245 resultados para points in agreement


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pristimerin has been shown to be cytotoxic to several cancer cell lines. In the present work, the cytotoxicity of pristimerin was evaluated in human tumor cell lines and in human peripheral blood mononuclear cells (PBMC). This work also examined the effects of pristimerin (0.4; 0.8 and 1.7 mu M) in HL-60 cells, after 6, 12 and 24 h of exposure. Pristimerin reduced the number of viable cells and increased number of non-viable cells in a concentration-dependent manner by tripan blue test showing morphological changes consistent with apoptosis. Nevertheless, pristimerin was not selective to cancer cells, since it inhibited PBMC proliferation with an IC50 of 0.88 PM. DNA synthesis inhibition assessed by 5-bromo-2'-deoxyuridine (BrdU) incorporation in HL-60 cells was 70% and 83% for the concentrations of 0.4 and 0.8 mu M, respectively. Pristimerin (10 and 20 mu M) was not able to inhibit topoisomerase 1. In AO/EB (acridine orange/ethidium bromide) staining, all tested concentrations reduced the number of HL-60 viable cells, with the occurrence of necrosis and apoptosis in a concentration-dependent manner, results in agreement with trypan blue exclusion findings. The analysis of membrane integrity and internucleosomal DNA fragmentation by flow cytometry in the presence of pristimerin indicated that treated cells underwent apoptosis. The present data point to the importance of pristimerin as representative of an emerging class of potential anticancer chemicals, exhibiting an antiproliferative effect by inhibiting DNA synthesis and triggering apoptosis. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O rio Corumbataí é um dos principais tributários da margem direita do rio Piracicaba que é um tributário do rio Tietê. O rio Corumbataí integra a bacia do rio Paraná e é regionalmente importante não só por possuir águas de boa qualidade, mas também por possuir elementos raros na paisagem local. Este estudo visou caracterizar as assembléias de peixes do rio Corumbataí e fornecer dados que contribuam para uma avaliação da sua qualidade ambiental. Na bacia do rio Corumbataí, foram amostrados 4 rios principais, cada um com 3 pontos de coleta. Vinte e quatro amostras foram coletadas durante os meses de março a julho e de setembro a dezembro de 2001. Dados bióticos foram avaliados por medidas de diversidade. Um modelo linear ANCOVA foi utilizado para testar a hipótese de variação espaço-temporal nas assembléias de peixes, com a riqueza de espécies como variável resposta, ordem do rio como fator e temperatura e logaritmo natural do número de indivíduos como covariáveis. Esta análise mostrou uma variação espaço-temporal que é corroborada por conceitos exaustivamente discutidos na literatura, tais como relação espécie-área e o conceito de rio contínuo. Dados provenientes do rio Ribeirão Claro mostraram um padrão diferente quando comparados com os outros rios. Esta diferença foi provavelmente devido à interferência humana e atesta o processo de fragmentação de hábitats aquáticos que podem ter levado a um isolamento das populações locais de peixes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Um ensaio de imunoadsorção enzimática (ELISA) baseado em antígeno bruto foi avaliado na detecção de anticorpos contra Babesia bigemina. A sensibilidade e a especificidade do teste foram de 98,0% e 99,0%, respectivamente. Concordando com a alta especificidade do teste, não foram verificadas reações cruzadas com soros de bezerros inoculados três vezes com 10(7) merozoítos de Babesia bovis. Com relação à comparação do ELISA com a imunofluorescência indireta (IFAT) na detecção de anticorpos contra B. bigemina em bezerros experimentalmente infectados com cinco isolados brasileiros geograficamente distintos deste hemoparasito, o IFAT foi capaz de detectar anticorpos um dia antes do ELISA na maioria dos soros dos animais. Houve uma boa concordância entre os resultados encontrados no ELISA e no IFAT com soros de bovinos de região de estabilidade enzoótica (k=0.61). No entanto, não houve concordância entre os testes sorológicos com soros de animais de área de instabilidade enzoótica (k=0.33). O ELISA foi empregado em um inquérito epidemiológico com 1.367 soros de quatro municípios do Pantanal de Mato Grosso do Sul e caracterizou esta região como uma área de estabilidade enzoótica, uma vez que as prevalências variaram de 87,7 a 98,9%. Dessa forma, este ELISA, que apresentou alta sensibilidade, especificidade e desempenho similar ao IFAT, pode ser utilizado no diagnóstico sorológico de B. bigemina.