112 resultados para Geographic location


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The computational program called GIS_EM (Geographic Information System for Environmental Monitoring), a software devised to manage geographic information for monitoring soil, surface, and ground water, developed for use in the Health, Safety, and Environment Division of Paulinia Refinery is presented. This program enables registering and management of alphanumeric information pertaining to specific themes such as drilling performed for sample collection and for installation of monitoring wells, geophysical and other tests, results of chemical analyses of soil, surface, and groundwater, as well as reference values providing orientation for soil and water quality, such as EPA, Dutch List, etc. Management of such themes is performed by means of alphanumeric search tools, with specific filters and, in the case of spatial search, through the selection of spatial elements (themes) in map view. Documents existing in digital form, such as reports, photos, maps, may be registered and managed in the network environment. As the system centralizes information generated upon environmental investigations, it expedites access to and search of documents produced and stored in the network environment, minimizing search time and the need to file printed documents. This is an abstract of a paper presented at the AIChE Annual Meeting and Fall Showcase (Cincinnati, OH 10/30/2005-11/4/2005).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a dedicated algorithm for lation of single line-to-ground faults in distribution systems. The proposed algorithm uses voltage and current phasors measured at the substation level, voltage magnitudes measured at some buses of the feeder, a database containing electrical, operational and topological parameters of the distribution networks, and fault simulation. Voltage measurements can be obtained using power quality devices already installed on the feeders or using voltage measurement devices dedicated for fault location. Using the proposed algorithm, likely faulted points that are located on feeder laterals geographically far from the actual faulted point are excluded from the results. Assessment of the algorithm efficiency was carried out using a 238 buses real-life distribution feeder. The results show that the proposed algorithm is robust for performing fast and efficient fault location for sustained single line-to-ground faults requiring less than 5% of the feeder buses to be covered by voltage measurement devices. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix metalloproteinases (MMPs) and their tissue inhibitors (TIMPs) play a major role in extracellular matrix component degradation in several normal and abnormal tissue situations; they are also found in human seminal plasma. MMPs have been found in rat prostate secretions and are nearly lobe specific in expression pattern. The aim of this study was to evaluate whether TIMP-2, like other semen components, is expressed differently from different rat prostatic lobes. Immunohistochemical staining was performed in both young and adult rat ventral (VP), lateral (LP), dorsal (DP), and anterior (AP) prostatic lobes and confirmed by western blotting. TIMP-2 expression was found in the epithelial cells in the following sequence: LP > AP > DP > VP, in both young and adult rats. In this study, 100% of adult LP presented histological signs of prostatitis, where TIMP-2 immunostaining was positive in normal epithelium even with intraluminal neutrophils, but was reduced or absent in the epithelium with intraepithelial leukocytes or with periductal stroma disorganization associated with mononuclear cell infiltration. However, TIMP-2 expression in LP was not induced by prostatitis, since younger rat LPs were also strongly TIMP-2 positive. The distal and intermediate VP regions were TIMP-2 negative, but the proximal regions were strongly stained. Western blotting results confirmed the high TIMP-2 expression in the LP lobe. Thus, TIMP-2 is expressed differently between the prostatic lobes and is another nearly lobe-specific protein, which plays a role in the regulation of MMP activity in seminal plasma and glandular homeostasis. TIMP-2 is also another regional ductal variation of VP. Further studies should address whether TIMP-2 expression is related to the highest incidence of rat LP prostatitis and adenocarcinoma. © 2006 International Federation for Cell Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The energy efficiency of buildings should be a goal at the pre-design phase, though the importance of the design variables is often neglected even during the design process. Highlighting the relevance of these design variables, this research studies the relationships of building location variables with the electrical energy consumption of residential units. The following building design parameters are considered: orientation, story height and sky view factor (SVF). The consideration of the SVF as a location variable contributes to the originality of this research. Data of electrical energy consumption and users' profiles were collected and several variables were considered for the development of an Artificial Neural Network model. This model allows the determination of the relative importance of each variable. The results show that the apartments' orientation is the most important design variable for the energy consumption, although the story height and the sky view factor play a fundamental role in that consumption too. We pointed out that building heights above twenty-four meters do not optimize the energy efficiency of the apartments and also that an increasing SVF can influence the energy consumption of an apartment according to their orientation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electromyography is frequently used to measure the activity of masticatory muscles. It requires the precise setting of the electrodes, which demands the accurate location of the muscle to be evaluated. The purpose of this study was to investigate the accuracy of an external method to locate the buccinator muscle. Fifteen human cadavers were evaluated and planes were etermined on the face using anatomic landmarks. An angle (α) was obtained at the intersection of these planes on the central point of buccinator muscle and measured with a protractor. The value of the angle allows locating the central point of buccinator muscle based on anatomic landmarks on the face. Statistical analysis of the collected data indicated an angle of 90° with 95% reliability, thus proving the efficacy of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molossidae species, Cynomops abrasus (2n = 34, fundamental number, FN = 64), Eumops auripendulus (2n = 42, FN = 62), Molossus rufus (2n = 48, FN = 64), Molossops temminckii (2n = 48, FN = 64), and Nyctinomops laticaudatus (2n = 48, FN = 64), and Phyllostomidae species, Phyllostomus discolor (2n = 32, FN = 60), have karyotypes with different chromosome and fundamental numbers, different localization of constitutive heterochromatin, and different numbers and location of nucleolar organizer regions (NORs). Fluorescence in situ hybridization with a human probe of the telomeric sequence (TTAGGG)n produced fluorescent signals in telomeric regions of the six bat species' chromosomes; in E. auripendulus, pericentromeric signals were also observed in the acrocentric and subtelocentric chromosomes. A relationship between telomeric sequences and NORs, and between telomeric sequences and constitutive heterochromatin was detected in chromosomes bearing NORs in C. abrasus, M. temminckii, N. laticaudatus, and P. discolor. No interstitial signal was observed in the meta- or submetacentric chromosomes of these species. ©FUNPEC-RP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to determine the mean distance between the infraorbital foramen and the infraorbital margin, as well as the mean distance between the infraorbital foramen and the piriform aperture on both sides of dry human skulls, with the aim of improving the efficiency in clinical situations, such as surgery and anesthetic procedures. Two hundred ninety-five skulls were used (590 sides), located in the Frankfurt Plane through a craniostat. The measurements were collected by two distinct operators, with a dry tip compass and carried to a caliper. The general mean obtained between the infraorbital foramen and the infraorbital margin was 6.37 mm (±1.69 mm), with a mean of 6,28 mm (±1.79 mm) on the right side and 6.45 mm (±1.76 mm) on the left side. The general mean obtained between the infraorbital foramen and the piriform aperture was 17.67 mm (±1.95 mm), being 17.75 mm (±2.10 mm) on the right side and 17.60 mm (±2.04 mm) on the left side. There were statistically significant differences between the right and left distances of the infraorbital foramen and the infraorbital margin, verified by the Student's-t test. The results of this study allow a more precise location of the infraorbital foramen, particularly as regards the infraorbital margin, since this distance is of relevant importance as a repair point during surgical procedures involving this anatomical structure.