349 resultados para Restorations
Resumo:
The peripheral ossifying fibroma (POF) is a common gingival growth usually arising from the interdental papilla. The anterior maxilla is the most common location of involvement. The etiology and pathogenesis of POF remains unknown. Some investigators consider it a neoplastic process, whereas others argue that it is a reactive process; in either case, the lesion is thought to arise from cells in the periodontal ligament. Trauma or local irritants, such as dental plaque, calculus, microorganisms, masticatory force, ill-fitting dentures, and poor quality restorations, have been implicated in the etiology of POF. The recommended treatment is the excisional biopsy; however, it can leave a defect if the procedure is not followed by a subepithelial connective tissue graft. The main objective of this article was to present a clinical case of excisional biopsy of a POF followed by a subepithelial connective tissue graft to correct the defect caused by the biopsy. The biopsy defect was satisfactorily repaired, and the lesion has not recurred after 6 years of follow-up.
Resumo:
\ The biologic width is an essential dental space that always needs to be maintained to ensure periodontal health in any dental prosthetic restorations. An iatrogenic partial fixed prosthesis constructed in lower posterior teeth predisposed the development of subgingival caries, which induced violation of the biologic width in involved teeth, resulting in an uncontrolled inflammatory process and periodontal tissue destruction. This clinical report describes a periodontal surgical technique to recover a violated biologic width in lower posterior teeth, by crown lengthening procedure associated with free gingival graft procedure, to ensure the possibility to place a modified partial fixed prosthesis in treated area. The procedure applied to recover the biologic width was crown lengthening with some modifications, associated with modified partial fixed prosthesis to achieve health in treated area. The modified techniques in both surgical and prosthetic procedures were applied to compensate the contraindications to recover biologic width by osteotomy in lower posterior teeth. The result, after 4 years under periodic control, seems to achieve the projected goal. Treating a dental diseased area is necessary to diagnose, eliminate, or control all etiologic factors involved in the process. When the traditional methods are not effective to recover destructed tissues, an alternative, compensatory, and adaptive procedure may be applied to restore the sequelae of the disease, applying a restorative method that respects the biology of involved tissues.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to analyze the main aspects that influence the aesthetics of single immediate implant-supported restorations through a literature review on the MEDLINE database. It was observed that immediate implant-supported restorations present clinical success with aesthetic predictability demonstrated by the literature. Proper patient selection and diagnostic and multidisciplinary planning are essential and should be associated to technical ability of professional and knowledge concerning the biology of peri-implant tissues. It is suggested that provisional restoration should be immediately inserted after implant fixation to guide healing of gingival tissues with a proper emergence profile besides psychologic comfort for a patient due to immediate aesthetic reestablishment.
Resumo:
Because of the widespread use of implant-supported restorations and that the success of this treatment depends on the passivity of the different component systems of implant-prosthesis, a literature review was performed to highlight issues related to passivity in framework of implant-supported fixed prosthesis. A search of English-language peer-review literature was completed using MEDLINE database (PubMed) focusing on acceptable levels of passivity, misfit classification, problems related to misfit, methods to evaluate misfit, general factors that affect the passivity, and the biologic tolerance in the presence of misfit. The information obtained in the present review suggested that even if it is hard to obtain an implant-supported prosthesis with complete passivity, the professional should use the technological resources to offer better conditions for their patients. An acceptable clinical level of passivity that does not cause any problem to the biologic, aesthetic, and functional parameters of the patient should be sought.
Resumo:
Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Objectives: the purpose of this study was to investigate the penetration of a conventional adhesive material into enamel bleached with 16% carbamide peroxide and 38% hydrogen peroxide using optical light microscopy.Methods: Extracted human teeth were randomly divided into eight experimental groups with six specimens each, according to the bleaching material and time interval after bleaching and before the bonding procedure. Groups were designated as follows: control group, restorations in unbleached teeth; restorations performed immediately after bleaching; restorations performed 7 days after bleaching; restorations performed 14 days after bleaching; and restorations performed 30 days after bleaching. The length of resin tags was measured with an Axiophot photomicroscope at 400x magnification for the calculation of the proportion of tags of study groups compared to the respective control groups. Analysis of variance was applied for comparison between groups; data were transformed into arcsine (p < 0.05).Results: the specimens of experimental groups, in which restorations were performed 7, 14, and 30 days after bleaching, showed better penetration of adhesive material into enamel than specimens restored immediately after bleaching. There was no statistically significant difference between the bleaching materials employed or in the interaction between bleaching agent and time interval.Conclusions: This suggests that a time interval of at least 7 days should be allowed between enamel bleaching and placement of adhesive bonding agents for accomplishment of composite resin restorations.
