of DNA in sperm with large nuclear vacuoles (LNV) selected by high-magnification. A total of 30 patients had fresh semen samples prepared by discontinuous concentration gradient. Sperm with normal nucleus (NN) and LNV were selected at 8400x magnification and placed in different slides. DNA fragmentation was determined by TUNEL assay. Denatured and double stranded DNA was identified by acridine orange fluorescence method. The percentage of DNA fragmentation in LNV sperm (29%) was significantly higher (P<0.001) than NN sperm (15.8%). Therefore, cleavage of genomic DNA in low molecular weight DNA fragments (mono and oligonucleosomes), and single strand breaks (nicks) in high molecular weight DNA occur more frequently in LNV. Identically, the percentage denatured stranded DNA in sperm with LNV (67.9%) was significantly higher (P <0.0001) than NN sperm (33%). The high level of denatured DNA in sperm with LNV suggests precocious decondensation and disaggregation of sperm chromatin fibers. Our results support an association between LNV sperm and DNA damage, and the routine selection and injection of morphological motile sperm at high magnification for ICSI. The adverse effect (DNA fragmentation or denaturation) leads to concern particularly about the possibility of iatrogenic transmission of genetic abnormalities. Copyright - SBRA - Sociedade Brasileira de Reprodução Assistida.
Resumo:
The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.
Resumo:
The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.
Resumo:
We developed and optimized a simple, efficient and inexpensive method for in vitro culture of peripheral blood lymphocytes from the Brazilian tortoise Chelonoidis carbonaria (Testudinidae), testing various parameters, including culture medium, mitogen concentration, mitotic index, culture volume, incubation time, and mitotic arrest. Peripheral blood samples were obtained from the costal vein of four couples. The conditions that gave a good mitotic index were lymphocytes cultured at 37°C in minimum essential medium (7.5 mL), with phytohemagglutinin as a mitogen (0.375 mL), plus streptomycin/penicillin (0.1 mL), and an incubation period of 72 h. Mitotic arrest was induced by 2-h exposure to colchicine (0.1 mL), 70 h after establishing the culture. After mitotic arrest, the cells were hypotonized with 0.075 M KCl for 2 h and fixed with methanol/acetic acid (3:1). The non-banded mitotic chromosomes were visualized by Giemsa staining. The diploid chromosome number of C. carbonaria was found to be 52 in females and males, and sex chromosomes were not observed. We were able to culture peripheral blood lymphocytes of a Brazilian tortoise in vitro, for the preparation of mitotic chromosomes.
Resumo:
The aim of this study was to establish the parameters of concentration, time and mode of application of citric acid and sodium citrate in relation to root conditioning. A total of 495 samples were obtained and equally distributed among 11 groups (5 for testing different concentrations of citric acid, 5 for testing different concentrations of sodium citrate and 1 control group). After laboratorial processing, the samples were analyzed under scanning electron microscopy. A previously calibrated and blind examiner evaluated micrographs of the samples. Non-parametric statistical analysis was performed to analyze the data obtained. Brushing 25% citric acid for 3 min, promoted greater exposure of collagen fibers in comparison with the brushing of 1% citric acid for 1 minute and its topical application at 1% for 3 min. Sodium citrate exposed collagen fibers in a few number of samples. Despite the lack of statistical significance, better results for collagen exposure were obtained with brushing application of 25% citric acid for 3 min than with other application parameter. Sodium citrate produced a few number of samples with collagen exposure, so it is not indicated for root conditioning.
Resumo:
Cooling of equine semen obtained from some stallions results in lower seminal quality and viability when the seminal plasma (SP) is present. The objective of this study was to evaluate the effect of the removal of SP using a Sperm Filter on the viability of cooled stallion semen. For this purpose, 31 stallions were used. Their ejaculates were divided into three groups: CN, semen was diluted with an extender; FLT, SP was removed by filtration; and CT, SP was removed by centrifugation and cooled to 15°C for 24 hours. Sperm kinetics and plasma membrane integrity were evaluated immediately after collection (T0) and after 24 hours of refrigeration (T1). No difference (P > .05) was noted at T1 for total sperm motility (TM), progressive sperm motility, or plasma membrane integrity when semen samples from all the stallions were analyzed. However, when samples from stallions termed bad coolers were analyzed (TM = <30% at T1), a difference was observed in TM and progressive sperm motility for CN compared with FLT and CT at T1. Sperm recovery was greater when SP was removed using the filter (FLT) to that when the SP was removed by centrifugation (CN) (89% vs. 81%). Thus, we concluded that filtering with a Sperm Filter is an efficient and practical method for removal of SP from stallion ejaculates, with lower sperm loss than centrifugation. We also found that the presence of SP reduces the quality and viability of cooled semen from stallions whose semen is sensitive to the process of refrigeration. © 2013 Elsevier Inc.
