466 resultados para Oblique ligament
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of the study was to evaluate the biocompatibility of RoekoSeal sealer Roeko (Dental Products, Langenau, Germany) with the periapical tissues of dogs and compare it with AH Plus sealer (Dentsply/De Trey, Konstanz, Germany). The pulps of 32 root canals were removed, the apical cementum layer perforated, the biomechanical preparation performed, and the root canals filled by lateral condensation technique. Ninety days after the surgery, the animals were euthanized, the bone with teeth removed, and the samples prepared for histopathological analysis. In group 1 (RoekoSeal Automix), deposition of mineralized tissue was observed, with complete newly mineralized apical formed tissue in 43.8% and partial sealing in 56.2%. In group 2 (AH Plus), in 12.5% there was complete newly mineralized apical formed tissue, in 75% the sealing was partial, and in 12.5% there was no sealing (p < 0.05). There were no differences between the groups in relation to the inflammatory infiltrate; thickness of the periodontal ligament; and the resorption of dentin, cementum or bone (p > 0.05).
Resumo:
Objective: Control of microleakage represents a challenge for posterior composite restorations. The technique for composite placement may reduce microleakage. The null hypothesis of this in vitro study was that centripetal incremental insertion of composite resin would result in less microleakage than that obtained with the oblique incremental technique or bulk technique. Method and Materials: Standardized Class 2 preparations were made in 60 caries-free extracted third molars and randomly assigned to 3 groups ( n = 20): ( 1) oblique incremental insertion technique ( control), ( 2) centripetal incremental insertion technique, and ( 3) bulk insertion. The teeth were restored with a total-etch adhesive and micro-hybrid composite resin. The specimens were isolated with nail varnish except for a 2-mm-wide area around the restoration and then thermocycled ( 1,000 thermal cycles, 5 degrees C/ 55 degrees C; 30-second dwell time). The specimens were immersed in an aqueous solution of 50% silver nitrate for 24 hours, followed by 8 hours of immersion in a photo-developing solution and subsequently evaluated for leakage. The microleakage scores ( 0 to 4) obtained from the occlusal and cervical walls were analyzed with median nonparametric tests ( P <.05). Results: The null hypothesis was rejected. All techniques attained statistically similar dentin microleakage scores ( P =.15). The centripetal insertion technique displayed significantly less microleakage than the oblique technique at the enamel margins ( P =.04). Conclusion: None of the techniques eliminated marginal microleakage in Class 2 preparations. However, in occlusal areas, the centripetal technique performed significantly better than the other techniques.
Resumo:
During knee ligament reconstruction, the tendon graft is tensioned to prevent the occurrence of excessive graft elongation during the postoperative period. Tensioning may be achieved by applying a cyclic or static load to the graft during fixation. Although this procedure is part of the surgery, there is no consensus in international literature regarding ideal tension levels to be used in this procedure. This study was conducted on 10 tendons of the human gracilis muscle and 10 tendons of semitendinosus muscle removed from five male cadavers whose mean age was 20.8 years. These tendons underwent 10 in vitro strain cycles at three levels of deformation (2.5, 3, and 4%) and the value of the deforming load used for each cycle was recorded. The statistical analysis demonstrated that in order to attain the same level of deformation during the 10 cycles there was a reduction in the value of strain applied to the graft, observed at the three levels of deformation. It was concluded that the semitendinosus tendon presents a more uniform mechanical behavior and that there is a need for new graft tensioning protocols that consider the force associated with deformation.
Resumo:
The differentiation of spermatids in Hoplias malabaricus is characterized by chromatin compaction, flagellum development, nuclear rotation, nuclear fossa formation, and excess cytoplasm elimination. In the resulting spermatozoon, the head is round and the nucleus contains chromatin compacted in thick filaments, peripherically arranged, to a central electron-lucent area. The acrosome is absent. The nuclear fossa is eccentric but not pronounced. The proximal centriole penetrates it and is oblique to the flagellum. The long midpiece has several converging elongate vesicles, forming membranous hoops in the initial segment of the flagellum, but has no cytoplasmic channel. The mitochondria are elongate and branched or C-shaped and located around the initial segment of the axoneme. The lateral flagellum does not show lateral projections. The ultrastructural characteristics of H. malabaricus spermatozoa are similar to the Cypriniformes. (C) 2001 the Fisheries Society of the British Isles.
