454 resultados para Séries de Tempo
Resumo:
Background and Objectives - Pulmonary aspiration of gastric content during induction of anesthesia for emergency surgical procedures is a serious complication; fast endotracheal intubation under these circumstances is of vital importance to secure the airways. Despite its numerous side effects, succinylcholine is used for this purpose. Rocuronium is the most recently introduced aminoesteroid neuromuscular blocking drug with short onset. The objective of this study was to compare the onset time and intubating conditions of rocuronium and succinylcholine. Methods - After informed consent, forty-five patients were randomly allocated into three groups of 15: Group I (GI) = succinylcholine 1 mg.kg-1; Group II (GII) = rocuronium 0.6 mg.kg-1; Group III (GIII) = rocuronium 0.9 mg.kg-1. Every patient was premedicated with midazolam 15 mg per os and induction of anesthesia was made with fentanyl 10 μg.kg-1 and etomidate 0.3 mg.kg-1. The neuromuscular block was monitored with the TOP-Guard neuromuscular transmission monitor. The TOP-Guard neuromuscular monitor uses an accelerometer to measure the response to nerve stimulation. The stimulating electrodes were placed close to the course of the ulnar nerve at the wrist. The onset time was considered as the time between the end of neuromuscular drug injection and the twitch height (T1) decrease to 10%. Heart rate and arterial blood pressure were registered at 6 moments before and after induction of anesthesia. Results - The onset time results were: Group I, 71 s; Group II, 120 s and Group III, 70 s or GI = GIII < GII (F = 8.862; p < 0.01). There were 43 patients exhibiting excellent intubating conditions and 2 with good intubating conditions. Heart rate and arterial blood pressure showed alterations due to induction of anesthesia and intubation. Conclusions - Rocuronium 0.9 mg.kg-1 can be used in rapid sequence induction because it has a short onset time which is similar to that of succnylcholine. It is likely that rocuronium would be a good indication in patients with high intracranial pressure, burns and neuromuscular diseases.
Resumo:
This work presents an experimental study on the life of abrasive discs in cut-off type operations with two conditions of cutting speed. The cutting time is shown with a comparative analysis of the cutting speed.
Resumo:
Background and Objectives - Sevoflurane is an inhalational anesthetic drug with low blood/gas solubility providing fast anesthesia induction and emergence. Its ability to maintain cardiovascular stability makes it ideal for pediatric anesthesia. The aim of this study was to evaluate hemodynamic stability, consumption of inhalational anesthetics and emergence time in children with and without premedication (midazolam or clonidine) anesthetized with sevoflurane titrated according to BIS monitoring. Methods - Participated in this study 30 patients aged 2 to 12 years, physical status ASA I, undergoing elective surgeries who were divided into 3 groups: G1 - without premedication, G2 - 0.5 mg.kg-1 oral midazolam, G3 - 4 μg.kg-1 oral clonidine 60 minutes before surgery. All patients received 30 μg.kg-1 alfentanil, 3 mg.kg-1 propofol, 0.5 mg.kg-1 atracurium, sevoflurane in different concentrations monitored by BIS (values close to 60) and N2O in a non rebreathing system. Systolic and diastolic blood pressure, heart rate, expired sevoflurane concentration (EC), sevoflurane consumption (ml.min-1) and emergence time were evaluated. