124 resultados para PHOTONS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are diseases in vertebrates associated with the structure of bone tissue that directly affect the locomotor system of the animal. Being a endoskeleton, the diagnosis of these diseases becomes difficult in vivo. The characterization of the physical structure of the bone tissue of healthy animals becomes a major tool in the diagnosis comparison of live animals. Thus, the objective of this work is to determine the average value of the key physical properties of the bone structure used in the clinical diagnosis, such as: bone density, porosity, and mass attenuation coefficient of 59.6 keV photons of bone tissue and bovine and equine check variations in these values. The samples were provided by the pathology department of the Faculty of Veterinary Medicine and Zootechny of Botucatu-SP, which are of one male equine and one female bovine animals, using the radio and metacarpus, together with these materials were supplied the historic them. They were withdrawn ten samples in cuts of 10cm over the bone . These samples were submitted to the wet method of immersion in water for the density, by the method of attenuation of gamma radiation of radioisotope 241Am, it is estimated the mass attenuation coefficient, and then were dried in the oven for determining the content moisture. In determining the porosity of the samples was tight ground, in order to obtain the density of particles. The results for the mass attenuation coefficient of gamma radiation to the levels of saturated humidity, environment humidity, dry humidity respectively 0289 ± 0039; 0286 ± 0040 and 0297 ± 0042. And the density of particles was 2.2691 g/cm3

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due the differences between interaction physics process with matter for protons and photons, the proton beam tomography (pCT) has some vantages to comparison with conventional tomography. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. The pCT allow not only view the internal structure of an object without destroying it, but also directly measure of volume density of electrons. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. At the same time, there are many scientific and technical aspects to a detailed study: the capacity and limitations of the pCT methods are not well clarified. Through computations, based on Monte Carlo Method was carried out a detailed study of the contribution of non-elastic nuclear spreading, and together was compared with an analytical model for the deflection angle and the lateral deflection of protons in the target volume. The programs used were SRIM 2006 code and MCNPX v.2.50 code

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imaging diagnosis is a medical specialty that uses imaging techniques to perform diagnosis. In diagnostic imaging various methods are used such as direct absorption of photons - SPA and DPA, radiographic photometry, the dual-energy radiographic absorptiometry - DEXA, ultrasound, magnetic resonance imaging, computed tomography and optical densitometry in radiographic image. The dog can be considered one of the most widely used animals in the study of bone diseases and searching for a reliable diagnosis, although not an ideal model for the study of osteoporosis, because these animals tend not to develop a decrease in bone mineral density. The objective of this study was to analyze bone density in mongrel dogs from the determination of the variation of density along the radio-ulna bone and also the mean value related to gender, weight and age of individuals. The density analysis carried out showed that for this data set, there is a significant difference in the case of gender and age of the animal and may generalize according to these variables. The only significant difference was found in the weight, which increases bone mass is related to weight gain through the growth of the animal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to analyze the stability of the rotational motion’s artificial satellite using the Routh Hurwitz Algorithm (CRH) and the quaternions to describe the satellite’s attitude. This algorithm allows the investigation of the stability of the motion using the coefficients of the characteristic equation associated with the equation of the rotational motion in the linear form. The equations of the rotational motion are given by the four cinematic equations for the quaternion and the three equations of Euler for the spin velocity’s components. In the Euler equations are included the components of the gravity gradient torque (TGG) and the solar radiation torque (TRS). The TGG is generated by the difference of the Earth gravity force direction and intensity actuating on each satellite mass element and it depends on the mass distribution and the form of the satellite. The TRS is created by changing of the linear momentum, which happens due to the interactions of solar photons with the satellite surface. The equilibrium points are gotten by the equation of rotational motion and the CRH is applied in the linear form of these equations. Simulations are developed for small and medium satellites, but the gotten equilibrium points are not stable by CRH. However, when some of the eigenvalues of the characteristic equation are analyzed, it is found some equilibrium points which can be pointed out as stables for an interval of the time, due to small magnitude of the real part of these eigenvalue