Resumo:
Spermatozoa ultrastructure was studied in five marines (Paralonchurus brasiliensis, Larimus breviceps, Cynoscion striatus, Micropogonias furnieri, Menticirrhus americanus, Umbrina coroides, Stellifer rastrifer), and one freshwater (Plagioscion squamosissimus) species of Sciaenidae and one species of Polynemidae (Polydactylus virginicus). The investigation revealed that, in all species, spermatozoa display a round head, a nucleus containing highly condensed, filamentous chromatin clusters, no acrosome, a short midpiece with a short cytoplasmic channel, and a flagellum showing the classic axoneme structure (9 + 2) and short irregular lateral fins. In Sciaenidae, the spermatozoa are type II, the flagellar axis is parallel to the nucleus, the lateral nuclear fossa is double arched, the centriolar complex is outside the nuclear fossa, the proximal centriole is anterior and perpendicular to the distal centriole, and no more than ten spherical (marine species) or elongate (freshwater species) mitochondria are observed. Polynemidae spermatozoa are of the intermediate type with the flagellar axis eccentric to the hemi-arc-shaped nucleus, and exhibit no nuclear fossa, the centriolar complex close to the upper nuclear end, the proximal centriole lateral and oblique to the distal centriole, and one large ring-shaped mitocondrion. The data available show that no characteristic is exclusively found in the spermatozoa of members of the Sciaenidae family when compared to other Percoidei with type II spermatozoa. However, three characteristics were exclusively found in Polynemidae: (1) the hemi-arched nucleus; the positioning of the centrioles; and (2) the ring-shaped mitocondrion. The interrelationships between Sciaenidae and Polynemidae as well as between these two families and other Percoidei are herein discussed. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aimed to compare trunk muscle co-activation pattern during exercises using an oscillatory pole. Twelve volunteers participated in this study, in which they performed three different exercises. EMG activity of internal oblique (IO), external oblique (EO), rectus abdominis (RA), multifidus (MU) and iliocostalis lumborum (IL) was collected. The EMG signals were analyzed in time domain (RMS) and muscles activation ratios were computed as follow: anterior-posterior (A/P=RA+EO+IO/MU+IL), MU/IL and OE/OI. The bilateral oscillation of the pole in frontal plane (exercise II) promoted a higher value of MU/IL ratio than unilateral oscillation of the pole in sagital plane (exercise III). Also, the bilateral oscillation of the pole in frontal plane (exercise II) and the unilateral oscillation of the pole in sagital plane (exercise III) caused higher values of the IO/EO than bilateral oscillation of the pole in transversal plane (exercise I). Thus, the exercises II and III required higher activation of trunk stabilizer muscles, being more indicate for training, which aims higher recruitment of these muscles in daily activities.
Resumo:
Objective: Hand-held flexible poles which are brought into oscillation to cause alternating forces on trunk, are advocated as training devices that are supposed to solicit increased levels of stabilizing trunk muscle activity. The aim of this study was to verify this claim by comparing electromyographic (EMG) activity of trunk muscles during exercises performed with a flexible pole and a rigid pole.Methods: Twelve healthy females performed three different exercises with flexible and rigid poles. EMG activity of iliocostalis lumborum (IL), multifidus (MU), rectus abdominis (RA), external oblique (EO) and internal oblique (IO), and was continuously measured. The EMG signals were analyzed in time domain by calculation of the Root Mean Square (RMS) amplitudes over 250 ms windows. The mean RMS-values over time were normalized by the maximum RMS obtained for each muscle.Results: The IO showed a 72% greater EMG activity during the exercises performed with the flexible pole than with the rigid pole (p = 0.035). In exercises performed in standing, the IO was significantly more active than when sitting (p = 0.006).Conclusion: As intended, the cyclic forces induced by the oscillating pole did increase trunk muscle activation. However, the effect was limited and significant for the IO muscle only.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A lesão do ligamento cruzado anterior (LCA) do joelho acarreta alterações somatosensoriais em função da perda de informações provenientes dos mecanorreceptores presentes no LCA. Esses receptores constituem importante fonte de informação sensorial, afetando o desempenho de vários atos motores, dentre os quais o controle postural. O estudo objetivou analisar o controle postural de indivíduos com joelhos normais e com lesão unilateral do LCA. Participaram 15 voluntários com lesão do LCA (grupo lesado) e 15 voluntários com joelhos normais (grupo controle). O controle postural foi analisado por plataforma de força, sendo o voluntário instruído a assumir a situação experimental em apoio unipodal direito e esquerdo, posicionado no centro da plataforma de modo estático e com os olhos fechados. A plataforma de força forneceu informações de forças e momentos no eixo vertical e horizontal, a partir das quais foi obtida a área de deslocamento do centro de pressão nas direções ântero-posterior e médio-lateral. Os resultados mostram que indivíduos com lesão do LCA apresentaram maior amplitude média de oscilação comparados aos do grupo controle, sugerindo que o deficit no controle postural seja devido à perda de informações proprioceptivas nos indivíduos com LCA. Esses resultados têm implicações para a abordagem clínica de indivíduos com lesão do LCA.
Resumo:
Computer systems are used to support breast cancer diagnosis, with decisions taken from measurements carried out in regions of interest (ROIs). We show that support decisions obtained from square or rectangular ROIs can to include background regions with different behavior of healthy or diseased tissues. In this study, the background regions were identified as Partial Pixels (PP), obtained with a multilevel method of segmentation based on maximum entropy. The behaviors of healthy, diseased and partial tissues were quantified by fractal dimension and multiscale lacunarity, calculated through signatures of textures. The separability of groups was achieved using a polynomial classifier. The polynomials have powerful approximation properties as classifiers to treat characteristics linearly separable or not. This proposed method allowed quantifying the ROIs investigated and demonstrated that different behaviors are obtained, with distinctions of 90% for images obtained in the Cranio-caudal (CC) and Mediolateral Oblique (MLO) views.
Resumo:
Different types of laser have been widely studied for applicability in the oral health area. In the endodontic area, investigations with some types of laser have been conducted to establish safe parameters for clinical application in root canals. However, it has not been duly explained whether the temperature increase caused by laser irradiation could cause alteration in the temperature on the external surface of the root and, consequently, alterations in the cells of the periodontal ligament, causing resorption and even loss of the dental element. The proposal in this paper was to gauge the external root temperature in the apical and cervical regions of the roots of human teeth during root canal irradiation with Nd:yttrium aluminum garnet (YAG) and Er:YAG lasers using different parameters. The novel approach of this paper is the use of the technique of laser applications along the total length of the root canal with series of repetitive irradiation, however, using time of 1 s of irradiation associated with 1 s off to avoid cumulative thermal effects. Experimental results confirm the accuracy of the parameters and exposure regimen obtained. All the parameters used in this paper are acceptable from a clinical as well as a biological point of view. (C) 2009 Laser Institute of America.