255 resultados para LED light calibration system
Resumo:
Purpose: To evaluate clinically and microscopically the human pulp response when directly capped with an adhesive system or calcium hydroxide over short (9-12 days) and long (53-204 days) experimental periods. Materials and Methods: Fifty-one sound human premolars scheduled for orthodontic extraction, had their pulp horns gently exposed with a diamond point. Debris in the pulp wound was washed out with a sterile saline solution. The pulps were then capped with either an adhesive system (Scotchbond Multi-Purpose Plus) or calcium hydroxide. All teeth were subsequently restored with resin-based composite (Z-100) according to the manufacturer's instructions. After the experimental periods, the teeth were extracted and processed for light microscopic examination. Results: Short-term: the pulp tissue capped with SBMP-P exhibited dilated and congested blood vessels associated with a mo;derate inflammatory response and blanching of pulp cell nuclei. Long-term: no evidence of healing and bridge formation was observed. A persistent mild inflammatory pulp response was present. Micro-abscesses were detected in three cases associated with bacterial infiltration. Calcium hydroxide stimulated early pulp repair and dentin bridging which extended into the longest period.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study evaluated the influence of light-curing units (LCUs) on Knoop microhardness (KHN) of different composite resins formulations. Four LCUs, one Quartz-Tungsten-Halogen (QTH) for 20 s, one Argon-Ion-Laser (AL) for 10 s, one Plasma-Arc-Curing (PAC) for 9 s, and one Light-Emitting-Diode (LED) for 20 s, and three composite resins, nanofill and easy cure (Filtek (TM) Supreme), microhybrid and medium cure (Herculite XRV), and microfill and difficult cure (Heliomolar) were used. Discs (4 x 2 mm(2)) of each composite resin were divided in 12 Groups and KHN was measured at the top (T) and bottom (B) surfaces. Data were analyzed using two-way ANOVA and Tukey's test (p < 0.05). Top presented significantly higher KHN than bottom surface for all composite resins and LCUs tested. Statistical significant differences were observed among the LCUs. At the bottom surface QTH and LED presented higher KHN than PAC and LA. However, at the top surface PAC and LA presented similar results than QTH for nanofill and microhybrid composite resins. Different LCUs play an important effect on Knoop microhardness and the composite resin formulations were significant factor on the photosensitivity.
Resumo:
The purpose of this study was to evaluate the influence of different light sources for in-office bleaching on surface microhardness of human enamel. One hundred and five blocks of third molars were distributed among seven groups. The facial enamel surface of each block was polished and baseline Knoop microhardness of enamel was assessed with a load of 25 g for 5 s. Subsequently, the enamel was treated with 35% hydrogen peroxide bleaching agent and photo-activated with halogen light (group A) during 38 s, LED (group B) during 360 s, and high intensity diode laser (group C) during 4 s. The groups D (38 s), E (360 s), and F (4 s) were treated with the bleaching agent without photo-activated. The control (group G) was only kept in saliva without any treatment. Microhardness was reassessed after 1 day of the bleaching treatment, and after 7 and 21 days storage in artificial saliva. The mean percentage and standard deviation of microhardness in Knoop Hardness Number were: A 97.8 +/- 13.1 KHN; B 95.5 +/- 12.7 KHN; C 84.2 +/- 13.6 KHN; D 128.6 +/- 20.5 KHN; E 133.9 +/- 14.2 KHN; F 123.9 +/- 14.2 KHN; G 129.8 +/- 18.8 KHN. Statistical analysis (p < 0.05; Tukey test) showed that microhardness percentage values were significantly lower in the groups irradiated with light when compared with the non-irradiated groups. Furthermore, the non-irradiated groups showed that saliva was able to enhance the microhardness during the measurement times. The enamel microhardness was decreased when light sources were used during the bleaching process and the artificial saliva was able to increase microhardness when no light was used.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to determine the effect of two light-curing units (QTH and LED) on microleakage of Class II composite resin restorations with dentin cavosurface margins. Twenty extracted mandibular first premolars, free of caries and fractures were prepared two vertical slot cavities in the occluso-mesial and -destal surfaces (2 mm buccal-lingually, 2 mm proximal-axially and cervical limit in enamel) and divided into 4 equal groups (n = 8): GI and GII: packable posterior composite light-activated with LED and QTH, respectively; GIII and GIV: micro-hybrid composite resin light-activated with LED and QTH, respectively. The composite resins were applied following the manufacturer's instructions. After 24 h of water storage specimens were subjected to thermocycling for a total of 500 cycles at 5 and 55A degrees C and the teeth were then sealed with impermeable material. Teeth were immersed in 0.5% Basic fuchsin during 24 h at room temperature, and zero to three levels of penetration score were attributed. The Mann-Whitney and Kruskal-Wallis tests showed significant statistically similar (P > 0.05) from GI to GII and GIII to GIV, which the GII (2.750) had the highest mean scores and the GIII and GIV (0.875) had lowest mean scores. The use of different light-curing units has no influence on marginal integrity of Class II composite resin restorations and the proprieties of composite resins are important to reduce the microleakage.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Nowadays the real contribution of light on the acceleration of the chemical reaction for the dental bleaching is under incredulity, mostly because the real mechanisms of its contribution still are obscure. Objectives: Determine the influence of pigment of three colored bleaching gels in the light distribution and absorption in the teeth, to accomplish that, we have used in this experiment bovine teeth and three colored bleaching gels. It is well Known that the dark molecules absorb light and increase the local temperature upraising the bleaching rate, these molecules are located in the interface between the enamel and dentin. Methods: This study was realized using an argon laser with 455nm with 150mW of intensity and a LED with the same characteristics, three colored gels (green, blue and red) and to realize the capture of the digital images it was used a CCD camera connected to a PC. The images were processed in a mathematical environment (MATHLAB, R12 (R)). Results: The obtained results show that the color of the bleaching gel influences significantly the absorption of light in the specific sites of the teeth. Conclusions: This poor absorption can be one of the major factors involved with the incredulity of the light contribution on the process that can be observed in the literature nowadays.
