96 resultados para equação universal de perda de solo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Soil tillage is one of the agricultural practices that may contribute to increase the loss of carbon through emission of CO2 (FCO2). The aim of this study was to investigate the effect of three soil tillage systems on FCO2, soil temperature and soil moisture in a sugarcane area under reform. The experimental area consisted of three tillage plots: conventional tillage (CT), conventional subsoiling (CS), and localized subsoiling (LS). FCO2, soil temperature and soil moisture were measured over a period of 17 days. FCO2 showed the highest value in CT (0.75 g CO2 m(-2) h(-1)). Soil temperature presented no significant difference (p > 0.05) between LS (26.2 degrees C) and CS (25.9 degrees C). Soil moisture was higher in LS (24%), followed by CS (21.8%) and CT (18.3%). A significant correlation (r = -0.71; p < 0.05) between FCO2 and soil temperature was observed only in CT. The conventional tillage presented a total emission (2,864.3 kg CO2 ha(-1)) higher than the emissions observed in CS (1,970.9 kg CO2 ha(-1)) and LS (1,707.7 kg CO2 ha(-1)). The conversion from CT to LS decreased soil CO2 emissions, reducing the contribution of agriculture in increasing the concentration of greenhouse gases in the atmosphere.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the pumping pipelines the located load losses are very important since they have direct influence on hydraulic design of an irrigation system, especially regarding the concentric reducers used in the distribution lines. Hence this work was conducted in the Laboratório de Hidráulica do Centro Federal de Educação Tecnológica de Uberaba. We analyzed 03 concentric reducers PVC 75 x 50 mm, 50 mm and 35 x 35 x 1 "operating at different flow rates. The performance of the tests with the variation of flow in every situation possible to obtain equations to estimate the loss. The equation models presented a high setting, thus enabling the determination of the localized head loss in a situation closer to field reality. For the reduction of 75 x 50 x 35 mm and 50 mm at a flow rate 16.97 m³ h-1 the pressure drop reduction was obtained respectively 0.9263 and 2.7408 mca. To the reduction of 35 x 1 "at a flow rate of 6.02 m³ h-1 was obtained 2.9304 mca pressure drop reduction. The located losses produced by these reductions are relatively high and should be considered with great discretion in hydraulic design of the irrigation system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)