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Determinou-se o tempo necessário para a eliminação de Escherichia coli Shigatoxigênica (STEC) não-O157 em esterco bovino composto, obtido de fezes frescas de três vacas portadoras de cepas STEC não-O157 que apresentavam o gene stx 2. Foram utilizados dois sistemas de compostagem, o primeiro foi um buraco de 0,6m escavado no solo e o segundo um monte apresentando uma arquitetura piramidal com um metro de altura. Todos os dias, durante os primeiros 10 dias e a cada cinco dias durante um mês, uma amostra de três pontos diferentes dos dois sistemas de compostagem foram coletadas e semeadas para determinar a presença de E. coli e a presença do gene stx 2 nas células, sendo que em cada coleta a temperatura do sistema de compostagem foi determinada. Células de STEC não-O157 sobreviveram por 8, 25 e 30 dias nas temperaturas de 42, 40 e 38ºC, respectivamente, no sistema enterrado no solo, enquanto que no sistema de monte as células foram detectadas por 4, 4 e 7 dias em temperaturas de 65, 58 e 52ºC, respectivamente. A temperatura e os microrganismos presentes na microbiota do sistema de compostagem parecem ser os responsáveis pela eliminação do patógeno. Pode-se concluir que os dois sistemas de compostagem utilizados mostraram-se eficientes na eliminação de células de STEC. A aplicação de esterco após compostagem deve diminuir o risco de contaminação ambiental e a disseminação do patógeno.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Comparative genomic hybridization (CGH) was used to identify chromosomal imbalances in 19 samples of squamous cell carcinoma of the head and neck (HNSCC). The chromosome arms most often or er-represented were 3q (48%), 8q (42%), and 7p (32%); in many cases, these changes were observed at high copy number. Other commonly over-represented sites were 1q, 2q, 6p, 6q, and 18q. The most frequently under-represented segments were 3p and 22q. Loss of heterozygosity of two polymorphic microsatellite loci from chromosome 22 was observed in two tongue tumors, in agreement with the CGH analysis. Gains of 1q and 2q material were detected in patients exhibiting a clinical history of recurrence and/or metastasis followed by terminal disease. This association suggests that gain of 1q and 2q map be a new marker of head and neck tumors with a refractory clinical response. (C) 2000 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A tungsten carbide coating on the integrated platform of a transversely heated graphite atomizer (THGA((R))) used together with Pd(NO3)(2) + Mg(NO3)(2) as modifier is proposed for the direct determination of lead in vinegar by graphite furnace atomic absorption spectrometry. The optimized heating program (temperature, ramp time, hold time) of atomizer involved drying stage (110 degrees C, 5 s, 30 s; 130 degrees C, 5 s, 30 s), pyrolysis stage (1000 degrees C, 15 s, 30 s), atomization stage (1800 degrees C, 0 s, 5 s) and clean-out stage (2450 degrees C, I s, 3 s). For 10 mu L of vinegar delivered into the atomizer and calibration using working standard solutions (2.5-20.0 mu g L-1 Pb) in 0.2% (v/v) HNO3, analytical curve with good linear correlation (r = 0.9992) was established. The characteristic mass was 40 pg Pb and the lifetime of the tube was around 730 firings. The limit of detection (LOD) was 0.4 mu g L-1 and the relative standard deviations (n = 12) were typically <8% for a sample containing 25 pg L-1 Pb. Accuracy of the proposed method was checked after direct analysis of 23 vinegar samples. A paired t-test showed that results were in agreement at 95% confidence level with those obtained for acid-digested vinegar samples. The Pb levels varied from 2.8 to 32.4 pg L-1. Accuracy was also checked by means of addition/recovery tests and recovered values varied from 90% to 110%. Additionally, two certified reference materials were analyzed and results were in agreement with certified values at a 95% confidence level. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The influence of sample preparation strategy of vegetables on the electrothermal behaviour of Se without and with chemical modifiers such as Pd(NO3)(2), Pd(NO3)(2) + Mg(NO3)(2), Pd(NO3)(2) + Cd(NO3)(2), pre-reduced Pd, Mg(NO3)(2), and Ni(NO3)(2) was investigated. Acid digestates and slurries of vegetables (0.1% m/v in 1% m/v HNO3 + 0.005% v/v of Triton X-100) were used to prepare reference solutions or slurries. For 10 mul of each modifier tested, pyrolysis and atomization temperatures were evaluated using pyrolysis and atomization curves, respectively. Best conditions, such as thermal stability, signal profile, repeatability and sensitivity were attained using Pd(NO3)(2) as