123 resultados para Digital mammographic image receptors


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare with pristine sites bone resorption and soft tissue adaptation at implants placed immediately into extraction sockets (IPIES) in conjunction with deproteinized bovine bone mineral (DBBM) particles and a collagen membrane.Material and methods: The mesial root of the third premolar in the left side of the mandible was endodontically treated (Test). Flaps were elevated, the tooth hemi-sectioned, and the distal root removed to allow the immediate installation of an implant into the extraction socket in a lingual position. DBBM particles were placed into the defect and on the outer contour of the buccal bony ridge, concomitantly with the placement of a collagen membrane. A non-submerged healing was allowed. The premolar on the right side of the mandible was left in situ (control). Ground sections from the center of the implant as well as from the center of the distal root of the third premolar of the opposite side of the mandible were obtained. The histological image from the implant site was superimposed to that of the contralateral pristine distal alveolus, and dimensional variation evaluated for the hard tissue and the alveolar ridge.Results: After 3 months of healing, both histological and photographic evaluation revealed a reduction of hard and soft tissue dimensions.Conclusion: The contour augmentation performed with DBBM particles and a collagen membrane at the buccal aspects of implants placed IPIES was not able to maintain the tissue volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The uses of Information and Communication Technologies (ICT) and Web environments for creation, treatment and availability of information have supported the emergence of new social-cultural patterns represented by convergences in textual, image and audio languages. This paper describes and analyzes the National Archives Experience Digital Vaults as a digital publishing web environment and as a cultural heritage. It is a complex system - synthesizer of information design options at information setting, provides new aesthetic aspects, but specially enlarges the cognition of the subjects who interact with the environment. It also enlarges the institutional spaces that guard the collective memory beyond its role of keeping the physical patrimony collected there. Digital Vaults lies as a mix of guide and interactive catalogue to be dealt in a ludic way. The publishing design of the information held on the Archives is meant to facilitate access to knowledge. The documents are organized in a dynamic and not chronological way. They are not divided in fonds or distinct categories, but in controlled interaction of documents previously indexed and linked by the software. The software creates information design and view of documental content that can be considered a new paradigm in Information Science and are part of post-custodial regime, independent from physical spaces and institutions. Information professionals must be prepared to understand and work with the paradigmatic changes described and represented by the new hybrid digital environments; hence the importance of this paper. Cyberspace interactivity between user and the content provided by the environment design provide cooperation, collaboration and sharing knowledge actions, all features of networks, transforming culture globally.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A virtual studio system can use technologies as augmented reality and digital matting to decrease production costs at the same time it provides the same resources of a conventional studio. With this, it’s possible for the current studios, with low cost and using conventional devices, to create productions with greater image quality and effects. Some difficulties are recurrent in virtual studio applications that use augmented reality and digital matting. The virtual objects registration in augmented reality techniques suffer from problems caused by optical distortions in the camera, errors in the marker tracking system, lack of calibration on the equipments or on the environment (lighting, for example), or even by delays in the virtual objects display. On the other hand, the digital matting’s main problem is the real-time execution to preview the scene, which must have optimized processing speed at the same time while maintain the best image quality possible. Taking the given context into consideration, this work aims to give continuity to a virtual studio system called ARStudio, by enhancing digital matting, virtual objects registration and introducing a segmentation based on depth map, yet adding better control over functionalities previously implemented

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this letter, a semiautomatic method for road extraction in object space is proposed that combines a stereoscopic pair of low-resolution aerial images with a digital terrain model (DTM) structured as a triangulated irregular network (TIN). First, we formulate an objective function in the object space to allow the modeling of roads in 3-D. In this model, the TIN-based DTM allows the search for the optimal polyline to be restricted along a narrow band that is overlaid upon it. Finally, the optimal polyline for each road is obtained by optimizing the objective function using the dynamic programming optimization algorithm. A few seed points need to be supplied by an operator. To evaluate the performance of the proposed method, a set of experiments was designed using two stereoscopic pairs of low-resolution aerial images and a TIN-based DTM with an average resolution of 1 m. The experimental results showed that the proposed method worked properly, even when faced with anomalies along roads, such as obstructions caused by shadows and trees.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The article discusses a proposal of displacement measurement using a unique digital camera aiming at to exploit its feasibility for Modal Analysis applications. The proposal discusses a non-contact measuring approach able to measure multiple points simultaneously by using a unique digital camera. A modal analysis of a reduced scale lab building structure based only at the responses of the structure measured with the camera is presented. It focuses at the feasibility of using a simple ordinary camera for performing the output only modal analysis of structures and its advantage. The modal parameters of the structure are estimated from the camera data and also by using ordinary experimental modal analysis based on the Frequency Response Function (FRF) obtained by using the usual sensors like accelerometer and force cell. The comparison of the both analysis showed that the technique is promising noncontact measuring tool relatively simple and effective to be used in structural modal analysis