127 resultados para DIAGNÓSTICO POR IMAGEM


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: To establish the best methodology for diagnosis and management of patients with solid and complex renal masses by comparing the costs and benefits of different imaging methods and to improve differential diagnosis of these benign and malignant lesions, particularly by investigating tumour calcifications. Methods: We performed a prospective study on 31 patients with solid or complex masses by submitting them to Abdominal Ultrasonography (US), Doppler Ultrasonography of the renal mass (US Dop), Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Results: We found 28 patients with malignant and three with benign masses. Of the 28 malignant, 17 showed calcifications at CT; 16 central and one was of the pure peripheral curvilinear type (egg shell). Excretory Urography (IVP) had a significantly lower detection rate for central calcifications than both US and CT. Benign and malignant masses appeared as described in literature, with US, CT and MRI showing high sensitivity and specificity in renal tumor diagnosis. The exception was US Dop where we obtained lower sensitivity for the characterization of malignant tumor flow. Conclusions: In this series we were surprised to find that CT revealed central calcifications in 51.6% of patients, all with malignant lesions, while, literature reports a frequency of calcification in renal cell carcinoma between 8 and 22%, in studies using abdominal films and EU (IVP). This finding is of great importance when we consider that these calcifications occur particularly in malignant neoplasms. As a result of comparing these different imaging methods we have developed a better methodology for renal tumor investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To establish benchmarks and study some sonographic characteristics of the thyroid gland in a group of euthyroid children aged up to 5 years as compared with age-matched children with congenital hypothyroidism. Thirty-six children (17 female and 19 male) aged between 2 months and 5 years were divided into two groups - 23 euthyroid children and 13 children with congenital hypothyroidism - and were called to undergo ultrasonography. In the group of euthyroid children (n = 23), mean total volume of the thyroid gland was 1.12 mL (minimum, 0.39 mL; maximum, 2.72 mL); a homogeneous gland was found in 17 children (73.91%) and 6 children (26.08%) had a heterogeneous gland. In the group of children with congenital hypothyroidism (n = 13), mean total volume of the thyroid gland was 2.73 mL (minimum, 0.20 mL; maximum, 11.00 mL). As regards thyroid location, 3 patients (23.07%) had ectopic thyroid, and 10 (69.23%) had topic thyroid, and out of the latter, 5 had a homogeneous gland (50%) and 5, a heterogeneous gland (50%). In the group with congenital hypothyroidism, 6 (46.15%) children had etiological diagnosis of dyshormoniogenesis, 3 (23.07%), of ectopic thyroid, and 4 (30.76%), of thyroid hypoplasia. Thyroid ultrasonography is a noninvasive imaging method, widely available, easy to perform and for these reasons could, and should, be performed at any time, including at birth, with no preparation or treatment discontinuation, to aid in the early etiological definition of congenital hypothyroidism.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In veterinary medicine, the same clinician usually follows an animal from birth to old age, whereas in human medicine different specialists are required. It is therefore essential that veterinarians know the normal imaging, biochemical, hematological and physical exam values for younglings, which differ significantly from those of adults of the same species. Abdominal radiographies of young animals are poorly defined due to differences in tissue constitution in relation to adults. These same factors, however, substantially improve sonographic images of the region. Nonetheless, the interpretation of B-mode sonographic findings in puppies is difficult due to the lack of information about the normal parameters in this phase of life. The objective of this study was to compile information about peculiarities of abdominal B-mode ultrasonography in puppies and kittens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)