chemical modifier. The following heating program (temperature, ramp/hold time) of the graphite tube of the Varian SpectrAA-800Z atomic absorption spectrometer was used: dry step (85 degreesC, 5/0 s; 95 degreesC, 40/0 s; 120 degreesC, 10/.5 s); pyrolysis step (1400 degreesC, 10/3s); atomization step (2200 degreesC, 1/2 s); clean step (2600 degreesC, 2/0 s). This pyrolysis temperature is 800 degreesC higher than when measuring without any modifier. For 20 muL sample volume and 10 mug Pd(NO3)(2), analytical curves in the 3.0-30 mug Se 1(-1) range were obtained. The method was applied for Se determination in acid digestates and slurries of 10 vegetable samples and one standard reference material (rice flower) and results were in agreement at 95% confidence level. Recoveries varied from 89 to 95% for spiked samples. The lifetime of the graphite tube was ca. 250 firings and the relative standard deviations (n = 12) for a typical acid digestate and slurry containing 20 mug Se 1(-1) were 3.8% and 8.3%, respectively. The limits of detection were 2.0 mug Se 1(-1) and 0.6 mug Se 1(-1) Se for digestates and slurries, respectively. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Evaluation of rhythmic fluctuations cf physical and mental variables should be of special significance for the understanding of students' performance and setting the schedules of school activities. The present study investigated the pattern of diurnal variation in oral temperature, sleepiness and performance of a group of adolescents undergoing a daytime school schedule. Eighteen girls (mean age 16 years-old), who attended the same class from 0715h to 1645h, were tested on seven days. They measured their oral temperature, quantified their sleepiness level by means of a visual analogue scale, and completed the following tests: letter cancellation test, addition test, and a simple motor task. One-way ANOVA statistics for repeated measures was used in order to verify the effect of test time on oral temperature,sleepiness and performance. Possible correlations between the level of sleepiness and performance were investigated by means of Spearman rank correlation. The results revealed significant time of day effect cn all variables, except for the number of addition errors. Oral temperature values showed an increase from morning to afternoon. Letter cancellation, motor task and addition scores increased from early morning to late afternoon, showing rapid fluctuations throughout the day. Sleepiness level was negatively correlated with letter cancellation scores during the first three tests of the day. In agreement with other work, the diurnal variation of oral temperature, letter cancellation and addition test showed an improvement as the day progressed. Sleepiness, on the other hand, decreased throughout the day, with the highest level associated with the first test of the day, suggesting a circadian pattern of variation rather than a cumulative effect due to school activities.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A spectrophotometric method for the determination of dipyrone in pharmaceutical preparations is proposed. This method is based on selective oxidation of dipyrone, in the presence of sulphuric acid, splitting off formaldehyde which reacts with chromotropic acid, also in a sulphuric acid medium, producing a violet-red compound (lambda(max) 575 nm). Beer's law is obeyed in a concentration range of 0.57-5.7 ppm dipyrone with an excellent correlation coefficient (r = 0.9997). The results show a simple, accurate, selective and readily applied method to the determination of dipyrone in pharmaceutical products. The analytical results obtained for these products by the proposed method are in agreement with those of the Brazilian Pharmacopoeia procedure. No interference was observed from common excipients in formulations. Recoveries were within 98.7-101.2%, with standard deviations ranging from 0.2 to 1.7%. (C) 1999 Elsevier B.V. S.A. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method has been developed for the direct and simultaneous determination of As, Cu, Mn, Sb, and Se in drinking water by electrothermal atomic absorption spectrometry (ETAAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect back- ground correction. The thermal behavior of analytes during the pyrolysis and atomization stages was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3 and 1 + 1 (v/v) diluted water using mixtures of Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier, With 5 mug Pd + 3 mug Mg as the modifier, the pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1400degreesC and 2100degreesC, respectively, and 20 muL of the water sample (sample + 0.28 mol L-1 HNO3, 1 + 1, v/v), dispensed into the graphite tube, analytical curves were established ranging from 5.00 - 50.0 mug L-1 for As, Sb, Se; 10.0 - 100 mug L-1 for Cu; and 20.0 - 200 mug L-1 for Mn. The characteristic masses were around 39 pg As, 17 pg Cu, 60 pg Mn, 43 pg Sb, and 45 pg Se, and the lifetime of the tube was around 500 firings. The limits of detection (LOD) based on integrated absorbance (0.7 mug L-1 As, 0.2 mug L-1 Cu, 0.6 mug L-1 Mn, 0.3 mug L-1 Sb, 0.9 mug L-1 Se) exceeded the requirements of the Brazilian Food Regulations (decree # 310-ANVS from the Health Department), which established the maximum permissible level for As, Cu, Mn, Sb, and Se at 50 mug L-1, 1000 mug L-1, 2000 mug L-1, 5 mug L-1, and 50 mug L-1, respectively. The relative standard deviations (n = 12) were typically < 5.3% for As, < 0.5% for Cu, < 2.1% for Mn, < 11.7% for Sb, and < 9.2% for Se. The recoveries of As, Cu, Mn, Sb, and Se added to the mineral water samples varied from 102-111%, 91-107%, 92-109%, 89-97%, and 101-109%, respectively. Accuracy for the determination of As, Cu, Mu Sb and Se was checked using standard reference materials NIST SRM 1640 - Trace Elements in Natural Water, NIST SRM 1643d - Trace Elements in Water, and 10 mineral water samples. A paired t-test showed that the results were in agreement with the certified values of the standard reference materials at the 95% confidence level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method has been developed for the simultaneous determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by graphite furnace atomic absorption spectrometry (GFAAS) using a transversely heated graphite atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of analytes during the pyrolysis and atomization stages using the mixture Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3, and diluted ethanol (1 + 1, v/v) containing different nitric acid concentrations. With 5 rhog Pd + 3 mug Mg as the modifiers, pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1200 C and 2200degreesC respectively. For 20 muL of diluted sample (10 muL ethanol + 10 muL of 0.28 mol L-1 HNO3) dispensed into the graphite tube, analytical curves in the 2.0 - 50 mug L-1 Al, As, Cu, Fe, Mn, Ni ranges were established. The calculated characteristic masses were - 37 pg Al, 73 pg As, 31 pg Cu, 16 pg Fe, 9 pg Mn, and 44 pg Ni, and the lifetime of the tube was around 2 50 firings. The limits of detection (LOD) based on integrated absorbance were 1.2 mug L-1 Al, 2.5 mug L-1 As. 0.22 mug L-1 Cu, 1.6 L-1 Fe 0.20 mug L-1 Mn 1.1 mug L-1 Ni. The relatively standard deviations (n = 12) were less than or equal to 3%, less than or equal to 6%, less than or equal to 2%, less than or equal to 3.4%, less than or equal to 1.3%, and less than or equal to 2% for Al, As, Cu, Fe, Mn, and Ni, respectively, the recoveries of Al, As, Cu, Fe, Mn and Ni added to fuel ethanol samples varied from 77% to 112%, 92% to 114%, 104% to 113%, 73% to 116%, 91% to 122% and 93% to 116%, respectively. Accuracy was checked for Al, As, Cu, Fe, Mn, and Ni determination in 20 samples purchased at local gas stations in Araraquara city, Brazil. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained by single-element GFAAS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method has been developed for the direct determination of As in sugar by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (end-capped THGA) and longitudinal Zeeman-effect background correction. The thermal behavior of As during the pyrolysis and atomization steps was investigated in sugar solutions containing 0.2% (v/v) HNO3 using Pd, Ni, and a mixture of Pd + Mg as the chemical modifiers. For a 60-muL sugar solution, an aliquot of 8% (m/v) in 0.2% (v/v)HNO3 was dispensed into a pre-heated graphite tube at 70 degreesC. Linear analytical curves were obtained in the 0.25 - 1.50-mug L-1 As range. Using 5 mug Pd and a first pyrolysis step at 600 degreesC assisted by air during 40 s, the formation of a large amount of carbonaceous residue inside the atomizer was avoided. The characteristic mass was calculated as 24 pg As and the lifetime of the graphite tube was around 280 firings. The limit of detection (L.O.D.) based on integrated absorbance was 0.08 mug L-1 (4.8 pg As) and the typical relative standard deviation (n = 12) was 7% for a sugar solution containing 0.5 mug L-1. Recoveries of As added to sugar samples varied from 86 to 98%. The accuracy was checked in the direct analysis of eight sugar samples. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained for acid-digested sugar samples by GFAAS.