146 resultados para DENTIN SENSITIVITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the bond strength between human dentin and composites, using two light-activated single-bottle total-etch adhesive systems with different pHs combined with chemically activated and light-activated-composites. The tested hypothesis was that the dentin bond strength is not influenced by an adhesive system of low pH, combined with chemically activated or light-activated composites. Material and Method: Flat dentin surfaces of twenty-eight human third molars were allocated in 4 groups (n=7), depending on the adhesive system: (One Step Plus-OS and Prime & Bond NT-PB) and composite (light-activated Filtek Z-100 [Z100] and chemically activated Bisfil 2B [B2B]). Each adhesive system was applied on acid-etched dentin and then one of the composites was added to form a 5 mm-high resin block. The specimens were stored in tap water (37 degrees C/24 h) and sectioned into two axes, x and y. This was done with a diamond disk under coolant irrigation to obtain beams with a cross-section area of approximately 0.8 mm(2). Each specimen was then attached to a custom-made device and submitted to the microtensile test (1 mm.min(-1)). Data were analyzed using two-way ANOVA and Tukey's tests (p<0.05). Results: the anticipated hypothesis was not confirmed (p<0.0001). The bond strengths (MPa) were not statistically different between the two adhesive systems when light-activated composite was used (OS+Z100 = 24.7 +/- 7.1(a); PB+Z100 = 23.8 +/- 5.7(a)). However, with use of the chemically activated composite (B2B), PB (7.8 +/- 3.6(b) MPa) showed significantly lower dentin bond strengths than OS (32.2 +/- 7.6(a)). Conclusion: the low pH of the adhesive system can affect the bond of chemically activated composite to dentin. on the other hand, under the present conditions, the low pH did not seem to affect the bond of light-activated composites to dentin significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an environmental oil spill sensitivity map of Cardoso Island State Park, located in São Paulo state, Brazil, including some of its surrounding areas. This map was designed following the procedures determined by the Brazilian Federal Environment Organ (Ministry of the Environment), which separates coastal habitats in different littoral sensitivity indexes (LSI) to oil spills. We have also analysed some seasonal variations in morphologic and textural parameters at the local marine beaches that could affect their sensitivity, having found that they are more sensitive during summer due to a wider foreshore zone during these periods. Local most sensitive habitats are estuarine mangroves (LSI 10) and estuarine mud banks (LSI 9). Marine beaches were ranked LSI 3, and littoral rocky shores were subdivided in exposed flat rocky shores (LSI 1), boulder rocky shores (LSI 6) and sheltered rocky shores (LSI 8). Due to the elevated sensitivity of an estuarine system in the area, we considered necessary the installation of an Environmental Emergency Centre and the design of an emergency plan for the region in case of an accident resulting in oil spills within its vicinities. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cucumis anguria present dark germinating seeds at 25 degrees C. Seeds without the tegument are photosensitive germinating better in darkness than under continuous white light. However, pre-incubation at 40 degrees C for 48 hours allows the seeds to germinate under continuous white light and the incubation of naked seeds at -0.6MPa restored the light inhibition of seed germination. Our results suggest that the tegument interact with the phytochrome in the control of seed germination in part of the population of seed of C. anguria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the effect of different bur types and acid etching protocols on the shear bond strength (SBS) of a resin modified glass ionomer cement (RM-GIC) to primary dentin. Forty-eight clinically sound human primary molars were selected and randomly assigned to four groups (n=12). In G1, the lingual surface of the teeth was cut with a carbide bur until a 2.0-mm-diameter dentin area was exposed, followed by the application of RM-GIC (Vitremer - 3M/ESPE) prepared according to the manufacturer's instructions. The specimens of G2, received the same treatment of G1, however the dentin was conditioned with phosphoric acid. In groups G3 and G4 the same procedures of G1 and G2 were conducted respectively, nevertheless dentin cutting was made with a diamond bur. The specimens were stored in distilled water at 37 degrees C for 24h, and then tested in a universal testing machine. SBS. data were submitted to 2-way ANOVA (= 5%) and indicated that SBS values of RM-GIC bonded to primary dentin cut with different burs were not statistically different, but the specimens that were conditioned with phosphoric acid presented SBS values significantly higher that those without conditioning. To observe micromorphologic characteristics of the effects of dentin surface cut by diamond or carbide rotary instruments and conditioners treatment, some specimens were examined by scanning electron microscopy. Smear layer was present in all specimens regardless of the type of rotary instrument used for dentin cutting, and specimens etched with phosphoric acid presented more effective removal of smear layer. It was concluded that SBS of a RM-GIC to primary dentin was affected by the acid conditioning but the bur type had no influence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. The effects of swimming-induced stress on rat sensitivity to norepinephrine were studied.2. Through microscopic analysis of the stomach from swimming stressed rats significant ulceration was observed, confirming that the stress situation was really present.3. Sensitivity to norepinephrine either in the presence or in the absence of cocaine and propranolol in acutely swimming stressed rats was not altered significantly.4. Bilateral adrenalectomy was performed in rats 2 days before swimming and acute stress resulted in a supersensitivity to norepinephrine, indicating that adrenal glands may, at least, partially mediate the sensitivity to this drug in vasa deferentia isolated from these animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the pre-emptive analgesic effect of pre-incisional epidural ketamine.Study Design A blinded, randomized experimental study.Animals Sixteen mixed breed mares, 17.6 +/- 2.8 years old, weighing 352 +/- 32 kg.Methods In a pilot study, an incision was made on one lateral thigh using a lidocaine block and no further analgesics, and it was verified that the nociceptive threshold was lower on the incised side than nonincised side (p < 0.05), and that von Frey filaments evoked a pain response. The 16 animals were divided into group A (ketamine, n = 9) and B (saline, n = 7). An epidural catheter was inserted 24 hours before the trials, the thigh was shaved bilaterally, and the right side was blocked (incised side) using lidocaine. Twenty-five minutes later, ketamine (A) or saline (B) was administered epidurally. Five minutes later, a 10-cm. skin incision was made on the right side, and then sutured. Nociceptive threshold was determined with von Frey filaments at 1, 3, and 5 cm. around the incision at 15-minute intervals for 2 hours, then at 4, 6, and 8 hours. Behavioral alterations, heart and respiratory rates were recorded. Nociceptive thresholds from these points were averaged to obtain mean values at each time, converted to a logarithmic scale, and submitted to a nonparametric analysis (Mann-Whitney and one-way repeated measures anova test,p less than or equal to 0.05).Results After 8 hours, the global range score revealed reduced hyperalgesia (p < 0.01) around the incision in 92% (4.65-4.27) of evaluated intervals in group A (ketamine). There were no significant changes in behavior, heart and respiratory rates,Conclusions It was concluded that pre-emptive epidural ketamine reduced post-incisional pain in the horse, and that von Frey filaments were able to quantify cutaneous sensitivity after tissue damage.Clinical relevance Epidural ketamine injection can reduce post-incisional sensitivity in the horse.