125 resultados para Amplificador de instrumentação
Resumo:
The objective of this review was reporting an overview about the properties of two irrigating solutions, solution of sodium hypochlorite and chlorhexidine, used in the treatment of root canals. A solution must submit irrigating antimicrobial action, dissolve waste tissue, promote wetting to facilitate the instrumentation, and present biocompatibility with the adjacent tissues. The sodium hypochlorite used in different concentrations has been the solution of choice among professionals by presenting antimicrobial action and act as a solvent tissue. However, today, chlorhexidine has been widely used as an irrigating solution due to specific properties that enable its use, such as substantivity, antimicrobial effectiveness, and low toxicity. Thus the solution of chlorhexidine with different concentrations is presented as an alternative to irrigating solution for the treatment of root canals.
Resumo:
Objective: The objective of this paper was to verify if the final irrigation at 17% EDTA, separately or followed by chlorhexidine digluconate at 2% interferes on the apical marginal leakage in root canal overfilling, due to the use of two root canal filling materials (Sealer 26TM or SealapexTM). Methods: Forty lower incisors extracted, with a single root canal, were biomechanically prepared, at 2.0mm beyond the radicular apex, with ProTaper SystemTM, finishing it with the F3 instrument. Irrigation was accomplished with 1.0 mL NaOCl at 2.5% at each change of equipment caliper and, in the end, with 5.0 mL normal saline solution. After achieving this procedure, the foraminal channels was standardized with a file K 25 until its DO appears in the foraminal opening. From this moment, the teeth were subdivided into two groups of 20 specimens each, because of the final irrigation method used: I – irrigation with EDTA at 17% for 3min and II – identical protocol, thus, after EDTA aspiration at17%, it was again irrigated with chlorhexidine digluconate at 2%, also kept intra-canal for 3min. Each group was again sub-divided into two sub-groups (ten teeth each), according to the cement used (Sealer 26TM or SealapexTM), and filled by using a single gutta-percha F1 (ProTaperTM, Universal Filling), in such a manner that it goes 2.0 mm beyond the radicular apex. Soon after that, the teeth were immersed in Rhodamine BTM for 72h, vacuum and after the roots have been bucolingually grooved, the leakages marked were measured with program Image ToolTM. Results and Conclusions: The leakage magnitude was similar among themselves (p > 0.05), except for group Sealapex®, thus the final use with chlorhexidine reduced apical leakage (p < 0.05).
Resumo:
The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. OBJECTIVE: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. MATERIAL AND METHODS: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey's test. The level of significance was set at P < 0.05. RESULTS: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. CONCLUSION: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.
Resumo:
Introduction: The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. Objective: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. Material and methods: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey’s test. The level of significance was set at P < 0.05. Results: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. Conclusion: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.
Resumo:
Periodontal treatment of teeth with furcation lesions often have unpredictable results due to several factors that may hinder therapy or influence the progress of periodontal disease. Of these, the length of the root trunk may contribute to the early injury of the furcations or even cause complications for the application of the treatment; the opening of the roots can guide the type of treatment to be instituted and cervical enamel projections may hinder the instrumentation of the region or even act as a retention plate niche. Thus, the purpose of this study was measured using a digital caliper, root logs database 400 molar both the 1st and the 2nd and both upper and lower as well as analyze using appropriate index type projection cervical enamel and through appropriate classification the opening of the roots in order to guide the diagnosis and treatment plan. We conclude that there is variation in measures of root trunk between the faces of the teeth examined and that greater cervical enamel projection (ECP) correlates with a decrease in the length of the root trunk in the sample evaluated as the first molars have higher occurrence of roots with a degree of opening larger than the second molars.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Linguística e Língua Portuguesa - FCLAR