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the recent years, the use of proton beams in radiotherapy has been an outstanding progress (SMITH, 2006). Up to now, computed tomography (CT) is a prerequisite for treatment planning in this kind of therapy because it provides the electron density distribution required for calculation of dose and the interval of doses. However, the use of CT images for proton treatment planning ignores fundamental differences in physical interaction processes between photons and protons and is, therefore, potentially inaccurate (SADROZINSKI, 2004). Proton CT (pCT) can in principle directly measure the density distribution needed in a patient for the dose distribution (SCHULTE, et al, 2004). One important problem that should be solved is the implementation of image reconstruction algorithms. In this sense, it is necessary to know how the presence of materials with different density and composition interfere in the energy deposition by ionization and coulomb excitation, during its trajectory. The study was conducted in two stages, was used in both the program SRIM (The Stopping and Range of Ions in Matter) to perform simulations of the interaction of proton beams with pencil beam type. In the first step we used the energies in the range of 100-250 MeV (ZIEGLER, 1999). The targets were set to 50 mm in length for the beam of 100 MeV, due to its interaction with the target, and short-range, and 70 mm for 150, 200 and 250 MeV The target was composed of liquid water and a layer of 6 mm cortical bone (ICRP). It were made 9 simulations varying the position of the heterogeneity of 5 mm. In the second step the energy of 250 MeV was taken out from the simulations, due to its greater energy and less interaction. The targets were diminished to 50 mm thick to standardize the simulations. The layer of bone was divided into two equal parts and both were put in the ends of the target... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technologies are rapidly developing, but some of them present in the computers, as for instance their processing capacity, are reaching their physical limits. It is up to quantum computation offer solutions to these limitations and issues that may arise. In the field of information security, encryption is of paramount importance, being then the development of quantum methods instead of the classics, given the computational power offered by quantum computing. In the quantum world, the physical states are interrelated, thus occurring phenomenon called entanglement. This study presents both a theoretical essay on the merits of quantum mechanics, computing, information, cryptography and quantum entropy, and some simulations, implementing in C language the effects of entropy of entanglement of photons in a data transmission, using Von Neumann entropy and Tsallis entropy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Computação - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We establish bounds on the mass scale of effective interactions between fermions and photons using the OPAL data for the reaction e+e-→γγ at √s=91.22 GeV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Frequency upconversion (UC) processes involving energy transfer (ET) among Nd 3+ and Pr 3+ ions in a fluoroindate glass are reported. In a first experiment, the excitation of Pr 3+ [transition 3H 4→ 1D 2] and of Nd 3+ [transition 4I 9/2→( 2G 7/2+ 4G 5/2)] was achieved with a dye laser operating in the 575-590 nm range. In a second experiment, the Nd 3+ ions were excited with the second harmonic of a Nd: YAG laser at 532 nm. The ET processes leading to UC in both experiments were studied by monitoring the blue fluorescence decay at 480 nm due to the transition 3P 0→ 3H 4 in Pr 3+. In the more relevant UC process, quartets of ions (Nd-Nd-Pr-Pr) are excited due to absorption of three laser photons by two Nd 3+ ions which transfer their energy to two Pr 3+ ions. Each Pr 3+ ion promoted to the 3P 0 level decays to the ground state emitting one photon in the blue region. This conclusion was achieved investigating the dependence of the UC fluorescence intensity as a function of laser intensity, samples concentrations, and temporal behavior of the UC signal. Other UC processes involving nonisoionic groups of three ions are also reported. © 2002 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluate the potential for searching for isosinglet neutral heavy leptons (N), such as right-handed neutrinos, in the next generation of e+e- linear colliders, paying special attention to contributions from the reaction γe→WN initiated by photons from beamstrahlung and laser back-scattering. We find that these mechanisms are both competitive and complementary to the standard e+e-→vN annihilation process for producing neutral heavy leptons in these machines and greatly extends the search range over HERA and LEP200.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We estimate the attainable limits on the coupling of a nonstandard Higgs boson to two photons taking into account the data collected by the Fermilab collaborations on diphoton events. We based our analysis on a general set of dimension-6 effective operators that give rise to anomalous couplings in the bosonic sector of the standard model. If the coefficients of all blind operators have the same magnitude, indirect bounds on the anomalous triple vector-boson couplings can also be inferred, provided there is no large cancellatton in the Higgs-gamma-gamma coupling.