114 resultados para Microstrip transmission line
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
Double three-phase transmission lines are analyzed in this paper using a modal transformation model. The main attribute of this model is the use of a single real transformation matrix based on line geometrical characteristics and the Clarke matrix. Because of this, for any line point, the electrical values can be accessed for phase domain or mode domain using the considered transformation matrix and without convolution methods. For non-transposed symmetrical lines the errors between the model results and the exact modes are insignificant values. The eigenvector and eigenvalue analyses for transposed lines search the similarities among the three analyzed transposition types and the possible simplifications for a non-transposed case.
Resumo:
This study describes a technical analysis of a four-phase line as a transmission system alternative. An analysis in the frequency and the time domains is performed to evaluate the electrical characteristics and the transient response of a generic four-phase system compared with those of a conventional three-phase transmission system. The technical features of this non-conventional system are discussed and reviewed based on the current literature. Thus, a new analysis of the four-phase system is presented that emphasises several technical characteristics that have not been discussed in previous studies.
Resumo:
Three-phase three-wire power flow algorithms, as any tool for power systems analysis, require reliable impedances and models in order to obtain accurate results. Kron's reduction procedure, which embeds neutral wire influence into phase wires, has shown good results when three-phase three-wire power flow algorithms based on current summation method were used. However, Kron's reduction can harm reliabilities of some algorithms whose iterative processes need loss calculation (power summation method). In this work, three three-phase three-wire power flow algorithms based on power summation method, will be compared with a three-phase four-wire approach based on backward-forward technique and current summation. Two four-wire unbalanced medium-voltage distribution networks will be analyzed and results will be presented and discussed. © 2004 IEEE.
Resumo:
This paper proposes a dedicated algorithm for lation of single line-to-ground faults in distribution systems. The proposed algorithm uses voltage and current phasors measured at the substation level, voltage magnitudes measured at some buses of the feeder, a database containing electrical, operational and topological parameters of the distribution networks, and fault simulation. Voltage measurements can be obtained using power quality devices already installed on the feeders or using voltage measurement devices dedicated for fault location. Using the proposed algorithm, likely faulted points that are located on feeder laterals geographically far from the actual faulted point are excluded from the results. Assessment of the algorithm efficiency was carried out using a 238 buses real-life distribution feeder. The results show that the proposed algorithm is robust for performing fast and efficient fault location for sustained single line-to-ground faults requiring less than 5% of the feeder buses to be covered by voltage measurement devices. © 2006 IEEE.
Resumo:
Male sheep of reproductive age were distributed into three groups: GI, a sheep inoculated (oral) with 2.0×105 oocysts of the P strain of Toxoplasma gondii; GII, a sheep infected (subcutaneous) with 1.0×106 tachyzoites of the RH strain of T. gondii; and GIII, a sheep kept as a control (not infected). After the inoculation of the males, 12 breeding ewes, which were not pregnant and which were serologically negative for reproductive diseases (particularly toxoplasmosis), were distributed into three groups, synchronized, and subsequently exposed to natural mating with previously inoculated males. The distribution was as follows: five ewes that underwent natural mating with the GI male, five ewes that were exposed to natural mating with the GII male, and two ewes that were mated with the non-infected male (control). Serum samples of all the ewes were collected on days -30, -14, -7, -1, and 0 (days before natural mating) and on days 1, 3, 5, 7, 11, 14, and weekly until birth; the presence of serum antibodies against T. gondii was assessed by IFAT. Using a bioassay and PCR, T. gondii was isolated from the semen of the infected reproducing sheep before mating. Following natural mating, 5 of the 12 females displayed antibodies specific for T. gondii; of these animals, two of the ewes underwent natural mating with the male inoculated with oocysts (GI) and three with the male infected with tachyzoites (GII). One of the females that displayed antibodies specific to this coccidian and that underwent natural mating with the GII sheep had a macerated fetus on the 70th day following coverage. Using a bioassay after the birth, it was possible to isolate T. gondii from samples of the pool of tissues from the five females that seroconverted after natural mating and from their respective lambs. Using PCR, the DNA of T. gondii was isolated from the pool of tissues from one and two females exposed to natural mating with the reproductive males infected with the oocysts and tachyzoites, respectively. Using this technique, it was also possible to diagnose the presence of the parasite in the pool of tissues from the lambs of one female that underwent natural mating with the male sheep infected with oocysts. These results demonstrated the sexual transmission of T. gondii in the sheep species with consequent vertical transmission to their lambs. © 2013 Elsevier B.V.
Resumo:
In this paper, a hybrid heuristic methodology that employs fuzzy logic for solving the AC transmission network expansion planning (AC-TEP) problem is presented. An enhanced constructive heuristic algorithm aimed at obtaining a significant quality solution for such complicated problems considering contingency is proposed. In order to indicate the severity of the contingency, 2 performance indices, namely the line flow performance index and voltage performance index, are calculated. An interior point method is applied as a nonlinear programming solver to handle such nonconvex optimization problems, while the objective function includes the costs of the new transmission lines as well as the real power losses. The performance of the proposed method is examined by applying it to the well-known Garver system for different cases. The simulation studies and result analysis demonstrate that the proposed method provides a promising way to find an optimal plan. Obtaining the best quality solution shows the capability and the viability of the proposed algorithm in AC-TEP. © Tübi̇tak..
Resumo:
Estudos citogenéticos foram desenvolvidos em Prochilodus lineatus (Valenciennes 1836), os quais descrevem um interessante sistema de pequenos cromossomos supranumerários. O objetivo deste trabalho foi estudar a frequência e morfologia dos cromossomos B em indivíduos a partir da linhagem parental e os padrões de herança destes elementos em indivíduos obtidos a partir de cruzamentos controlados na espécie P. lineatus. A taxa de transmissão dos cromossomos B revelaram um kB=0,388 para o tipo acrocêntrico, kB=0,507 para o tipo metacêntrico e kB=0,526 submetacêntrico. Os resultados obtidos levantam hipóteses de que os cromossomos B do tipo acrocêntrico se encontram em fase de extinção, enquanto que os supranumerários do tipo metacêntrico e submetacêntrico encontram-se em fase de neutralização, seguindo uma taxa de transmissão Mendeliana.