146 resultados para Liquids.
Resumo:
Pós-graduação em QuÃmica - IQ
Resumo:
Generally most plastic materials are intrinsically hydrophobic, low surface energy materials, and thus do not adhere well to other substances. Surface treatment of polymers by discharge plasmas is of great and increasing industrial application because it can uniformly modify the surface of sample without changing the material bulk properties and is environmentally friendly. The plasma processes that can be conducted under ambient pressure and temperature conditions have attracted special attention because of their easy implementation in industrial processing. Present work deals with surface modification of polycarbonate (PC) by a dielectric barrier discharge (DBD) at atmospheric pressure. The treatment was performed in a parallel plate reactor driven by a 60Hz power supply. The DBD plasmas at atmospheric pressure were generated in air and nitrogen. Material characterization was carried out by contact angle measurements, and X-ray photoelectron spectroscopy (XPS). The surface energy of the polymer surface was calculated from contact angle data by Owens-Wendt method using distilled water and diiodomethane as test liquids. The plasma-induced chemical modifications are associated with incorporation of polar oxygen and nitrogen containing groups on the polymer surface. Due to these surface modifications the DBD-treated polymers become more hydrophilic. Aging behavior of the treated samples revealed that the polymer surfaces were prone to hydrophobic recovery although they did not completely recover their original wetting properties.
Resumo:
Conselho Nacional de Desenvolvimento CientÃfico e Tecnológico (CNPq)
Resumo:
The objective of this study was to evaluate the coverage of spray droplets on coffee plants as well as their deposition using a sprayer with and without adaptation of an auxiliary branch for tall plants. The experiment was conducted following a randomized block design with six treatments and four replications to evaluate the percentage of coverage for the spraying liquids in water sensitive paper fixed at four quadrants and two heights (lower and upper) of the plants, and the spray deposit with metallic marker (MnSO4) on sheets in the same positions of the water sensitive paper in two spray volumes (450 and 750 L h(-1)). The experiment was conducted in October 2011 in the town of Patroc nio-MG, and the experimental plots consisted of 30 plants of Catua IAC-99, with approximately 12 years of age and average height of 3.50 meters. The experiments were conducted following a randomized block design with six treatments and four replications to evaluate the coverage and deposition, in two spray volumes (450 and 750 L ha(-1)). Leaves were collected in four positions and also at the top four in the lower canopy. The results of the evaluations were analysed statistically by F test and for comparison of means by Tukey test at 5% probability. The auxiliary branch installed at the rear of the equipment is the most suitable when compared to use of equipment without this feature or installed in the front of the equipment. Furthermore, the application volume of 450 L ha(-1) results in coverages and deposits of spraying liquids equivalents to volume of 750 L ha(-1), considered sufficient according to the parameters evaluated.
Resumo:
The present work aimed to evaluate the volumetric distribution profiles, droplet spectra, surface tension, contact angle of droplet and the spraying liquid deposition over the peanut leaves (Arachis hypogaea L.), under artificial rain, in comparison with deposition without rain, using two hydraulic nozzle models of plain fan and insecticide spraying liquids with and without adjuvants addition. It were used a patternator for volumetric distribution analysis, a laser particles analyzer to evaluate droplet spectra produced by SF 110015 and XR 110015 nozzles and tensiometer for droplet tension and contact angle. The spraying liquids evaluated were: water, lambda-cialotrina, lambda-cialotrina + nitrogen fertilizer and lambda-cialotrina + mineral oil. All experiments followed a completely randomized design. Data were submitted to variance analysis by F test and the means comparisons by Scott-Knott test at 5% of probability. According to the results, it must be considered the maximum spacing in spray boom usage of 50 and 90 cm between the nozzles SF110015 and XR110015, respectively. The adjuvants effects on droplet spectra have shown addicted to the nozzle and the product used, and the adjuvants addition to the spraying liquid affected the potential risk of drift; The Volumetric Median Diameter (VMD) of produced droplets by nozzles filled into thin class and were not influenced by the adjuvants. The nitrogen fertilizer adjuvant may be indicated to promote improvements on coverage and droplet deposition on target.
Resumo:
Background. Reduced surface tension of liquids results in higher surface wetting ability and diffusivity by the substrate. Objectives. The objective of this study was to evaluate the influence of the Grander Technology in reducing the surface tension of adhesive systems. Methods. Two adhesive systems (self-etch and total-etch) were modified by physical contact with the Grander system Flexible unit to revitalize water, for 48 h. Surface tension of adhesive systems and water in normal and grander-modified conditions was measured with a goniometer. Results. The results showed a reduction of surface tension for all conditions grander-modified between 3-15%. Conclusions. Grander Technology was effective in reducing the surface tension of the Single Bond and Clearfil SE Bond adhesive systems. Clinical significance. Grander technology was employed to restructure the molecular structure of water-based adhesive systems, which can increase their wetness capacity and therefore ensure a greater diffusibility.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de NÃvel Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Translation, cross-cultural adaptation and validation of the DYMUS questionnaire for the assessment of dysphagia in multiple sclerosis. The original English version of the DYMUS was translated using the forward-backward technique, cross-culturally adaptated, pilot-tested in 40 patients, and then applied to 100 multiple sclerosis patients to assess the reliability and construct validity. Construct validity was assessed by Mann–Whitney test and Spearman’s correlation coefficient (rs). The internal consistency of the questionnaire was evaluated using Cronbach’s alpha coefficient and inter-item correlation. DYMUS-BR internal consistency was high (Cronbach’s alpha= 0.72); Cronbach’s alpha was 0.65 for the ‘dysphagia for solids’ subscale and 0.67 for the ‘dysphagia for liquids’ subscale and positive inter-item correlations was found between all items, except for weight loss question. Significant association (p<0.001) and correlation (rs = 0,357; p = 0.01) was found between DYMUS-BR and dysphagia self-assessment. The DYMUS-BR questionnaire maintained the characteristics of that originally described, demonstrating to be a reliable, valid, easy and consistent tool to be used by health professionals for preliminary selection of Brazilian MS patients who need more specific instrumental analyses of swallowing.
Resumo:
Pós-graduação em Agronomia (Entomologia AgrÃcola) - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilÃbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades fÃsicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada hÃbrida em dentina humana e bovina. A tensão superficial de quatro diferentes lÃquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro lÃquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada hÃbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatÃstica de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os lÃquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.