125 resultados para Imagem digital : Classificação
Resumo:
The comet assay is a method of DNA damage analysis widely used to quantify oxidative damage, crosslinks of DNA, apoptosis and genotoxicity of chemicals substances as chemical, pharmaceuticals, agrochemicals products, among others. This technique is suitable to detect DNA strand breaks, alkali-labile sites and incomplete excision repair sites and is based on the migration of DNA fragments by microeletroforesis, DNA migrates for the anode forming a “tail”, and the formed image has the appearance of a comet. The slides can be stained with fluorescence or silver, having differences in the microscopy type used for the analysis and the possibility of storage of the slides, moreover, the first one is a stained-method with more difficulties of accomplishment. The image analysis can be performed by a visual way, however, there is a disadvantage as the subjectivity on the results, that can be minimized by an automated method of digital analysis. This process was studied in this report with the aim to perceive the validation of the digital analysis turning it a quantitative method with larger reproductibility, minimizing the variability and imprecision due to the subjective analysis. For this validation we selected 50 comets photographed in a standardized way and printed, afterwards, pictures were submitted to three experienced appraisers, who quantified them manually. Later, the images were processed by free software ImageJ 1.38x, printed and quantified manually by the same appraisers. The intraclass correlation was higher to comet measures after image processing. Following, an algorithm of automated digital analysis from the measures of the comet was developed; the values obtained were compared with those 12 estimated manually after the processing resulting high correlation among the measures. The use of image analysis systems increases ...(Complete abstract click electronic access below)
Resumo:
The objective of this paper is to discuss the construction of the image of São Paulo state public schools teachers in the public sphere, by the media and the trade union press, and see how that image is formed in both of them, without making any comparisons, from the covering of 2010 strikes by newspapers Folha de S. Paulo and Jornal da Apeoesp. This paper uses as theoretical basis the study of Media Hegemony, the concept of Radical Media and Public Sphere, as well as the relationship between them and social movements. It also considers the observation of the history and characteristics of trade union press and the Standards of Manipulation by the Press, proposed by Perseu Abramo. The chosen method was the identification, selection and organization of stories about education published by Folha de S. Paulo during the period; the application of Abramo’s proposed manipulation standards on the stories about the strike; research, selection and observation of print publications (Jornal da Apeoesp and newsletters Apeoesp Urgente) about the strike, published by Apeoesp during the same period
Resumo:
The Caudal Cervical Spondylomyelopathy, also known as “Wobbler syndrome” is a neurological disorder that affects mainly breeds of large and giant size, especially Doberman pinsher and Great danes. Its aetiology is multifactorial and leads to a narrowing of the spinal canal by morphological and positional caudal cervical vertebrae (C5, C6 and C7), causing compression of the spinal cord and nerve roots. The clinical signs presented by the affected animals are progressive ataxia of hindlimbs and, later, the forelimbs, sometimes progressing to tetraparesis. Neck pain may be present. The diagnosis is made through the association of clinical signs and diagnostic imaging such as radiography, myelography, computed tomography and magnetic resonance imaging. According to the classification of the lesion obtained by imaging examinations, the conservative or surgical treatment is established and the prognosis is variable in accordance with the degree of affection of the spinal cord
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
The biometric characteristics have been used increasingly as a way to identify an individual, mainly for security reasons. Among them, the fingerprint is the most used biometric characteristic around the world, because it is relatively simple and very efficient. In this scene, there was a significant increase in the size of databases containing information on fingerprints, necessary to perform the recognition of a person. The task of classifying them beforehand has become extremely important as it reduces dramatically the size of the problem during a search, because it is not necessary to go through the whole database. Considering its importance, in the last thirty years, many techniques have been developed to try to increase the efficiency of the classification process. This project followed the rules-based approach and the Software Development Kit (SDK) VeriFinger 6.1 was used to assist in the detection of cores and deltas. Additionally, the classification was also implemented by means of directional map and the Poincar´e index. To make the experiments, the number four database from the National Institute of Standards and Technology (NIST) was used, which is a standard in this area
Resumo:
This monograph has as objectives introduce digital terrestrial television, describing the process of installation of this in Spain, their technical qualities and possibilities of change and innovation that this creates. The exposure of the different chapters of this monograph has a objective presenting and discussing what are the characteristics of this new technology, your birth, what is its importance in communication and how this is inserted inside the Spanish reality. The introduction of digital terrestrial television in Spain is cited as an example of a pioneer in the development and installation of this new technology, but also appears as a nation that has come a way with some economic failures, reaching one of the largest cases of delayed installation of digital television in Western Europe. Making use of the European system for digital terrestrial television (DVB-T - Digital Video Broadcasting) it was possible some advances as the quality of communication and strengthening national public television system, but many vices of analog system were transferred this new system, as the concentration of channels to a foreign group and interactivity opportunities were wasted. Digital terrestrial television can provides better picture quality and sound, possibility of interactivity, mobility, hypermedia and multiprogramming, while the latter tool may lead to the democratization of media, opening it to other social agents. Going much further than just a technological advancement, digital television is strongly connected with the politics and the economy of the nation in which it operates
