175 resultados para Leg Length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the present study, 107 specimens of Atlantoraja castelnaui, 188 of A. platana, and 770 of A. cyclophora, were obtained by commercial vessels operating in Southeastern Brazil from March 2005 to April 2006. Males of A. castelnaui ranged from 17.9-111.0 cm and females from 17.4-116.0 cm total length. Males of A. platana ranged from 13.1-70.0 cm and females from 12.5-76.0 cm total length. Males of A. cyclophora ranged from 13.3-58.5 cm and females from 11.5-68.0 cm total length. Length-weight curves were sexually dimorphic in the three species. The analysis of the angular coefficient (b) demonstrated that growth (in weight) in relation to length was allometric (b>3) in males of A. castelnaui and A. platana, while isometric (b = 3) in females of these species. Conversely, growth of A. cyclphora was isometric in males, while in females it was allometric (b>3). The condition factor varied significantly throughout the year only in females of A. castelnaui.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the penetration (tags) of adhesive materials into enamel etched with phosphoric acid or treated with a self-etching adhesive, before application of a pit-and-fissure sealant. MATERIALS AND METHODS: The sample comprised six study groups with six specimens each. Before pit-and-fissure sealing with the materials Clinpro SealantTM (Groups I and II), Vitro Seal ALPHA (Groups III and IV) and Fuji II LC (Groups V and VI), the teeth in Groups I, III, and V were etched with 35% phosphoric acid for 30 seconds. Teeth in Groups II, IV, and VI received application of the self-etching adhesive Adper Prompt L-Pop. The treated teeth were sectioned buccolingually, ground to 100-microm thickness, decalcified, and analyzed by conventional light microscopy at 400x magnification. RESULTS: The teeth etched with phosphoric acid exhibited significantly greater penetration than specimens treated with self-etching adhesive. CLINICAL SIGNIFICANCE: When compared with enamel treated with a self-etching adhesive, the penetration (tags) of adhesive materials into enamel was greater when applied on enamel etched with phosphoric acid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the torque, torque ratio (Hamstrings:Quadriceps - H:Q), electromyographic (EMG) activity and EMG ratio (knee flexors:knee extensors EMG) in soccer players (SG, N=10) and active subjects (AG, N=10). Subjects performed three maximal voluntary isometric knee extensions and flexions at 45° and 90° to determine the peak torque and EMG activity. Torque and EMG activity of the knee flexor (biceps femoris [BF] and semitendinosus [ST]) were divided by the torque and EMG activity of the knee extensor (vastuls lateralis [VL] and rectus femoris [RF]) to calculate torque ratios (H:Q) and EMG ratios (BF:VL, BF:RF, ST:VL, ST:RF). The flexion torque was significantly higher for SG (p<0.05) in 45° and 90°. EMG activity for SG was significantly higher in agonist contractions for VL, RF and ST, and significantly lower in antagonist contractions for RF and ST when compared to AG Torque and EMG ratios were similar between groups and there were good correlations between torque ratio and BF:VL ratio (r=0.71, p=0.02) and BF:RF ratio (r=0.81, p=0.004) at 45. The EMG results could overestimate the joint balance calculated using torque ratios. Differences in recruitment pattern between soccer players and non-athletes can be related to the training routines and the EMG ratios presents applicable in trained populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posture can be defined as the overall position and spatial orientation of the human body and its members relative to each other. The study of posture can be applied either static, with the subject standing still. Objectives: to identify and quantify the static posture alignment of individuals who were either symptomatic or asymptomatic for cervical pain. Methods: A cross-sectional study was carried out on subjects with cervical pain and individuals with no complaints of pain. The procedure consists in placing markers on specific points. Several views, following the protocol of the Posture Assessment software, regarding the measurement of angles (in degrees) and differences in lower leg lengths (in centimeters). Angles were analyzed through the comparison of averages between the groups using test t Student, (alpha=5%). Results: There enrolled 27 subjects. There were differences in horizontal alignment of head (3.37x1.33), acromia (2.60x1.18), iliac spines (2.91x0.67), vertical alignment of head (25.70x18.26) and in length of lower limbs (1.36x0.75) in respect to cervical and asymptomatic subjects. Conclusions: Was possible identify and quantify the static posture alignment of individuals with and with no cervical pain. The data obtained suggest the presence of asymmetry in all the symptomatic individuals studied. The data obtained suggest the presence of overall asymmetry in all the symptomatic individuals studied. © 2009 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to measure the thickness of the hybrid layer (HLT), length of resin tags (RTL) and bond strength (BS) in the same teeth, using a self-etching adhesive system Adper Prompt L Pop to intact dentin and to analyze the correlation between HLTand RTL and their BS. Ten human molars were used for the restorative procedures and each restored tooth was sectioned in mesio-distal direction. One section was submitted to light microscopy analysis of HLT and RTL (400x). Another section was prepared and submitted to the microtensile bond test (0.5 mm/min). The fractured surfaces were analyzed using scanning electron microscopy to determine the failure pattern. Correlation between HLT and RTL with the BS data was analyzed by linear regression. The mean values of HLT, RTL and BS were 3.36 microm, 12.97 microm and 14.10 MPa, respectively. No significant relationship between BS and HLT (R2= 0.011, p>0.05) and between BS and RTL (R2= 0.038) was observed. The results suggested that there was no significant correlation between the HLT and RTL with the BS of the self-etching adhesive to dentin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of soil drill rod length on the N value in the SPT-T test has been studied extensively by Mello (1971), Schmertmann & Palacios (1979), Odebrecht et al. (2002) and Cavalcante (2002). This paper presents an analysis of the Standard Penetration Test supplemented with torque measurement (SPT-T). A theoretical study of the resistance of the rod material to torsion and bending indicated that the shear stress caused by the rod self-weight represents less than 1% of that caused by the torsional moment. An experimental study with electric torquemeters attached to a horizontal rod system, as well as two field tests in the vertical direction, were also carried out to compare and substantiate the results. The purpose of these tests was to analyze changes along the length of the rod in response to successive increments at 1-meter intervals. Torque measurements were taken at each increment of the length to ascertain the accuracy of the theoretical data. The difference between the applied torque and the measured torque at the end of rod system was lower than the minimum scale of mechanical torquemeters used in practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the tissue composition and carcass muscularity of 32 legs of Ile de France lambs fed with diets containing sunflower seeds and vitamin E, with mean body weight of 15 kg, lodged in individual pens at 15 kg and slaughtered at 32 kg of body weight. The treatments influenced (P<0,05) leg weight, femur length and muscle: bone ratio, being the highest values (2,13 kg, 16,19 cm and 7,38, respectively) in lambs that received diet without sunflower seeds and vitamin E. The other variables were not affected (P>0,05) by the treatments. The interaction of the sunflower and vitamin E was positive for bone total weights and intramuscular fat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the use of a two-step total etch and rinse adhesive, the correlation between the hyybrid layer thickness (HL) and bond strength (BS), and between resin tag length (RT) and bond strength in the same teeth, and also to evaluate the fracture patterns of the tested specimens. Ten human molars were used for the restorative procedure and then sectioned in two halves (mesio-distally). The materials used were Adper Single Bond 2, 3M ESPE, Ultra etch gel, Ultradent and Filtek Z250, 3M ESPE. One half were utilized to measure the HL thickness and RT length through light microscopy analysis (400x), and the other half was subject to a microtensile test to measure the BS. The fractured surfaces were analyzed by scanning electron microscopy and fracture patterns classified. The Pearson correlation test was applied (p = 0.05). The results of the analyses of each specimen then were correlated: mean HL thickness = 4.39 (0.48) microm, mean length of RT = 9.94 (1.69) microm, mean BS = 23.98 (10.24) MPa. A statistically significant correlation between HL thickness and bond strength was found (r = 0.93). The two step etch and rinse adhesive system, showed a strong correlation between HL thickness and bond strength. The most common fractures were adhesive, followed by cohesive in resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the correlation between the hybrid layer thickness/resin tag length and the microtensile bond strength of conventional two-step adhesive system, when applied to healthy dentinal tissue. After performing the restorative adhesive procedures and tooth extractions, ten specimens were sectioned in the mesiodistal direction. One section was used for microscopic analysis of the resin tag lengths and the hybrid layer thickness, while the other was used for the microtensile bond strength test (0.5 mm/min). The fractured surface was classified according to the fracture pattern, under a stereoscopic microscope at 40x magnification. Data obtained were submitted to analysis using one-way ANOVA and Pearson's Correlation test (alpha=0.05). The means corresponding to the hybrid layer thickness, resin tag lengths and the microtensile test were 2.68 microm, 6.43 microm and 16.23 MPa, respectively. There was no correlation between the means of the values obtained for the microtensile test, and those presented by the hybrid layer (r2=0.40, p>0.05) and resin tags (r2=0.21, p>0.05). The microtensile bond strength of the conventional two-step adhesive system Adper Single Bond 2 did not depend on the thickness of the hybrid layer and length of resin tags.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral connection is necessary, including Active Power Filter applications. This topology presents advantages regarding the VSI DC link and capacitance, which make it useful for high power devices. Theory, implementation and simulations are also discussed in this paper. