225 resultados para maximum loading
Resumo:
Purpose: Existing composite restorations on teeth are often remade prior to the cementation of fixed dental prostheses. The aim of this study was to evaluate the effect of static and cyclic loading on ceramic laminate veneers adhered to aged resin composite restorations.Materials and Methods: Eighty sound maxillary incisors were collected and randomly divided into four groups: group 1: control group, no restorations; group 2: two Class III restorations; group 3: two Class IV restorations; group 4: complete composite substrate. Standard composite restorations were made using a microhybrid resin composite (Anterior Shine). Restored teeth were subjected to thermocycling (6000 cycles). Window preparations were made on the labial surface of the teeth for ceramic laminate fabrication (Empress II). Teeth were conditioned using an etch-and-rinse system. Existing composite restorations representing the aged composites were silica coated (CoJet) and silanized (ESPE-Sil). Ceramic laminates were cemented using a bis-GMA-based cement (Variolink Veneer). The specimens were randomly divided into two groups and were subjected to either static (groups 1a, 2a, 3a, 4a) or cyclic loading (groups 1b, 2b, 3b, 4b). Failure type and location after loading were classified. Data were analyzed using one-way ANOVA and Tukey's test.Results: Significantly higher fracture strength was obtained in group 4 (330 +/- 81 N) compared to the controls in group 1 (179 +/- 120 N) (one-way ANOVA, p < 0.05). Group lb survived a lower mean number of cyclic loads (672,820 cycles) than teeth of groups 2b to 4b (846x10(3) to 873x10(3) cycles). Failure type evaluation after the fracture test showed predominantly adhesive failures between dentin and cement, but after cyclic loading, more cohesive fractures in the ceramic were seen.Conclusion: Ceramic laminate veneers bonded to conditioned aged composite restorations provided favorable results. Surface conditioning of existing restorations may eliminate the necessity of removing aged composite restorations.
Resumo:
Objectives. This study evaluated the effect of thermal- and mechanical-cycling on the shear bond strength of three low-fusing glassy matrix dental ceramics to commercial pure titanium (cpTi) when compared to conventional feldspathic ceramic fused to gold alloy.Methods. Metallic frameworks (diameter: 5 min, thickness: 4 mm) (N = 96, n = 12 per group) were cast in cpTi and gold alloy, airborne particle abraded with 150 mu m aluminum oxide. Low-fusing glassy matrix ceramics and a conventional feldspathic ceramic were fired onto the alloys (thickness: 4mm). Four experimental groups were formed; Gr1 (control group): Vita Omega 900-Au-Pd alloy; Gr2: Ticeram-cpTi; Gr3: Super Porcelain Ti-22-cpTi and G4: Vita Titankeramik-cpTi. While half of the specimens from each ceramic-metal combination were randomly tested without aging (water storage at 37 C for 24h only), the other half were first thermocycled (6000 cycles, between 5 and 55 C, dwell time: 13 s) and then mechanically loaded (20,000 cycles under SON load, immersion in distilled water at 37 C). The ceramic-alloy interfaces were loaded under shear in a universal test machine (cross-head speed: 0.5 mm/min) until failure occur-red. Failure types were noted and the interfaces of the representative fractured specimens from each group were examined with stereo microscope and scanning electron microscope (SEM). in an additional study (N = 16, n = 2 per group), energy dispersive X-ray spectroscopy (EDS) analysis was performed from ceramic-alloy interfaces. Data were analyzed using ANOVA and Tukey's test.Results. Both ceramic-metal combinations (p < 0.001) and aging conditions (p < 0,001) significantly affected the mean bond strength values. Thermal- and mechanical-cycling decreased the bond strength (MPa) results significantly for Gr3 (33.4 +/- 4.2) and Gr4 (32.1 +/- 4.8) when compared to the non-aged groups (42.9 +/- 8.9, 42.4 +/- 5.2, respectively). Gr1 was not affected significantly from aging conditions (61.3 +/- 8.4 for control, 60.7 +/- 13.7 after aging) (p > 0.05). Stereomicroscope images showed exclusively adhesive failure types at the opaque ceramic-cpTi interfacial zone with no presence of ceramic on the substrate surface but with a visible dark titanium oxide layer in Groups 2-4 except Gr1 where remnants of bonder ceramic was visible. EDS analysis from the interfacial zone for cpTi-ceramic groups showed predominantly 34.5-85.1% O(2) followed by 1.1-36.7% Aland 0-36.3% Si except for Super Porcelain Ti-22 where a small quantity of Ba (1.4-8.3%), S (0.7%) and Sn (35.3%) was found. In the Au-Pd alloy-ceramic interface, 56.4-69.9% O(2) followed by 15.6-26.2% Si, 3.9-10.9% K, 2.8-6% Na, 4.4-9.6% Al and 0-0.04% Mg was observed.Significance. After thermal-cycling for 6000 times and mechanical-cycling for 20,000 times, Triceram-cpTi combination presented the least decrease among other ceramic-alloy combinations when compared to the mean bond strength results with Au-Pd alloy-Vita Omega 900 combination. (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber posts and varying quantities of coronal dentin. Sixty freshly extracted upper canines were randomly divided into groups of 10 teeth each. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis. Data were analyzed by 1-way analysis of variance and Tukey test (alpha = .05). Significant differences (P < .001) were found among the mean fracture forces of the test groups (positive control, 0 mm, 1 mm, 2 mm, 3 mm, and negative control groups: 1022.82 N, 1008.22 N, 1292.52 N, 1289.19 N, 1255.38 N, and 1582.11, respectively). These results suggested that the amount of coronal dentin did not significantly increase the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber post and composite resin core. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:e52-e57)
Resumo:
A performance comparison between a recently proposed novel technique known as fast orthogonal frequency-division multiplexing (FOFDM) and conventional orthogonal frequency-division multiplexing (OFDM) is undertaken over unamplified, intensity-modulated, and direct-detected directly modulated laser-based optical signals. Key transceiver parameters, such as the maximum achievable transmission capacity and the digital-to-analog/analog-to-digital converter (DAC/ADC) effects are explored thoroughly. It is shown that, similarly to conventional OFDM, the least complex and bandwidth efficient FOFDM can support up to similar to 20 Gb/s over 500 m worst-case multimode fiber (MMF) links having 3 dB effective bandwidths of similar to 200 MHz X km. For compensation of the DAC/ADC roll-off, a power-loading (PL) algorithm is adopted, leading to an FOFDM system improvement of similar to 4 dB. FOFDM and conventional OFDM give similar optimum DAC/ADC parameters over 500 m worst-case MMF, while over 50 km single-mode fiber a maximum deviation of only similar to 1 dB in clipping ratio is observed due to the imperfect chromatic dispersion compensation caused by one-tap equalizers.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Plantas dos capins braquiaria brachiaria decumbens Stapf (Prain) , quicuio da Amazonia, (Brachiaria humidicola (Rendle) Schweickerdt), pangola (Digitaria decumbens Stent), jaraguá (Hyphrrhenia rufa (Ness) Stapf), gordura (Melinis minutiflora Pal de Beauv), colonião (Panicum maximum Jacq) e napier (Pennisetwn purpure um Schum) foram cultivadas em solução nutritiva completa contendo, 0,12; 0,48; 1,94; 7,75 e 31,00 mg de fósforo por litro, com o objetivo de determinar os níveis críticos internos e externos de fosforo, e avaliar a eficiência com que absorvem e utilizam o fósforo. Aos setenta e cinco dias as plantas foram coletadas, separadas em caules, folhas, bainhas e raízes. Após secagem a 80ºC, as amostras foram pesadas e analisadas para fósforo na matéria seca. Curvas representativas do peso da matéria seca e da concentração de fósforo na matéria seca em função dos níveis de fosforo da solução nutritiva foram obtidas a partir de dados calculados de equações de regressão. Verificou-se que: - As espécies diferiram quanto à necessidade externa de fósforo, sendo B. humidicola e H. rufa as menos exigentes. Seguiram-se em ordem crescente B. decumbens, M. minutiflora, P. maximum, P. purpureum e D. decumbens. - Os níveis críticos internos de fósforo variaram entre as espécies, sendo maior em D. decumbens (0,38%) que nas demais. Seguiram-se em ordem decrescente B. decumbens (0,32%), B. humidioola (0,26%), M. minutiflora (0,24%), P. maximum (o,24%) e P. purpureum (0,20%). - A eficiência de absorção e utilização, do fósforo foi maior para B. humidicola. Seguiram-se em ordem decrescente P. purpureum, P. maximum, D. decumbens , B. decumbens e M. minutiflora.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Foram avaliadas as interações entre o glyphosate e o espalhante adesionante correspondente ao condensado de alcoolfenóis com óxido de eteno e sulfonados orgânicos quanto à redução de tensão superficial e ao controle de Panicum maximum e Brachiaria decumbens. Os produtos comerciais apresentavam 360 g e.a./l e 466 g i.a./l, respectivamente. O herbicida reduziu o efeito do espalhante sobre a tensão superficial. Na concentração de 0,1% de p.c., o espalhante maximizou o controle das duas espécies pelo glyphosate. P. maximum mostrou-se menos sensível ao glyphosate que B. decumbens, exigindo doses 24,05% superiores.
