300 resultados para one way delay
Resumo:
Three procedures (line transect, point intercept and quadrat) for estimating abundance of macroscopic components of periphyton (macroalgae and bryophytes) were compared in two bedrock streams from southeastern Brazil on the basis of frequency and percent cover. In addition, two quadrat sizes (25 and 50 cm) were tested for best size. Samplings were all made within a 10 m length stream reach. Differences were tested by means of analysis of variance, ANOVA - one way, Student's t test and Chi-square test, whereas associations among them were evaluated by Pearson's r correlation coefficient. Values of frequency and percent cover varied among the different techniques and periphyton species in both sites but ANOVA, t and Chi-square tests revealed no significant difference (p<0.05) for percent cover in the two sites. No consistent pattern was observed for the different procedures between sites. Values for quadrat (25 and 50 cm) percent cover were positively correlated among distinct periphyton species. Significant differences for frequency were found in only one site. Quadrats of 50 cm produced the highest frequency values, whereas point intercept the lowest in both sites. In terms of spatial variation within the stream segment, significant differences were generally observed among all procedures, except between quadrats. As a rule, highly significant correlations for percent cover were found among the different techniques along the stream reach. The strongest relationships were found for quadrats with the other procedures, whereas the weakest between Line and point. Pros and cons of the three techniques are fully discussed.
Resumo:
Purpose: To assess the effect of the composite surface conditioning on the microtensile bond strength of a resin cement to a composite used for inlay/onlay restorations.Materials and Methods: Forty-two blocks (6 x 6 x 4 mm) of a microfilled composite (Vita VMLC) were produced and divided into 3 groups (N = 14) by composite surface conditioning methods: Gr1 - etching with 37% phosphoric acid, washing, drying, silanization; Gr2 - air abrasion with 50-Im Al203 particles, silanization; Gr3 - chairside tribochemiCal silica coating (CoJet System), silanization. Single-Bond (one-step adhesive) was applied on the conditioned surfaces and the two resin blocks treated with the same method were cemented using RelyX ARC (dual-curing resin cement). The specimens were stored for 7 days in water at 37 degrees C and then sectioned to produce nontrimmed beam samples, which were submitted to microtensile bond strength testing (mu TBS). For statistical analysis (one-way ANOVA and Tukey's test, = 0.05), the means of the beam samples from each luted specimen were calculated (n = 7).Results: mu TBS values (MPa) of Gr2 (62.0 +/- 3.9a) and Gr3 (60.5 +/- 7.9a) were statistically similar to each other and higher than Gr1 (38.2 +/- 8.9b). The analysis of the fractured surfaces revealed that all failures occurred at the adhesive zone.Conclusion: Conditioning methods with 50-Im Al203 or tribochemical silica coating allowed bonding between resin and composite that was statistically similar and stronger than conditioning with acid etching.
Resumo:
This article discusses the development of a test bench and a methodology for the study of composite resin abrasive wear. To evaluate the operation of the test bench and to compare the proposed methodology with other existing ones, a study was made of the five composites most commonly used by dentists.The one-way ANOVA method and the Tukey test were used to statistically analyze the results by multiple comparisons of the groups of resins tested. Using the proposed methodology, these resins were classified in an increasing order of abrasive wear strength, as follows: Charisma (the lowest abrasive wear strength), Tetric, TPH, Herculite and Z-100 (the highest abrasive wear strength) (P < 0.05). In comparison to other methodologies, the results of the proposed methodology presented the lowest coefficient of variation. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
The objective of this study was to determine intraocular pressure (IOP) and cardiac changes in normocapnic dogs maintained under controlled ventilation and anesthetized using sevoflurane or desflurane. Sixteen healthy adult mixed-breed dogs, seven males and nine females, weighing 10-15 kg were used. The dogs were randomly assigned to one of two groups composed of eight animals anesthetized with sevoflurane (SEVO) or desflurane (DESF). In both groups, anesthesia was induced with propofol (10 mg/kg), and neuromuscular blockade was achieved with rocuronium (0.6 mg/kg/h IV). No premedication was given. Ventilation was adjusted to maintain end-tidal carbon dioxide partial pressure at 35 mmHg. Anesthesia was maintained with 1.5 minimum alveolar concentration (MAC) of sevoflurane or desflurane. In both groups IOP was measured by applanation tonometry (Tono-Pen) before induction of anesthesia. IOP, mean arterial pressure (MAP), heart rate (HR), cardiac index (CI) and central venous pressure (CVP) were also measured 45 min after the beginning of inhalant anesthesia and then every 20 min for 60 min. A one-way repeated measures ANOVA was used to compare data within the same group and Student's t-test was used to assess differences between groups. P < 0.05 was considered statistically significant. Measurements showed normal IOP values in both groups, even though IOP increased significantly from baseline during the use of desflurane. IOP did not differ between groups. CI in the desflurane group was significantly greater than in the sevoflurane group. Sevoflurane and desflurane have no clinically significant effects on IOP, MAP, HR, CI or VCP in the dog.
