101 resultados para ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lower gastrointestinal tract neoplasms are rare in domestic animals, representing 3% of all biopsies and necropsies. Our objective is to describe the histopathological and B-mode ultrasound findings in a case of duodenal adenocarcinoma in a dog, since it commonly occurs in the large intestine. On ultrasound examination, there was transmural wall thickening in the duodenum with loss of layer structure, focal peritonitis and adenopathy. Histopathological examination of the intestinal mass revealed a malignant epithelial neoplasm, densely cellular and infiltrative, extending through the lamina propria, submucosa, muscle and hypodermis, characterizing a duodenal adenocarcinoma. We conclude that adenocarcinomas may be included in the differential diagnosis of transmural lesions in the duodenum in B-mode ultrasound examinations, but a laparotomy and biopsy are required for definitive diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveThis study aimed to evaluate the benefit and specifically the feasibility of using ultrasound in ophthalmologic periconal block, and the occurrence of complications.Study designProspective experimental study.AnimalsTen healthy New Zealand White rabbits (6-8months of age), weighing 2.0-3.5kg.MethodsRabbits were anesthetized by intramuscular injection of acepromazine (1mgkg(-1)), ketamine (30mgkg(-1)) and xylazine (3mgkg(-1)). Ultrasound-assisted periconal block with lidocaine was performed on 18 eyes. Intraocular pressure was measured by applanation tonometry whereas corneal sensitivity was assessed using an esthesiometer, before and after each periconal anesthesia.ResultsIn all 18 eyes, it was possible to adequately visualize the needle shaft within the periconal space, as well as muscular cone, optic nerve and local anesthetic solution spread. Lidocaine 2% without epinephrine (0.790.19mL) was injected into the periconal space. There was no statistical difference between the intraocular pressure (meanSD) measured before (10.9 +/- 2.9mmHg) and after (11.9 +/- 3.8mmHg) the periconal anesthesia (p=0.38). The effectiveness of the ultrasound-assisted technique was shown according to the values for corneal sensitivity, assessed before and after periconal anesthesia (p<0.0001). Complications were not observed in this study.ConclusionsEye ultrasonography allowed visualization of all anatomic structures necessary to perform a periconal block, as well as the needle insertion and anesthetic spread in real time. Further studies are required to prove the real potential of ultrasound for reducing the incidence of complications associated with ophthalmic blocks, especially when anatomic disorders of the eye could potentially increase the risk.Clinical relevanceUltrasonography is a painless, noninvasive tool that may improve safety of ophthalmic regional blocks, potentially by reducing the prevalence of globe perforation or penetration of the optic nerve associated with the needle-based techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the pain intensity of patients administered midazolam and fentanyl citrate before undergoing transrectal ultrasound-guided prostate biopsy. This was a study in patients with different indications for prostate biopsy in whom 5 mg of midazolam and 50 µg of fentanyl citrate was administered intravenously 3 minutes before the procedure. After biopsy, pain was assessed by use of a visual analogue scale (VAS) in three stages: VAS 1, during probe introduction; VAS 2, during needle penetration into prostate tissue; and VAS 3, in the weeks following the exam. Pain intensity at these different times was tested with stratification by age, race, education, prostate volume, rebiopsy, and anxiety before biopsy. Pain was ranked according to the following scores: 0 (no pain), 1-3 (mild pain), 4-7 (moderate pain), and 8-10 (severe pain). Statistical analysis was performed by using Kruskal-Wallis and Wilcoxon two-tailed tests with a significance of 5%. Pain intensity was not influenced by any risk factors. The mean VAS 1 score was 1.95±1.98, the mean VAS 2 score was 2.73±2.55, and the mean VAS 3 score was 0.3±0.9, showing greater pain at the time of needle penetration than in other situations (VAS 2>VAS 1>VAS 3, p=0.0013, p=0.0001, respectively). Seventy-five percent of patients reported a VAS pain scale of less than 3.1 or mild pain. Intravenous sedation and analgesia with midazolam and fentanyl citrate is a good method for reducing pain caused by prostate biopsy, even during probe insertion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of ultrasonic vibration on the tensile strength required to remove intraradicular post cemented with different materials. Bovine teeth were selected, and 7 mm of the cervical root canals were prepared to size 5 Largo drill, the posts were cemented with zinc phosphate, Enforce (resin) or Rely X (glass ionomer). The specimens were divided into six groups (n = 10), according to the following procedures: GI-cementation with zinc phosphate associated with traction force; GII-cementation with zinc phosphate associated with ultrasonic activation and traction force; G111-cementation with Enforce associated with traction force; GIV-cementation with Enforce associated with ultrasonic activation and traction force; GV-cementation with Rely X associated with traction force; and GVI-cementation with Rely X associated with ultrasonic activation and traction force. The tensile test was conducted using the electromechanical testing machine, the force was determined by a specialized computer program and ultrasonic activation using the Jet Sonic Four Plus (Gnatus) device in 10P. Concerning to average ranking, GI showed statistically significant difference in comparison with GII and GVI (p < 0.05); there was no statistical difference in GIII and GIV when compared to other groups (p > 0.05). The ultrasound favored the intraradicular post traction regardless of the employed cement in greater or lesser extent. The post removal is a routine practice in the dental office, therefore, new solutions and better alternatives are need to the practitioner. We did not find in the literature many articles referring to this practice. Thus, the results from this study are relevant in the case planning and to promote more treatment options.