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of the coefficient of thermal expansion on the spin-liquid candidate κ-(BEDT-TTF) 2Cu 2(CN) 3 have revealed distinct and strongly anisotropic lattice effects around 6 K - a possible spin liquid instability. In order to study the effects of a magnetic field on the low-temperature spin-liquid state, dilatometric measurements have been conducted both as a function of temperature at B = const. and as a function of field at T = const. While the 6 K anomaly is found to be insensitive to magnetic fields B ≤ 10 T, the maximum field applied, surprisingly strong B -induced effects are observed for magnetic fields applied along the in-plane b-axis. Above a threshold field of 0.5 T < B c ≤ 1 T, a jump-like anomaly is observed in the b-axis lattice parameter. This anomaly, which is located at 8.7 K at B = 1 T, grows in size and shifts to lower temperatures with increasing the magnetic field. Although the anomaly bears resemblance to a first-order phase transition, the lack of hysteresis suggests otherwise. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This experiment evaluated the growth of breast and leg muscle fibers of domestic fowl raised in two enclosure sizes (SE: Small Enclosure, 1.125 m2/10 birds; LE: Large Enclosure, 5.25 m2/10 birds). In breast muscles, the number of fibers per area decreased over time and higher values were observed in broilers housed in SE compared to LE. The fiber size increased with age and was greater in LE than SE at 56 days of age, suggesting greater hypertrophic growth of fibers in breast muscle for broilers maintained in LE. In leg muscles, the muscle cross-sectional area was greater for broilers raised in LE than SE at 56 days of age and decreased from 42 to 56 days of age in broilers raised in SE, suggesting leg muscle atrophy in these birds. The Fast Glycolytic (FG), Fast Oxidative-Glycolytic (FOG) and Slow Oxidative (SO) fibers grew until 42 days of age in both enclosure sizes. The area of FOG fibers was greater in broilers raised in LE than those in SE at 28 and 56 days of age; in LE-raised broilers, the SO area was greater at 28, 42 and 56 days of age, suggesting that the muscles of broilers housed in LE are more oxidative. The BW gain was greater for broilers raised in LE than SE, whereas BW, feed intake and feed conversion were not influenced by enclosure size. Thus, the enclosure space affected hypertrophic growth and metabolic characteristics of breast and leg muscle fibers. © Asian Network for Scientific Information, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-pressure compensating drip hose is widely used for irrigation of vegetables and orchards. One limitation is that the lateral line length must be short to maintain uniformity due to head loss and slope. Any procedure to increase the length is appropriate because it represents low initial cost of the irrigation system. The hypothesis of this research is that it is possible to increase the lateral line length combining two points: using a larger spacing between emitters at the beginning of the lateral line and a smaller one after a certain distance; and allowing a higher pressure variation along the lateral line under an acceptable value of distribution uniformity. To evaluate this hypothesis, a nonlinear programming model (NLP) was developed. The input data are: diameter, roughness coefficient, pressure variation, emitter operational pressure, relationship between emitter discharge and pressure. The output data are: line length, discharge and length of the each section with different spacing between drippers, total discharge in the lateral line, multiple outlet adjustment coefficient, head losses, localized head loss, pressure variation, number of emitters, spacing between emitters, discharge in each emitter, and discharge per linear meter. The mathematical model developed was compared with the lateral line length obtained with the algebraic solution generated by the Darcy-Weisbach equation. The NLP model showed the best results since it generated the greater gain in the lateral line length, maintaining the uniformity and the flow variation under acceptable standards. It had also the lower flow variation, so its adoption is feasible and recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the correlation between the hybrid layer thickness, resin tag length and resin bond strength of a self-etching adhesive system to sound dentin tissue in vivo. After performing restorative procedures and tooth extractions, ten specimens were sectioned in a mesiodistal direction. One dental section was used for light microscope analysis, in which both the resin tag length and hybrid layer thickness were measured, while the other section was analyzed using a microtensile test (0.5 mm/min). The fractured surface of the latter section was characterized using a stereoscopic magnifying glass (40x magnifcation). The results were subject to statistical analysis using the Pearson Correlation Test (a = 0.05). The hybrid layer thickness, resin tag length and resin bond strength mean values were 2.19 microm (0.34), 4.34 microm (0.28) and 9.73 MPa (5,55), respectively. In addition, correlation tests between the resin tag length and the resin bond strength (r=0.014) and also between the hybrid layer thickness and bond strength (r=0.43), showed no statistically significant correlation. The microtensile bond strength of Adper Prompt L Pop self-etching adhesive system does not depend on hybrid layer thickness or resin tag length.