Resumo:
Gold electrodes are widely used in electrochemistry and electroanalytical chemistry. The notable performance when used in stripping analysis of many ionic species and the extraordinary affinity of thio compounds for its surface make these electrodes very suitable for many applications. This paper reports a simple and novel way to construct gold electrodes (CDtrodes) using recordable CDs as the gold source. The nanometer thickness of the gold layer of recordable disks (50-100 mm) favors the construction of band nanoelectrodes with areas as small as 10(-6) cm(2). The plane surface can be easily used for the construction of conventional-sized gold electrodes for batch or now injection analysis or even to obtain electrodes as large as 100 cm(2). The low price of commercial recordable CDs allows a one way use. The evaluation and applicability of these electrodes in the form of nanoelectrodes, in batch and associated with flow cells, are illustrated in this paper.
Resumo:
Objective To assess the brachial plexus block in chickens by an axillary approach and using a peripheral nerve stimulator.Study design Prospective, randomized, double-blinded study.Animals Six, 84-week old, female chickens.Methods Midazolam (1 mg kg(-1)) and butorphanol (1 mg kg(-1)) were administered into the pectoralis muscle. Fifteen minutes later, the birds were positioned in lateral recumbency and following palpation of the anatomic landmarks, a catheter was inserted using an axillary approach to the brachial plexus. Lidocaine or bupivacaine (1 mL kg(-1)) was injected after plexus localization by the nerve stimulator. Sensory function was tested before and after blockade (carpus, radius/ulna, humerus and pectoralis muscle) in the blocked and unblocked wings. The latency to onset of motor and sensory block and the duration of sensory block were recorded. A Friedman nonparametric one-way repeated-measures ANOVA was used to compare scores from baseline values over time and to compare the differences between wings at each time point.Results A total of 18 blocks were performed with a success rate of 66.6% (12/18). The latency for motor block was 2.8 +/- 1.1 and 3.2 +/- 0.4 minutes for lidocaine and bupivacaine, respectively. The latencies for and durations of the sensory block were 6.0 +/- 2.5 and 64.0 +/- 18.0 and 7.8 +/- 5.8 and 91.6 +/- 61.7 minutes for lidocaine and bupivacaine, respectively. There was no statistical difference between these times for lidocaine or bupivacaine. Sensory function was not abolished in nonblocked wings.Conclusions and clinical relevance The brachial plexus block was an easy technique to perform but had a high failure rate. It might be useful for providing anesthesia or postoperative analgesia of the wing in chickens and exotic avian species that have similar wing anatomy.