Resumo:
Objective: To investigate the influence of the convergence angle of tooth preparation on the fracture load of Y-TZP-based ceramic (YZ-Vita YZ) substructure (SB) veneered with a feldspathic porcelain (VM9-Vita VM9). Methods: Finite element stress analysis (FEA) was performed to examine the stress distribution of the system. Eighty YZ SB were fabricated using a CAD-CAM system and divided into four groups (n = 20), according to the total occlusal convergence (TOC) angle: G6-6° TOC; G12-12° TOC; G20-20° TOC; and G20MOD-20° TOC with modified SB. All SB were veneered with VM9, cemented in a fiber reinforced epoxy resin die, and loaded to failure. Half of the specimens from each group (n = 10) were cyclic fatigued (106 cycles) before testing. Failure analysis was performed to determine the fracture origin. Data were statistically analyzed using Anova and Tukey's tests (α = 0.05). Results: The greatest mean load to fracture value was found for the G20MOD, which was predicted by the FEA. Cyclic fatigue did not significantly affect the load of fracture. Catastrophic failure originating from the internal occlusal surface of the SB was the predominant failure mode, except for G20MOD. Significance: The YZ-VM9 restorations resisted greater compression load than the usual physiological occlusal load, regardless of the TOC angle of preparations. Yet, the G20MOD design produced the best performance among the experimental conditions evaluated. © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Seminal plasma removal, an indispensable step in equine semen cryopreservation, is usually done by centrifugation, but this might cause mechanical damage to sperm. A new method for seminal plasma removal from stallion semen, namely a filter composed of a synthetic hydrophilic membrane (Sperm Filter, BotuPharma, Botucatu, Sao Paulo, Brazil), was recently proposed. The objective of this study was to test the use of the Sperm Filter in the removal of seminal plasma before freezing stallion semen. Ejaculates from 31 stallions were divided into two groups and cryopreserved. In group 1 (G1), seminal plasma was removed with the Sperm Filter, and in group 2 (G2), seminal plasma was removed by centrifugation (600× g for 10 minutes). There were no differences (P < 0.05) between G1 and G2 in sperm kinetic parameters or plasma membrane integrity before or after cryopreservation. However, sperm recovery rate was higher (P < 0.05) for G1 versus G2 (mean ± SD, 89.4 ± 7.4% vs. 80.9 ± 5.5%). Therefore, the Sperm Filter was as efficient as centrifugation in removing seminal plasma from the stallion ejaculate. However, filtering was more practical and had significantly fewer sperm lost than the centrifugation technique. © 2013 Elsevier Inc.
Resumo:
A novel composite formed by interaction of a octa(3-chloropropyl)octasilsesquioxane modified with Purpald®, and its subsequent reaction with silver and hexacyanoferrate (III) (AgHSP), was synthesized and initially characterized by Fourier transform infrared spectra (FTIR) and cyclic voltammetry. The cyclic voltammogram of the modified graphite paste electrode with AgHSP, showed one redox couple with formal potential Eθ'=0.64V (vs Ag/AgCl, KNO3, 1.0 mol L-1; v = 20 mV s-1), attributed to the Fe2+(CN)6/ Fe3+(CN)6 process. The redox couple presents an electrocatalytic response for determination of sulfite. The modified electrode showed a linear response from 7.0×10-5 to 1.0×10-3 mol L-1 with the corresponding equation Y(μA) = 18.05 + 29.983×103 [sulfite], and a correlation coefficient of r=0.999. The method showed a detection limit of 0.115×10-4 mol L-1 with a relative standard deviation of ± 4% (n = 3) and amperometric sensitivity of 29.983×10-3A mol L-1. The modified electrode showed a excellent stability and good reproducibility during experiments. © 2013 by ESG.
Resumo:
Different conditions of extraction using water, a methanol-water mixture and nitric acid solutions were evaluated for speciation of As(iii), As(v), DMA and MMA in plant samples that previously received As(v) after being sown and emergence was investigated. Microwave-assisted extraction (MAE) using diluted nitric acid solutions was also performed for arsenic extraction from chicken feed samples. The separation and determination of arsenic species were performed using HPLC-ICP-MS. The interference standard method (IFS) using 83Kr+ as the IFS probe was employed to minimize spectral interferences caused by polyatomic species, such as 40Ar 35Cl+. The extraction procedures tested presented adequate extraction efficiencies (90%), and the four arsenic species evaluated were found in plant samples. Extractions with diluted nitric acid solution at 90 °C were the most efficient strategy, with quantitative recoveries for all four As species in plant tissues. On the other hand, the methanol-water mixture was the solvent with the lowest extraction efficiency (50-60%). For chicken feed samples, MAE at 100 °C for 30 min resulted in an extraction efficiency of 97% and only As(v) was found, without any species interconversion. The IFS method contributed to improving precision and limits of detection and quantification for all tested extraction procedures. Significant improvements on accuracy were obtained by applying the IFS method and recoveries between 77 and 94%, and 82 and 93% were obtained for plant extracts and chicken feed samples, respectively. This journal is © 2013 The Royal Society of Chemistry.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)