589 resultados para Dental clasps


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of the Problem: The effectiveness of low-intensity red laser for activating a bleaching gel and its effect in pulp temperature was not investigated in dental literature. Purpose: The objective of this study was to assess the effectiveness of low-intensity red laser for activating a bleaching gel, as well as its effect in temperature of the bleaching gel and the dental pulp. Materials and Methods: Forty extracted bovine teeth were immersed in a solution of coffee 14 days for darkening. The initial colors were recorded by spectrophotometric analysis. The specimens were randomly distributed into two groups (N = 20): the control, which did not receive light and the experimental group that received light from an appliance fitted with three red light-emitting laser diodes (? = 660 nm). A green-colored, 35% H2O2based bleaching gel was applied for 30 minutes, and changed three times. After bleaching, the colors were again measured to obtain the L*a*b* values. Color variation was calculated (?E) and the data submitted to the non-paired t-test (5%). To assess temperature, 10 human incisors were prepared, in which one thermocouple was placed on the bleaching gel applied on the surface of the teeth and another inside the pulp chamber. Results: There was a significant difference between the groups (p = 0.016), and the experimental group presented a significantly higher mean variation (7.21 +/- 2.76) in comparison with the control group (5.37 +/- 1.76). There was an increase in pulp temperature, but it was not sufficient to cause damage to the pulp. Conclusion: Bleaching gel activation with low-intensity red laser was capable of increasing the effectiveness of bleaching treatment and did not increase pulp temperature to levels deleterious to the pulp. CLINICAL SIGNIFICANCE The application of a low-intensity red laser was effective for activating a bleaching gel with green dye, without any deleterious increases in pulpal temperature. (J Esthet Restor Dent 24:126134, 2012)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the cohesive strength of the composite using different resinous monomers to lubricate instruments used in the Restorative Dental Modeling Insertion Technique (RDMIT).Materials and Methods: The composite specimens were made by using a prefabricated Teflon device. Different resinous monomers were used at the interface to lubricate the instruments, for a total of 72 specimens divided into 6 groups: 1. control group, no resinous monomer was used; 2. Composite Wetting Resin; 3. C & B Liquid; 4. Scotchbond Multi-Purpose Adhesive; 4. Adper Single Bond Adhesive; 6. Prime & Bond NT. Specimens were submitted to the circular area tensile test to evaluate the cohesive strength at the composite interfaces. Data were analyzed using ANOVA and Tukey's test (alpha = 0.05).Results: ANOVA showed a value of p < 0.0001, which indicated that there were significant differences among the groups. The means (SD) for the different groups were: Adper Single Bond Adhesive: 26 (12) a; control group: 28 (3) ab; Prime & Bond NT: 32 (12) ab; Composite Wetting Resin: 36 (9) abc; C&B Liquid: 38 (7) bc; Scotchbond Multi-Purpose Adhesive: 46 (10) c. Groups denoted with the same letters were not significantly different. Only Scotchbond Multi-Purpose Adhesive, used for direct restorations, had a statistically significantly higher bond strength than the control group, Adper Single Bond Adhesive, and Prime & Bond NT. Adper Single Bond with Adhesive showed a statistically significantly lower mean value than C & B Liquid.Conclusion: The results of this study indicate that the resinous monomers used for lubricating the instruments in the RDMIT did not alter the mechanical properties of the composite, and therefore did not reduce the cohesive bond strength at the composite interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study compared five types of chemical catalyzing agents added to 35% hydrogen peroxide gel, with regard to their capacity of intensifying in-office dental bleaching results.Methods: One-hundred and twenty bovine incisors were used, of which the crowns and roots were cut in the incisor-apical direction, to acquire the dimensions of a human central incisor. The specimens were sectioned in the mesiodistal direction by means of two longitudinal cuts, the lingual halves being discarded. The vestibular halves received prophylaxis with a bicarbonate jet, ultrasound cleaning and acid etching on the dentinal portion. Next, the specimens were stored in receptacles containing a 25% instant coffee solution for two weeks. After the darkening period, initial measurement of the shade obtained was taken with the Easy Shade appliance, which