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: The aim of this study was to investigate the shear strength between distinct associations of different commercial composite resins and their fracture modes.Methods: Nine composite-composite associations (n = 90) were prepared for shear strength evaluation and separated into the following groups: Z/Z (Filtek Z250 UD + Filtek Z250 A2); Z/ D (Filtek Z250 UD + Durafill VS A2); Z/S (Filtek Z250 UD + Filtek Supreme YT); C/C (Charisma OA2 + Charisma A2); C/D (Charisma OA2 + Durafill VS A2); C/S (Charisma OA2 + Filtek Supreme YT); H/H (Herculite XRV B2D + Herculite XRV B2E); H/D (Herculite XRV B2D + Durafill VS A2); H/S (Herculite XRV B2D + Filtek Supreme YT). Shear tests were carried out using universal mechanical test equipment with a load of 200 kgf and speed of 0.5 mm/min. Ultimate shear strength data (MPa) from all tested groups were submitted to analysis of variance (one-way ANOVA) and the Tukey test. The fractured surfaces of the test samples were visually evaluated by binocular stereomicroscope at 20 times magnification. Fractures were classified as either adhesive or cohesive or mixed.Results: The highest ultimate shear strength observed for composite-composite associations was found for the groups: Z/Z, C/S, H/H, H/S, Z/S and C/C. Those associations containing the Durafill resin were weaker than the others.Conclusion: Microparticle RBC associations presented lower shear strength than hybrid and/or nanoparticle RBC associations, once the only significant difference was found when the Durafill resin was involved. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Considering the controversy in the literature regarding several aspects of temporomandibular dysfunction (TMD) in elderly populations and the absence of reliable data on elderly Brazilians in this field, this study consisted of an evaluation of TMD prevalence and the self-perception of oral health among institutionalised and community-dwelling elderly in Sao JosE dos Campos, Brazil.Two hundred and fifteen community-dwelling and 185 institutionalised elderly people were evaluated by the Helkimo anamnestic (Ai) and clinical dysfunction (Di) indices and answered a questionnaire using the Geriatric Oral Health Assessment Index (GOHAI).The major prevalence of TMD symptoms was for the Ai0 (symptom-free) group (69.5%), while the major prevalence of clinical signs was for the DiI (mild) group (56%). Women presented a higher AiII classification than men (chi(2) test, p = 0.049). Community-dwelling elderly presented a significantly lower Ai0 classification than the institutionalised ones (Two ratios equality test, p < 0.001). There was no relationship between the institutionalised status and the clinical dysfunction index for Di0 and DiIII classification (Two ratios equality test, p = 0.194 and 0.535 respectively). The institutionalised elderly presented greater (One-way anova = 0.005) self-perception of oral health (33.45) than did the community-dwelling group (32.66). There were only weak Pearson's correlations among the anamnestic (-33.0%) or clinical (-14.7%) findings by the TMD and GOHAI indices. Symptom-free (Ai0) institutionalised elderly presented better scores in all GOHAI dimensions and elderly representing an absence of clinical TMD signs (Di0) presented higher GOHAI physical dimension scores in both groups.The prevalence of TMD symptoms among this sample of elderly individuals was relatively low, self-perception of oral health was reasonable and a weak, inverse correlation was found between TMD signs and symptoms and elderly self-perception of oral health measured by the GOHAI index.