Resumo:
Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.
Resumo:
Background. Predicting risk of posteruptive enamel breakdown (PEB) of molar-incisor hypomineralization (MIH) opacity is a difficult but important clinical task. Therefore, there is a need to evaluate these aspects through longitudinal studies.Objective. The aim of this longitudinal study was to analyse the relationship between colours of MIH opacity of children aged 6-12 (baseline) and other clinical and demographic variables involved in the increase in severity of MIH.Materials and methods. A blinded prospective 18-month follow-up was conducted with 147 individuals presenting mild MIH. Tooth-based incidence of increase in severity of MIH (PEB or atypical restorations) was used as dependent measurement. Enamel opacities were recorded according to colour shades of white, yellow and brown, allowing assessment of susceptibility to structural loss over time, according to colour of MIH opacity. Poisson regression models were used to adjust the results for demographic and clinical variables.Results. Brown and yellow MIH opacities were at higher risk for PEB and atypical restorations than those of white ones, even after adjustment for clinical and demographic variables.Conclusion. Teeth presenting mild MIH severity associated with yellow and brown enamel opacities were at high risk for increase in severity of MIH than lighter ones. This result could help clinicians determine a risk-based treatment for children with MIH.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Statement of problem. When clinical fractures of the ceramic veneer on metal-ceramic prostheses can be repaired, the need for remake may be eliminated or postponed. Many different ceramic repair materials are available, and bond strength data are necessary for predicting the success of a given repair system.Purpose. This study evaluated the shear bond strength of different repair systems for metal-ceramic restorations applied on metal and porcelain.Material and methods. Fifty cylindrical specimens (9 X 3 mm) were fabricated in a nickel-chromium alloy (Vera Bond 11) and 50 in feldspathic porcelain (Noritakc). Metal (M) and porcelain (P) specimens were embedded in a polyvinyl chloride (PVC) ring and received I of the following bonding and resin composite repair systems (n=10): Clearfil SE Bond/Clearfil AP-X (CL), Bistite II DC/Palfique (BT), Cojet Sand/Z100 (Q), Scotchbond Multipurpose Plus/Z100 (SB) (control group), or Cojet Sand plus Scotchbond Multipurpose Plus/Z100 (CJSB). The specimens were stored in distilled water for 24 hours at 37 degrees C, thermal cycled (1000 cycles at 5 degrees C to 55 degrees C), and stored at 37 degrees C for 8 days. Shear bond tests between the metal or ceramic specimens and repair systems were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/min. Mean shear bond strength values (MPa) were submitted to 1-way ANOVA and Tukey honestly significant difference tests (alpha=.05). Each specimen was examined under a stereoscopic lens with X 30 magnification, and mode of failure was classified as adhesive, cohesive, or a combination.Results. on metal, the mean shear bond strength values for the groups were as follows: MCL, 18.40 +/- 2.88(b); MBT, 8.57 +/- 1.00(d); MCJ, 25.24 +/- 3.46(a); MSB, 16.26 +/- 3.09(bc); and MCJSB, 13.11 +/- 1.24(c). on porcelain, the mean shear bond strength values ofeach group were as follows: PCL, 16.91 +/- 2.22(b); PBT, 18.04 +/- 3.2(ab); PCJ, 19.54 +/- 3.77(ab); PSB, 21.05 +/- 3.22(a); and PCJSB, 16.18 +/- 1.71(b). Within each substrate, identical superscript letters denote no significant differences among groups.Conclusions. The bond strength for the metal substrate was significantly higher using the Q system. For porcelain, SB, Q, and BT systems showed the highest shear bond strength values, and only SB was significantly different compared to CL and CJSB (P <.05).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)