260 resultados para fetal membranes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrated bacterial cellulose (BC) membranes obtained from cultures of Acetobacter xylinum were used in the preparation of silver nanoparticles containing cellulose membranes. In situ preparation of Ag nanoparticles was achieved from the hydrolytic decomposition of silver triethanolamine (TEA) complexes. Scanning electron microscopy (SEM) images and X-ray diffraction (XRD) patterns both lead to the observation of spherical metallic silver particles with mean diameter of 8 nm well adsorbed onto the BC fibriles. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotina bacteriológica do conteúdo vaginal e cervical de 22 mulheres com histórico de aborto recente ou ruptura precoce das membranas foi realizada. Chlamydia trachomatis, Streptococcus pyogenes, Streptococcus agalactiae, Candida sp e Gardnerella vaginalis foram isolados em 54,5% (12) das pacientes. Apesar de Ureaplasma urealyticum ter sido frequentemente encontrado (45,5%), somente em 5 das 22 mulheres foi o único microrganismo presente nos materiais analisados. Esses resultados chamam a atenção para a importância de investigação quantitativa bem como qualitativa da microbiota genital em gestantes, tendo em vista ter consequências na gestação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilizaram-se 13 cabras gestantes da raça Saanen, para estudo das características da gestação a partir do 60º dia, segundo as técnicas de fetometria e avaliação morfológica fetal, utilizando-se ultra-sonografia em modo-B. Analisaram-se: diâmetro orbital (DO), diâmetro interorbital (DIO), diâmetro biorbital (DBO), diâmetro biparietal (DBP), comprimento do fêmur (CF), comprimento da tíbia (CT), comprimento do rádio (CR), diâmetro do tórax (DT), diâmetro abdominal transversal (DAT), diâmetro abdominal anteroposterior (DAP), diâmetro occípito-frontal (DOF), diâmetro transversal renal (RIMT), diâmetro longitudinal renal (RIML), comprimento da escápula (ESC), comprimento do metacarpo (MEC), medida da pelve (COX) e comprimento do úmero (CU). As médias dos valores achados foram correlacionadas com a idade fetal. As equações de regressão inversa foram criadas para cada parâmetro, sendo que DBP (R²=0,93), CF (R²=0,95), CU (R²=0,96), do (R²= 0,84) e DAT (R²= 0,91) foram as variáveis de melhor correlação estatística, cuja equação pode ser representada pela fórmula: idade fetal = 34,5 + 4,8DBP + 9,9 CF - 7,5 CU - 2,3 do + 6,1 DAT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to standardize the analysis of zinc binding on human red blood cell (RBC) membranes in 20 normal adults. The displacement studies revealed that at the maximal stable zinc concentration tested (600 muM), 57% (mean) of the bound Zn-65 was displaced and to displace half maximal Zn-65, the stable zinc concentration was 300 muM. Scatchard plots revealed two classes of binding sites for zinc on RBC membranes: one with higher affinity, Kd = 1.20 x 10(-5) M (site I), and the other with lower affinity, Kd = 2.77 x 10(-4) M (site II). Binding sites occupancy was 97% means and 58.5% means for sites I and 11, respectively. The displacement was affected by temperature, membrane protein concentration, freezing, thawing, and dialysis. Other metal cations, including Co++, Fe++, and Mn++, had very little effect on Zn-65 displacement, in contrast copper displaced Zn-65 from its binding sites on RBC membranes. Zinc binding to RBC membranes was rapid and readily reversible in a dynamic equilibrium with its binding sites. It is anticipated that this method will be applicable to studies of a wide variety of diseases specifically related to zinc metabolism in humans as well as in animals. (C) 1994 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work describes the biocompatibility and biodegradation studies of anionic collagen membranes casted form collagen gels collagen, that were selective hydrolyzed at the carboxyamide groups, as a function of the degree of cross-links induced by glutaraldehyde. Independently from the degree of cross-links, all membranes studied were characterized by a similar inflammatory response, inversely dependent on glutaraldehyde reaction time, that decreased from the time of the implant. Cell alterations, mineralization or contact necrosis were not observed in any of the membranes studied. Rates for membrane tissue biodegradation were directly related to glutaraldehyde reaction time, and ranged from 30 to periods longer than 60 days, associated with good biocompatibility. Although other properties must be considered, their use in the treatment of periodontal diseases, the biological behavior observed with the 8 h GA cross-linked membrane suggests that, anionic collagen membrane described in this work may be of potential use, not only in association with guided tissue regeneration technique for periodontal tissue reconstruction, but also in other collagen biomaterial applications where controlled biodegradability is required. (C) 1998 Published by Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the proposal was to study the presence of immunoglobulin A (IgA) in the chorioamniotic membrane of healthy postpartum women with premature rupture of the chorioamniotic membrane (FROM). Method: A single radial immunodiffusion technique was used to quantify the IgA in the chorioamniotic membrane tissues. Results: the level of IgA was approximately 10 times higher in patients whose membranes had been ruptured for > 10 h (24.58 mg/dl). These results were compared with those of a previously published study where the mean of amount of IgA was 2.52 mg/dl in membranes of patients with rupture < 10 h. Our results show that IgA began to rise after 10-15 h following rupture. Conclusion: Although more studies need to be performed our data indicate that the increasing IgA in our patients after 10 h of latency probably represents the beginning of an ascending colonization of bacteria which could be the source of future infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The colloidal route of the sol-gel process was used to prepare supported SnO2 membranes. The influence of the sol and monoelectrolyte concentrations on the formation of the gel layer by sol-casting on the top of macroporous alpha-Al2O3 support was described. The stability of the colloidal suspension as a function of the concentrations was analyzed from creep-recovery measurements. The calcined supported membranes were characterized by nitrogen adsorption-desorption isotherms and scanning electron microscopy. The set of results show that homogeneous membrane layers containing the smallest quantity of cracks are formed in a critical interval of sol (1.01 less than or equal to[SnO2]less than or equal to 1.4 M) and electrolyte (2.O less than or equal to[Cl-]less than or equal to 4.0 mM) concentrations. The samples prepared from concentrated suspensions present a lot of interconnected cracks which favors the peeling of the coated layer. The membranes have pores of average diameter of about 1 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a piezoelectric composite membranes were developed for charge generator to promoter bone regeneration on defects sites. Is known that the osteogenesis process is induced by interactions between biological mechanisms and electrical phenomena. The membranes were prepared by mixing Barium Titanate (BT) powders and PVDF-TrFE (PVDF:TrFE = 60:40 mol%) on dimethylformamide medium. This precursor solution was dried and crystallized at 100degreesC for 12 hours. Composites membranes were obtained by following methods: solvent casting (SC), spincoating (SP), solvent extraction by water addition (WS) and hot pressing (HP).The microstructural analysis performed by SEM showed connectivity type 3-0 and 3-1 with high homogeneity for samples of ceramic volume fraction major than 0.50. Powder agglomerates within the polymer matrix was evidenced were observed for composites with the BT volume fraction major than 40%. The composite of ceramic fraction of 0.55 presented the best values of remanent polarization (similar to33 muC/cm(2)), but the flexibility of these composites with the larger ceramic fraction was significantly affected.For in vivo evaluation PVDF-TrFE/BT 90/10 membranes with 3cm larger were longitudinally implanted under tibiae of male rabbit. After 21 days the animals were sacrificed. By histological analyses were observed neo formed bone with a high mitotic activity. In the interface bone-membrane was evidenced a pronounced callus formation. These results encourage further applications of these membranes in bone-repair process.