Resumo:
Objective To evaluate the cardiorespiratory and behavioural effects of epidural xylazine (XYL) or clonidine (CLO) in horses.Study design Blinded, randomized experimental study.Twelve healthy Arabian yearling horses weighing 117-204 kg were randomly allocated into two groups: XYL (n = 6) and CLO (n = 6).Methods An epidural catheter was inserted and a facial arterial catheter was placed and the next day the horses were restrained in stocks. Baseline values for heart (HR) and respiratory (RR) rates, arterial pressure and behavioural responses were evaluated before (TO) and 10, 20, 30, 45, 60, 90 and 120 minutes after epidural injection (T10-T120). The horses received 0.2 mg kg(-1) of XYL or 5 mu g kg(-1) CLO; adjusted to (3.4 + (body weight in kg x 0.013) mL with saline. Data were analysed by the Kolmogorov-Smirnov test, one-way ANOVA with repeated measures, and one-way ANOVA followed by a Student-Newman-Keuls test or Fisher's exact test, as necessary. Significance was set at p <= 0.05.Results Sedation and ataxia were seen at T10, persisting until T120 in four and three horses, respectively, in XYL and all horses in CLO respectively. Two XYL and one CLO horses became recumbent at T45 and T25 respectively. Penile prolapse occurred in four of five males at T30 and T45, in the XYL and CLO groups, respectively, resolving by T120. Tail relaxation was present from T10 to T120 in all horses in XYL and in four horses in CLO. Head drop was observed from T20 to T60 and from T10 to T120 in XYL and CLO respectively. Respiratory rate decreased significantly only at T45 in the CLO group. Heart rate and arterial blood pressure remained stable.Conclusions and clinical relevance Epidural CLO and XYL produce similar cardiorespiratory and behavioural changes but neither would be safe to use clinically at the doses used in this study.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Several studies have shown a reduction in enamel bond strengths when the bonding procedure is carried out immediately after vital bleaching with peroxides. This reduction in bond strengths has become a concern in cosmetic dentistry with the introduction of new in-office and waiting-room bleaching techniques. The aim of this in vitro study was to evaluate the effect of three bleaching regimens: 35% hydrogen peroxide (HP), 35% carbamide peroxide (CP), and 10% CP, on dentin bond strengths. Materials and Methods: One hundred and twenty fresh bovine incisors were used in this study. The labial surface of each tooth was ground flat to expose dentin and was subsequently polished with 600-grit wet silicon carbide paper. The remaining dentin thickness was monitored and kept at an average of 2 mm. The teeth were randomly assigned to four bleaching regimens (n = 30): (A) control, no bleaching treatment; (B) 35% HP for 30 minutes; (C) 35% CP for 30 minutes; and (D) 10% CP for 6 hours. For each group, half of the specimens (n = 15) were bonded with Single Bond/Z100 immediately after the bleaching treatment, whereas the other half was bonded after the specimens were stored for 1 week in artificial saliva at 37°C. The specimens were fractured in shear using an Instron machine. Results: For the groups bonded immediately after bleaching, one-way analysis of variance (ANOVA) followed by the Duncan's post hoc test revealed a statistically significant reduction in bond strengths in a range from 71% to 76%. For the groups bonded at 1 week, one-way ANOVA showed that group B (35% HP for 30 min) resulted in the highest bond strengths, whereas 10% CP resulted in the lowest bond strengths. Student's t-test showed that delayed bonding resulted in a significant increase in bond strengths for groups B (35% HP) and C (35% CP); whereas the group bleached with 10% CP (group D) remained in the same range obtained for immediate bonding. Storage in artificial saliva also affected the control group, reducing its bond strengths to 53% of the original. ©2000 BC Decker Inc.
Resumo:
The relative contribution of migration of Rhizoctonia solani anastomosis group 3 (AG-3) on infested potato seed tubers originating from production areas in Canada, Maine, and Wisconsin (source population) to the genetic diversity and structure of populations of R. solani AG-3 in North Carolina (NC) soil (recipient population) was examined. The frequency of alleles detected by multilocus polymerase chain reaction-restriction fragment length polymorphisms, heterozygosity at individual loci, and gametic phase disequilibrium between all pairs of loci were determined for subpopulations of R. solani AG-3 from eight sources of potato seed tubers and from five soils in NC. Analysis of molecular variation revealed little variation between seed source and NC recipient soil populations or between subpopulations within each region. Analysis of population data with a Bayesian-based statistical method previously developed for detecting migration in human populations suggested that six multilocus genotypes from the NC soil population had a statistically significant probability of being migrants from the northern source population. The one-way (unidirectional) migration of genotypes of R. solani AG-3 into NC on infested potato seed tubers from Canada, Maine, and Wisconsin provides a plausible explanation for the lack of genetic subdivision (differentiation) between populations of the pathogen in NC soils or between the northern source and the NC recipient soil populations.