Resumo:
The aim of this study was to determine the influence of three light-curing units, storage times and colors of the dental composite resin on the fluorescence. The specimens (diameter 10.0 +/- 0.1 mm, thickness 1.0 +/- 0.1 mm) were made using a stainless steel mold. The mold was filled with the microhybrid composite resin and a polyethylene film covered each side of the mold. After this, a glass slide was placed on the top of the mold. To standardize the top surface of the specimens a circular weight (1 kg) with an orifice to pass the light tip of the LCU was placed on the top surface and photo-activated during 40 s. Five specimens were made for each group. The groups were divided into 9 groups following the LCUs (one QTH and two LEDs), storage times (immediately after curing, 24 hours, 7 and 30 days) and colors (shades: A(2)E, A(2)D, and TC) of the composite resin. After photo-activation, the specimens were storage in artificial saliva during the storage times proposed to each group at 37 C and 100% humidity. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed no significant difference between storage times (immediately, 24 hours and 30 days) (P > 0.05). The means of fluorescence had difference significant to color and light-curing unit used to all period of storage (P < 0.05). The colors had difference significant between them (shades: A2D < A2E < TC) (P < 0.05). The Ultraled (LED) and Ultralux (QTH) when used the TC shade showed higher than Radii (LED), however to A2E shade and A2D shade any difference were found (P > 0.05).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Individuals of two populations of the fish Characidium cf. fasciatum were cytogenetically studied and showed a basic diploid number of 50 chromosomes. Some fishes were found to have 51 to 54 chromosomes due to the presence of one to four small subtelocentric/acrocentric supernumerary chromosomes. When analyzed by conventional Giemsa staining, male and female specimens of C. cf. fasciatum from the Quinta stream and Pardo River presented the same basic karyotypic macro- and microstructure, consisting of 32 metacentric and 18 submetacentric chromosomes.Ag-NORs were terminally located on the long arms of two submetacentric chromosome pairs. Constitutive heterochromatin was identified by C-banding as small pericentromeric blocks in the majority of the chromosomes, and B-chromosomes were found to be heterochromatic. The occurrence of one totally heterochromatic submetacentric chromosome restricted to females and considered as an unusual feature in fish karyotypes led to the identification of a ZZ/ZW sex-chromosome system. The implications of chromosomic differentiation observed in the genus Characidium are discussed.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Female reproductive system of the decapitating fly Pseudacteon wasmanni Schmitz (Diptera : Phoridae)
Resumo:
Pseudacteon wasmanni is a South American decapitating fly that parasitizes workers of Solenopsis fire ants. We used light microscopy (historesin serial-sectioning stained with Haematoxylin/Eosin) and scanning electron microscopy to show and analyze internal and whole external views of the female reproductive system. All specimens analyzed (n = 9) by light microscopy showed post-vitellogenic oocytes inside the ovaries. The lack of typical follicles (oocyte-nurse cell complexes) in all specimens suggests that oogenesis occurs during the pupal stage. The total number of eggs found ranged from 31 to 280 (X = 142 +/- 73, SD). The egg has a slugform or torpedo shape (about 130 by 20 mum) with a pointed apex at the posterior pole as defined by the fly; the micropyle appears to be in a depression or invagination at the anterior pole. An acute hypodermic-like ovipositor is evaginated from the hard sclerotized external genitalia during egg laying. The existence of a muscular bulb associated with the end of the common oviduct suggests that the egg is injected into the ant's body by a strong contraction of the bulb which probably is stimulated by bending of several ventral sensilla. During contraction, the abdomen extends out along a large fold between the sixth and seventh tergites in such a way that the sclerotized genitalia is rotated ventrally into a slightly anterior orientation in preparation for oviposition. (C) 2003 Elsevier B.V. Ltd. All rights reserved.