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to identify candidate genes and genomic regions associated with ultrasound-derived measurements of the rib-eye area (REA), backfat thickness (BFT) and rumpfat thickness (RFT) in Nellore cattle. Data from 640 Nellore steers and young bulls with genotypes for 290 863 single nucleotide polymorphisms (SNPs) were used for genomewide association mapping. Significant SNP associations were explored to find possible candidate genes related to physiological processes. Several of the significant markers detected were mapped onto functional candidate genes including ARFGAP3, CLSTN2 and DPYD for REA; OSBPL3 and SUDS3 for BFT; and RARRES1 and VEPH1 for RFT. The physiological pathway related to lipid metabolism (CLSTN2, OSBPL3, RARRES1 and VEPH1) was identified. The significant markers within previously reported QTLs reinforce the importance of the genomic regions, and the other loci offer candidate genes that have not been related to carcass traits in previous investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-frequency ultrasound is a non-invasive tool used in skin ageing research to assess dermis thickness and echogenicity. This study evaluated the reliability of a range of high-frequency ultrasound parameters and tested their correlation with age and a validated clinical scale for the assessment of forearm skin photoageing; the difference between two body sites according to environmental exposition patterns was also investigated. Twenty-three volunteers aged 28-82 years were divided into three groups according to forearm photoageing degree. A 20 MHz ultrasound unit was used to obtain cross-sectional images of the skin by two trained investigators on two different sites: the dorsal forearm (chronically photoexposed skin) and the proximal medial arm (non-photoexposed skin). Several echogenicity parameters were studied for each skin compartment: total dermis, upper dermis and lower dermis, and the ratio between upper and lower dermis. The intraclass correlation coefficient (for complete agreement) between investigators was higher for upper and total dermis echogenicity measures compared with the lower dermis. At the non-photoexposed site, the upper and lower dermis parameter ratio was better correlated with age. At the photoexposed area, total dermis parameters demonstrated higher correlations with clinical score. The authors discuss the choice of parameters for forearm photoageing assessment using high-frequency ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of lineage of oocytes donors on the number and quality of oocytes obtained through ultrasound-guided follicular aspiration in Nellore breed cows derived from two lineages of bulls (Karvadi; K and Taj-Mahal; T). Both maternal (Km and Tm) and paternal (Kp and Tp) lineages, as well as their combinations were investigated. Oocyte aspirations were repeatedly performed with an aspiration interval of 15 days in 56 donor females. Recovered cumulus oocyte-complexes (COCs) were counted, morphologically examined and classified into seven categories (grades from I to VII) according to the number of layers of the cumulus oocyte and cytoplasm appearance. The mean number of oocytes retrieved from donors of lineage Tp-Tm was significantly higher (28.23±1.92, P<0.05) than those obtained from lineages Kp-Tm, Kp-Km, and Tp-Km (21.34±1.32, 21.28±1.73, and 16.72±1.31, respectively). There was no significant difference in the mean number of recovered oocytes between donors of lineages Kp-Km and Kp-Tm, whereas animals of lineage Tp-Km yielded the lowest number of oocytes. Higher mean number of grade III oocytes was recovered from donors of lineage Kp than lineage Tp (10.11±0.66 versus 8.79±0.58, respectively), with more grade III oocytes being obtained in both lineages as compared to the others. Paternal lineage did not influence the quality of recovered oocytes in any other category, but both Kp and Tp yielded a great mean number of oocytes graded as I, II, and III (3.14±0.21; 4.93±0.33, and 10.11±0.66 versus 3.19±0.21, 5.59±0.44, and 8.79±0.58, respectively) than those classified as IV, V, VI, and VII. However, when considering the data from the maternal lineage significantly more oocytes (P<0.05) of grade I, II and III were obtained from Taj-Mahal (11.67 ± 0.67, 5.9±0.42 and 3.64±0.25, respectively) than for lineage Karvadi, with similar results for oocytes of grades IV, V, VI, and VII. Similarly to the paternal lineage, the number of oocytes of grade III was superior (P<0.05) when compared to other categories for both lineages. In conclusion, we demonstrate here a direct influence of lineage of oocyte donor on the production and quality of oocytes obtained through ultrasound-guided follicular aspiration in Nellore cows.