215 resultados para In vitro digestibility of organic matter (IVDOM)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). Materials and Methods: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group I Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. Results: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p < 0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p > 0.05). Conclusion: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened oot canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The major globulin fraction from lentil seeds was investigated with respect td in vitro hydrolysis by trypsin and chymotrypsin. Globulin was isolated by a NaCl-ascorbate extraction procedure and purified by DEAE-cellulose chromatography and gelfiltration chromatography on Sepharose CL-6B. The purity and identification of the protein were performed by PAGE. The native globulin, with a molecular weight of 375 kD, was resolved by SDS-PAGE into twelve polypeptides with molecular weights ranging from 61 to 14.5 kD. Native and heated globulin GI was hydrolyzed with trypsin and chymotrypsin. SDS-PAGE indicated that native globulin was more resistant to digestion than heated protein. Amino acid analysis of the major globulin revealed that glutamic acid was present in the largest concentration, followed by aspartic acid, arginine and leucine. As is also the case for other legumin-like globulins, lentil GI was deficient in sulfur-containing amino acids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of intrapulpal pressure and dentin depth on bond strengths of an etch-and-rinse and a self-etching bonding agent to dentin in vitro and in vivo. Twenty-four pairs of premolars were randomly divided into four groups (n = 6) according to the dentin bonding agent, Single Bond and Clearfil SE Bond, and intrapulpal pressure, null or positive. Each tooth of the pair was further designated to be treated in vivo or in vitro. The intrapulpal pressure was controlled in vivo by the delivery of local anesthetics containing or not a vasoconstrictor, while in vitro, it was achieved by keeping the teeth under hydrostatic pressure. Class I cavities were prepared and the dentin bonding agents were applied followed by incremental resin restoration. For the teeth treated in vitro, the same restorative procedures were performed after a 6 month-storage period. Beams with I mm 2 cross-sectional area were prepared and, microtensile tested. Clearfil SE Bond was not influenced by any of the variables of the study, while bond strengths produced in vitro were significatly higher for Single Bond. Overall, lower bond strengths were produced in deep dentin, which reached statistical significance when Single Bond was applied under physiological or simulated intrapulpal pressure. In conclusion, in vitro bonding may overestimate the immediate adhesive performance of more technique-sensitive dentin bonding systems. The impact of intrapulpal pressure on bond strength seems to be more adhesive dependent than dentin morphological characteristics related to depth. (C) 2007 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was aimed at investigating the in vitro biocompatibility of a novel membrane of the composite poly(vinylidene-trifluoroethylene)/barium titanate (P(VDF-TrFE)/BT). Osteoblastic cells were obtained from human alveolar bone fragments and cultured under standard osteogenic condition until subconfluence. First passaged cells were cultured on P(VDF-TrFE)/BT and expanded polytetrafluoroethylene (e-PTFE - control) membranes in 24-well plates. Cell adhesion and spreading were evaluated at 30 min, and 4 and 24 h. For proliferation assay, cells were cultured for 1, 7, and 10 days. Cell viability was detected by trypan blue at 7 and 10 days. Total protein content and alkaline phosphatase (ALP) activity were measured at 7, 14, and 21 days. Cultures were stained with Alizarin red at 21 days, for detection of mineralized matrix. Data were compared by ANOVA and Student t test. Cell attachment (p = 0.001), cell number (p = 0.001), and ALP activity (p = 0.0001) were greater on P(VDF-TrFE)/BT. Additionally, doubling time was greater on P(VDF-TrFE)/BT (p = 0.03), indicating a decreased proliferation rate. Bone-like nodule formation took place only on P(VDF-TrFE)/BT. The present results showed that both membranes are biocompatible. However, P(VDF-TrFE)/BT presented a better in vitro biocompatibility and allowed bone-like nodule formation. Therefore, P(VDF-TrFE)/BT could be an alternative membrane to be used in guided tissue regeneration. (c) 2006 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vitro inhibition of the of spores germination of Alternaria solani by iprodione, chlorothalonil, and anilazine at different dosages was studied. The highest concentration of