allowed it to be quantified by the CIELab* method. The samples were divided into six groups, corresponding to the chemical activator used: a) none (CON); b) ferric chloride (CF); c) ferrous sulphate (SF); d) manganese gluconate (GM); e) manganese chloride (CM); f) mulberry root extract (RA). Each group received three 10-minute applications of the gels containing the respective activating agents. Next, a new shade measurement was made.Results: The Analysis of Variance and Tukey tests (alpha=5%) showed statistically significant differences for the shade perception values (p=0.002). Groups GM, CM and RA showed significantly higher means than the control group.Conclusion: The presence of some chemical activators is capable of resulting in a significant increase in tooth shade variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two self-etching primers (P) and two all-in-one self-etching adhesives (S). Method: Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to the adhesive system.. SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (inner diameter of 0.8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37 degrees C for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test (a=5%). Samples were also subjected to stereomicroscopic and SEM evaluations after micro-shear testing. Mean bond strength values (MPa +/- SD) and the results of Tukey test were: SB2: 36.36(+/- 3.34)a; ADS: 33.03(+/- 7.83)a; XE3: 32.76(+/- 5.61)a; CSE: 30.61(+/- 6.68)a; PLP: 22.17(+/- 6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. J Clin Pediatr Dent 35(3): 301-304, 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to describe how to evaluate and quantify the ergonomic satisfaction level of dental clinics rooms. Requirements for design, production and selection of dental equipment as described in ISO/TC-106/SC-6-N-411, support more comprehensive studies for an ergonomic evaluation and ergo design of the dental workstations. It was created a checklist of ergonomics requirements which is supported by Standards ISO/FDI and acquired by mean of a literature review. According to information exposed at the document of the Ergonomics Society of Dental Ergonomics - ESDE we can consider that the elaboration of an ergonomic evaluation protocol regard to the dental workstation is an important demand for the ergonomics, particularly in relation to the performance of the ergonomic design which presents qualified to assist to dental equipment manufactures. By this means, the identification of the evaluation factors pointed in ISO/TC 106/SC 6 N 411 offers the basic information to the process of elaboration of this protocol addressed by the described general guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The corrosion resistance of three of the constituent phases in high copper dental amalgams has been investigated by electrochemical methods in 0.9% NaCl solution. Polarization curves show corrosion potentials most positive for gamma(1)-Ag2Hg3, followed by Ag-Cu, and gamma-Ag3Sn in agreement with the order of corrosion resistance deduced from the corrosion currents. Complex plane impedance plots at the open circuit potential showed distorted semicircles with diffusional components at low frequency for Ag-Hg and Ag-Cu, while for gamma-Ag3Sn a layer of corrosion products is formed, partially or completely covering the surface of the electrode. Impedance and noise spectra have been compared in the frequency domain, and show good agreement. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental amalgams, formed by reaction of mercury with a powder alloy containing mainly Ag, Sn, Cu and Zn, have a complex metallurgical structure which can contain up to six phases. Their observed corrosion is thus a complex process, which involves contributions from each of the phases present as well as intergranular corrosion. It is thus of interest to investigate the corrosion of individual phases present in dental amalgams. In this work the corrosion behaviour in 0.9% NaCl solution of Ag-Hg, Ag-Sn and Sn-Hg phase components of dental amalgams was investigated by electrochemical methods. The corrosion resistance was found to decrease in the order gamma (1)-Ag2\Hg3, gamma -Ag3Sn and gamma (2)-Sn7Hg. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metallographic studies by scanning electron microscopy and energy dispersive spectroscopy carried out for two types of dental amalgam showing a porous multiphase material. Surface analysis shows that the structure of the Dispersalloy amalgam consists of gamma-Ag3Sn, gamma(1)-Ag2Hg3, eta'-Cu6Sn5, epsilon-Cu3Sn and eutectic Ag-Cu phases. while Velvalloy amalgam consists mainly of gamma, gamma(1) and gamma(2)-Sn7-8Hg phases. The latter phase presents an uniform distribution often associated with voids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This prospective clinical study was conducted with the purpose of evaluating the influence of the banded Herbst appliance on dental changes during the early treatment of Class II malocclusion. METHOD: The sample consisted of 15 prepubertal subjects (12 boys and 3 girls, initial age: 9 years and 6 months) who were treated with the Herbst appliance. Treatment effects were compared with those of a Class II Division 1 group of 15 subjects (8 boys and 7 girls, mean initial age 9 years and 1 month), not treated orthodontically. Statistical analysis was performed using Student t-test with 5% significance level. RESULTS: The results showed that treatment with the banded Herbst appliance in the mixed dentition stage tended to upright maxillary incisors (mean: 4.14°). The maxillary molars were distalized and intruded significantly (mean 2.65 mm and 1.24 mm, respectively), the lower incisors slightly protruded anteriorly (mean 1.64 mm) and the molars showed no significant changes in the horizontal and vertical directions. Furthermore, significant improvements were noted in overbite (1.26 mm), overjet (4.8 mm) and molar relationship (12.08 mm). CONCLUSIONS: Changes in the upper dental arch were found to be greater than changes in the lower arch. Furthermore, mandibular anchorage loss was reduced due to the anchorage system used in the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fez-se o acompanhamento radiográfico mensal da erupção dental de cinco fêmeas e sete machos da espécie Agouti paca durante 30 meses. Os animais foram radiografados mês-a-mês. As pacas nasceram com três dentes em cada hemiarcada dental, um incisivo de crescimento contínuo por toda a vida, um pré-molar decíduo (o único que é decíduo) e um molar. No quarto mês houve a erupção do segundo molar. O nivelamento da superfície de oclusão dos dentes inferiores ocorreu no sexto mês e o dos superiores ao redor do nono mês. No 14° mês, houve o início da erupção do terceiro molar e, no 16° mês, a evidenciação radiográfica do pré-molar permanente, ainda com preservação de correspondente decíduo. No 21° mês, ocorreu o nivelamento da superfície de oclusão dos quatro dentes superiores e inferiores. Entre o 22° e o 24° mês, iniciou-se a queda dos pré-molares decíduos inferiores e, entre o 23º e o 24° mês, a dos superiores. Entre o 24º e o 25º mês, a superfície de oclusão dos dentes inferiores estava nivelada, e a dos dentes superiores aconteceu no 27º mês.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo foi realizado objetivando estudar o efeito das práticas de alimentação infantil e de fatores associados sobre a ocorrência de cárie dental. Para isso, determinou-se o ceo-d e o ceo-s em 156 crianças de 18 a 48 meses e foi aplicado às mães um questionário incluindo perguntas sobre a ocupação do pai, nível educacional da mãe, higiene bucal, época de erupção do dente e sobre práticas de alimentação infantil. Os dados obtidos foram analisados através dos testes X2 e Mann-Whitney U. A média do ceo-s foi 3,4 com 40% das crianças livres de cáries, sendo que 36 e 24% tinham um ceo-d maior que 0 e 4, respectivamente. Notou-se que 72% das crianças eram alimentadas ao seio, 17% apenas com mamadeira e 10% pelos dois meios. Das crianças alimentadas apenas com mamadeira 70% apresentaram cárie. A cárie de mamadeira foi observada em 20% das crianças, sendo que 77% destas tinham sido alimentadas por mais de 12 meses. As crianças, cujos pais eram profissionais com terceiro grau de escolaridade, tiveram significativamente menos cárie do que aquelas de pais com nível técnico ou pais operários. A prevalência de cárie na faixa etária estudada foi relativamente alta. As crianças com cárie de mamadeira tenderam a manter seus hábitos de aleitamento por mais de 12 meses, sendo que o uso de mamadeira açucarada estava presente em 100% dos casos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foi objetivo deste trabalho estudar a reação do tecido pulpar ao capeamento com agregado de trióxido mineral (MTA) branco. Para isto, foram utilizados 15 dentes de cães, onde após o preparo de cavidades na região cervical da face vestibular e exposição pulpar, estas foram capeadas com MTA branco. Os animais foram sacrificados após 60 dias do término dos procedimentos clínicos e os dentes processados em laboratório para obtenção de cortes histológicos. Foi observada formação de ponte de tecido duro em todas as polpas. em alguns casos, não havia dentina tubular mas somente uma estrutura de aspecto morfológico peculiar, selando a cavidade de exposição pulpar. Apenas dois casos apresentaram inflamação pulpar. Conclui-se que o MTA branco possui as características necessárias de um material para capeamento pulpar.