Resumo:
Pós-graduação em Educação Matemática - IGCE
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
Introdução: a eliminação de bactérias dos canais radiculares é essencial no tratamento endodôntico de dentes com polpas necrosadas, desde que bactérias não só causam, mas também mantêm, as lesões periapicais. Objetivo: analisar in vivo a influência de soluções irrigantes (NaOCl 1%, NaOCl 2,5%, solução salina estéril 0,9%) no tratamento de dentes de cães com lesão periapical crônica em sessão única. Métodos: quarenta canais radiculares de três cães da raça Beagle permaneceram expostos à cavidade bucal para permitir a contaminação e a formação de lesões periapicais crônicas. Em seguida, os canais radiculares foram preparados biomecanicamente. Durante a instrumentação, três soluções irrigantes foram utilizadas: G1 – NaOCl 2,5%; G2 – NaOCl 1%; G3 – solução salina estéril 0,9%. O grupo controle (G4) não recebeu tratamento nem selamento coronário. Os canais radiculares foram obturados com cones de guta-percha e Sealapex. As aberturas coronárias foram seladas com IRM e amálgama. Após 6 meses, os animais foram sacrificados e blocos de tecido processados histologicamente para serem corados com hematoxilina e eosina, ou Brown e Brenn. Resultados: não houve diferença histológica significativa entre a utilização de hipoclorito de sódio a 1% ou 2,5% (p>0,05), mas houve entre eles e a solução salina estéril a 0,9% (p<0,05). Conclusão: concluiu-se que o uso de soluções irrigantes com potencial antibacteriano (hipoclorito de sódio a 1% e 2,5%) proveu condições mais favoráveis ao processo de reparo.
Resumo:
Este artigo apresenta uma avaliação de um protótipo relativo a um experimento de cinemática que pode ser controlado remotamente via internet. Para tanto, utilizamos microcontroladores da família PIC, visando controlar a velocidade de carrinhos de brinquedo. O intuito foi investigar a possibilidade de se construir um laboratório de Ensino de Física totalmente controlado remotamente com vistas a apoiar cursos de formação inicial e continuada de professores ministrados a distância. A avaliação do protótipo foi realizada por 15 alunos de um curso presencial de Graduação em Física, no âmbito da disciplina de Instrumentação para o Ensino da Física. Os resultados apontam para a viabilidade da utilização desse recurso.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Objetivo: O presente estudo buscou um indicador de classificação de presença de dor lombar baseado no tempo de resistência isométrica e em variáveis eletromiográficas. Material e Métodos: Para tanto participaram do presente estudo 40 voluntários do gênero masculino, os quais foram divididos em dois grupos de 20 voluntários, a saber: grupo sem dor lombar e grupo com dor lombar. Para a captação dos sinais eletromiográficos foram utilizados eletrodos de superfície descartáveis passivos de contato bipolar de Ag/AgCl conectados a um pré-amplificador de ganho de 20 vezes. A distância intereletrodos foi fixa em 20mm. Os eletrodos foram dispostos bilateralmente sobre os músculos longuíssimo do tórax, iliocostal lombar e multífido lombar. Foi utilizado um módulo de aquisição de sinais biológicos de 8 canais no qual foram conectados os eletrodos. Para a aquisição dos sinais foi utilizado um software específico (Aqdados 7-Lynx®) com a freqüência de amostragem calibrada em 2000 Hz. Com os equipamentos preparados e os eletrodos conectados os voluntários realizaram o teste de Sorensen, o qual consiste em sustentar o peso do tronco, em posição horizontal, até a exaustão voluntária. Para a análise dos sinais eletromiográficos foram utilizadas rotinas específicas em ambiente MatLab (MathWorks®). Neste software foi obtida a atividade eletromiográfica dos músculos selecionados durante o teste de contração isométrica até a exaustão para a determinação dos valores de root means quare (RMS) em pacotes de 1s a cada 0.5s (overlap). De cada espectro foram determinados os valores de frequência mediana (FM) e frequência média (Fmed) do sinal. Com a RMS, FM e Fmed foram obtidos também os valores de Razão ML/LT, Razão ML/IL e Razão IL/LT para cada variável. Com isto, os valores de RMS, FM e Fmed, juntamente com os valores de Razão ML/LT, Razão ML/IL e Razão IL/LT de cada variável, foram associados com o tempo...