Resumo:
Avaliou-se o efeito do nitrogênio no sistema radicular da espécie Panicum maximum Jacq. cv. IPR-86 Milênio, sob pastejo. As doses de N utilizadas foram 0; 150; 300 e 450 kg/ha.ano. As densidades de raízes no pré-pastejo foram avaliadas no quinto ano de aplicação de N, em três profundidades (0-10; 10-20 e 20-40 cm), com crescimento aos 7; 14; 21 e 35 dias após o pastejo. O método de pastejo utilizado foi o de lotação rotacionada. Os valores máximos de densidades de comprimento e de massa das raízes no pré e no pós-pastejo foram obtidos nas doses de N de 204; 206; 192 e 197 kg/ha, respectivamente. Nas doses de N de 0, 150 e 300 kg/ha, o crescimento das raízes (em densidade de comprimento) aumentou, em média, até 29 dias após o pastejo, enquanto, na dose 450 kg/ha, o aumento foi linear. Independentemente da dose de N, 60 a 25% do sistema radicular do cultivar IPR-86 Milênio concentrou-se nas camadas de 0-10 e 10-20 cm de profundidade, respectivamente.
Resumo:
This work was carried out at FCAV-UNESP, Campus of Jaboticabal, Brazil, to study the effects of nitrogen fertilization (0 and 50 kg N/ha/cut), three sucessive periods of growth (December 21st 1987, January 25th 1988 and February 29th 1988)) and three cutting ages (28, 35 and 42 days) on composition in crude protein and in vitro dry matter digestibility of two cultivars of Panicum maximum Jacq. i.e., Coloniao and Tobiata. Plants were harvested in five vertical layers above soil level (0-20, 20-40, 40-60, 60-80 and over 80 cm). The samples were divided in: green leaves, green stems and dry material. Generally, values of in vitro dry matter digestibility and the levels of crude protein of both cultivars were greater in the higher layers of the vegetation, with a decrease, however, for the other layers and more advanced phases of plants development, mainly with no N fertilization.
Resumo:
The bond strength of composite resins (CRs) to dentin is influenced by the interfacial microstructure of the hybrid layer (HL) and the resin tags (TAG). The contemporary self-etching primer adhesive systems overcame the inconvenient of the etch-and-rinse protocol. Studies, however, have demonstrated that HL thickness and TAG length vary according to the wetting time and additional use of acid-etching prior to self-etching primers. This study investigated the localized stress distribution in the HL and the dentin/adhesive interface. Two HL thicknesses (3 or 6 mu m), two TAG lengths (13 or 17 mu m) and two loading conditions (perpendicular and oblique-25 degrees) were investigated by the finite element (FE) analysis. Five two-dimensional FE models (M) of a dentin specimen restored with CR (38 x 64 mu m) were constructed: M1 - no HL and no TAG; M2 - 3 mu m of HL and 13 mu m of TAG; M3 - 3 mu m of HL and 17 mu m of TAG; M4 - 6 mu m of HL and 13 mu m of TAG; and M5 - 6 mu m of HL and 17 mu m of TAG. Two distributed loadings (L) (20N) were applied on CR surface: L1 - perpendicular, and L2 - oblique (25 degrees). Fixed interfacial conditions were assigned on the border of the dentin specimen. Ansys 10.0 (Ansys (R), Houston, PA, USA) software was used to calculate the stress fields. The peak of von Mises (sigma(vM)) and maximum principal stress (sigma(max)) was higher in L2 than in L1. Microstructures (HL and TAG) had no effect on local stresses for L1. Decreasing HL decreased sigma(vM) and sigma(max) in all structures for L2, but the TAG length had influence only on the peributular dentin. The thickness of HL had more influence on the sigma(vM) and sigma(max) than TAG length. The peritubular dentin and its adjacent structures showed the highest sigma(vM) and sigma(max), mainly in the oblique loading.
Resumo:
In order to compare the in situ degradability of tanzania grass samples obtained as by extrusa or hand plucked, three ruminal fistulated cows were used in a completely randomized block design with split-plot scheme. Five grams of extrusa or hand harvested grasses were placed in nylon bags rumen incubated during 3, 6, 12, 24, 48, 96 and 120 hours. The degradability of DM, CP, NDF and ADF were, in this sequence, 62.59, 80.88, 50.73 and 46.65%, for hand-harvested grass; and 79.53, 90.97, 71.21 and 65.68%, for extrusa. In situ degradability data of hand harvested samples were not reliable.