Resumo:
In this project the Pattern Recognition Problem is approached with the Support Vector Machines (SVM) technique, a binary method of classification that provides the best solution separating the data in the better way with a hiperplan and an extension of the input space dimension, as a Machine Learning solution. The system aims to classify two classes of pixels chosen by the user in the interface in the interest selection phase and in the background selection phase, generating all the data to be used in the LibSVM library, a library that implements the SVM, illustrating the library operation in a casual way. The data provided by the interface is organized in three types, RGB (Red, Green and Blue color system), texture (calculated) or RGB + texture. At last the project showed successful results, where the classification of the image pixels was showed as been from one of the two classes, from the interest selection area or from the background selection area. The simplest user view of results classification is the RGB type of data arrange, because it’s the most concrete way of data acquisition
Resumo:
Paediatric diagnostic radiology can be considered as a separate specialty and with distinct characteristics of the radiology applied in adult patients. This in reason of the variability in the anatomical structures size and bigger sensitivity of tissues. The literature present in its majority methodologies for segmentation and tissue classification in adult patients, and works on tissue quantification are rare. This work had for objective the development of a biological tissue classifier and quantifier algorithm, from histograms, and that converts the quantified average thickness of these tissues for its respective simulator materials. The results will be used in the optimization process of paediatrics images, in future works, since these patients are frequently over exposed to the radiation in the repeated attempts of if getting considered good quality radiographic images. The developed algorithm was capable to read and store the name of all the archives, in the operational system, to filter artifacs, to count and quantify each biological tissues from the histogram of the examination, to obtain the biological tissues average thicknesses and to convert this value into its respective simulator material. The results show that it is possible to distinguish bone, soft, fat and pulmonary tissues from histograms of tomographic examinations of thorax. The quantification of the constituent materials of anthropomorphic phantom made by the algorithm, compared with the data of literature shows that the biggest difference was of 21,6% for bone. However, the literature shows that variations of up to 30% in bone thickness do not influence of significant form in the radiographic image quality. The average thicknesses of biological tissues, quantified for paediatrics patients, show that one phantom can simulate patients with distinct DAP ranges, since variations... (Complete abstract click electronic access below)
Resumo:
A virtual studio system can use technologies as augmented reality and digital matting to decrease production costs at the same time it provides the same resources of a conventional studio. With this, it’s possible for the current studios, with low cost and using conventional devices, to create productions with greater image quality and effects. Some difficulties are recurrent in virtual studio applications that use augmented reality and digital matting. The virtual objects registration in augmented reality techniques suffer from problems caused by optical distortions in the camera, errors in the marker tracking system, lack of calibration on the equipments or on the environment (lighting, for example), or even by delays in the virtual objects display. On the other hand, the digital matting’s main problem is the real-time execution to preview the scene, which must have optimized processing speed at the same time while maintain the best image quality possible. Taking the given context into consideration, this work aims to give continuity to a virtual studio system called ARStudio, by enhancing digital matting, virtual objects registration and introducing a segmentation based on depth map, yet adding better control over functionalities previously implemented
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Nuclear Medicine is a medical modality of therapy and diagnostic imaging using unsealed radioactive sources for its purposes. This routine activity promotes the transit of radioactive sources for the area of installation, beyond the transit of patients injected with radioisotope, which also contribute to raising the radiometric level of environment. As a consequence, it has exposured workers and public individuals to the ionizing radiation. There are protective mechanisms of radiation exposure, personal protective equipments, and measurement planes established in standard measurement at certain points of the environment in order to identify any increase in radiometric levels and \ or contamination, but do not cover the entire space occupied by workers and patients. To accomplish with the individual dose limits established by the National Commission of Nuclear Energy, it is interesting if there is an individualized classification for each Nuclear Medicine service. This work aimed to promote an analysis of the radiometric level distribution across the extent of the Technical Nuclear Medicine Sector of Hospital of the Botucatu Medical School, and produce a spatial map to identify locations with higher exposure rate to the ionizing radiation, can be used as a risk map to assist the Occupationally Exposed Individuals (IOE). To perform the radiometric levels checking it was used a digital Geiger-Muller detector available in the sector, due to its practicality compared to other detectors. Measurements were carried out at four different times for all days of the week, at points strategically established to cover all the installation
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC
Resumo:
Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC