189 resultados para computed tomography images


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The lunulae, ossification of the meniscus, are found in several species of rodents. Some studies suggest that the lunulae may be anatomical features, because there are not any pathological findings in microscopy. The objective of this study was to investigate the presence of lunulae in capybara knees, the world's largest rodent, by simple tomographic scans and three-dimensional reconstruction. For this purpose, we used two adult capybaras, in which both knees were evaluated. The lunulae were visualized with three-dimensional images, and revealed a total of two cranially. With the presence of lunulae confirmed, the capybara may be included in the group of rodents that have this structural feature, which can also contribute to the distinction between pathological processes and normal anatomic structures on imaging tests.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work aims to study the microstructure and mechanical properties of titanium alloys, widely used in the manufacture of orthopedic implants in order to compare a new manufacturing technology of implants, rapid prototyping in metals with conventional manufacturing processes. Rapid prototyping is being used in many areas of human knowledge to assist in the study and often in the manufacture of components for their own use. Nowadays with the advancement of software and equipment such as computed tomography and magnetic resonance imaging, we can reproduce any part of the human body in three-dimensional images with great perfection and it is used in the reproduction of implants, scaffolds, material aid and preparation in surgery. This work aims to do: A comparison between the microstructure of the alloy in the two manufacturing processes (prototyping and conventional), showing the grain size, the nature, form, quantity, and distribution of various ingredients or certain inclusions and study of mechanical properties of titanium in both cases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the recent years, the use of proton beams in radiotherapy has been an outstanding progress (SMITH, 2006). Up to now, computed tomography (CT) is a prerequisite for treatment planning in this kind of therapy because it provides the electron density distribution required for calculation of dose and the interval of doses. However, the use of CT images for proton treatment planning ignores fundamental differences in physical interaction processes between photons and protons and is, therefore, potentially inaccurate (SADROZINSKI, 2004). Proton CT (pCT) can in principle directly measure the density distribution needed in a patient for the dose distribution (SCHULTE, et al, 2004). One important problem that should be solved is the implementation of image reconstruction algorithms. In this sense, it is necessary to know how the presence of materials with different density and composition interfere in the energy deposition by ionization and coulomb excitation, during its trajectory. The study was conducted in two stages, was used in both the program SRIM (The Stopping and Range of Ions in Matter) to perform simulations of the interaction of proton beams with pencil beam type. In the first step we used the energies in the range of 100-250 MeV (ZIEGLER, 1999). The targets were set to 50 mm in length for the beam of 100 MeV, due to its interaction with the target, and short-range, and 70 mm for 150, 200 and 250 MeV The target was composed of liquid water and a layer of 6 mm cortical bone (ICRP). It were made 9 simulations varying the position of the heterogeneity of 5 mm. In the second step the energy of 250 MeV was taken out from the simulations, due to its greater energy and less interaction. The targets were diminished to 50 mm thick to standardize the simulations. The layer of bone was divided into two equal parts and both were put in the ends of the target... (Complete abstract click electronic access below)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The osteomas are benign rare neoplasms, generally asymptomatic which are characterized by the proliferation of a compact or spongy bone. When they are situated in the maxillofacial area, they affect mainly the mandible, the frontal bone and the paranasal sinus. We have described the case of a female caucasian patient who presented an increased volume in the posterior region of the oral vestibule on the left side. During the clinical examination an oral lesion was observed in the region of the left ramus of mandible. This lesion was motionless, consistent, and painless when palpated. In the image obtained from the computed tomography cone–beam (CBCT), we could observe an hyperdense, cylindrical region, with well defined borders, located in the medial surface of the left ramus of mandible, right below the mandibular notch. Based on clinical data and in the obtained images, we could confirm the presence of the peripheral osteoma in the left side of the ramus of mandible region.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The technology, through the advent of new equipments that allow imaging exams, has helped very much in the diagnosis and prognosis of diseases in Dentistry. The use of informatics, in general, in the manufacture of clinical reports is increasingly present in the dental offices. The legal validity of these systems is questioned, and is matter of discussion. This work makes considerations about Imageology or Diagnostic by image, a new area that is appearing on Dentistry. Among other exams, there are: digital radiography, tomography, computed tomography, artomography, magnetic resonance, computed cefalometry and ultra-sonography. It permits the professional to obtain a better diagnostic, and to the patient, the visualization of his problem and treatment. A survey on the possibilities of using informatics in Dentistry, particularly in Radiology, was also carried out, as well as the legal aspects, which are in accordance with the Law 8.935/94, what guarantees its practicability. Digital Certification is a mechanism that provides legal validity to documents and, as such, to radiographic images and others. It is a procedure that the dentist should take to ensure that he/she has safeguarded the judicial proofs that may be necessary in an eventual demand.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)