active ingredient studied for each fungicide was equivalent to that recommended for the control of the early blight, under field conditions: 0.75; 1.80 and 1.44 g, respectively, of iprodione, chlorothalonil and anilazine per litre of water. A series of two-fold diluitions of each original concentration was studied in additional nine experiments. Eah of the three fungicides showed total in vitro spore inhibition at the highest rate, at six hours of incubation. At nine hours, only analazine mantained its full inhibition activity. The inhibition activity of iprodione decreased suddenly after 1/2 dilution, so that at the 1/8 dilution a total loss of inhibitory activity was observed. Chlorothalonil showed a progressive and slighter decrease of its activity as the dilution rate increased.Analizine showed a high inhibitory activity at higher dilutions, without any loss up to 1/128 dilution. Even at 1/512 dilution, its activity was so high that only 20% of spore germination was observed at six or nine hours of incubation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Oropouche, Caraparu, Guama, Guaroa and Tacaiuma are ssRNA viruses that belong to the genus Orthobunyavirus and have been associated with human febrile illnesses and/or encephalitis. In this study, we evaluated the antiviral action of mycophenolic acid (MPA) on these orthobunyaviruses to achieve a therapeutic agent to treat the diseases caused by these viruses. Methods: the in vitro antiviral evaluation to MPA was done by using plaque assay at different periods of treatment. Results: Results showed that MPA at a concentration of 10 mu g/ml has significant antiviral activity on Tacaiuma virus when treatment was initiated either 24 h before or 2 h after viral infection. Moreover, MPA has an inhibitory effect on Guama virus replication, but only when treatment was initiated before cell infection. Addition of guanosine in the culture reverted the inhibitory effect of MPA on Tacaiuma and Guama viruses, suggesting that the antiviral activity of this substance was via depletion of the intracellular guanosine pool. Conclusion: Our results suggest that MPA would not be a good therapeutic agent to treat the diseases caused by Oropouche, Caraparu, Guama, Guaroa, and Tacaiuma viruses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effectiveness of acidic low-fluoride dentifrices compared to conventional neutral dentifrices. Enamel blocks were submitted to pH cycling and treatment with slurries of dentifrices containing 0, 275, 412, 550 and 1,100 mu g F/g (pH 4.5 or 7.0), and also a commercial dentifrice (1,100 mu g F/g) and a commercial children's dentifrice (500 mu g F/ g). Variations in surface microhardness and in the mineral content in enamel after pH cycling were calculated. Enamel blocks treated with acidic dentifrices exhibited less mineral loss compared to neutral dentifrices (ANOVA; p < 0.05). The acidic dentifrices with 412 and 550 mu g F/g had the same effectiveness as the neutral 1,100-mu g F/g dentifrice and commercial 1,100-mu g F/g dentifrice. Copyright (c) 2007 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shear bond strength of brackets bonded with different restorative systems and compare it with that afforded by an established orthodontic bonding system. Seventy human bicuspids were used, divided into five different groups with 14 teeth each. Whereas a specific orthodontic bonding resin (Transbond (TM) XT) was used in the control group, the restorative systems Charisma, Tetric Ceram, TPH Spectrum and Z100 were used in the other four groups. Seven days after bonding the brackets to the samples, shear forces were applied under pressure in a universal testing machine. The data collected was evaluated using the ANOVA test and, when a difference was identified, the Tukey test was applied. A 5% level of significance was adopted. The mean results of the shear bond strength tests were as follows: Group 1 (Charisma), 14.98 MPa; Group 2 (Tetric Ceram), 15.16 MPa; Group 3 (TPH), 17.70 MPa; Group 4 (Z100), 13.91 MPa; and Group 5 or control group (Transbond (TM) XT), 17.15 MPa. No statistically significant difference was found among the groups. It was concluded that all tested resins have sufficient bond strength to be recommended for bonding orthodontic brackets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber, and bellows type. The evaluation was performed by in vitro tests of parameters such as heat transfer, pressure drop, and hemolysis tendency. The result has shown that all four systems tested were able to achieve the heat performance, and to offer low resistance to flow, and safety, as well as have low tendency to hemolysis. However, we can emphasize that the bellows type heat exchanger has a significant difference with regard to the other three types.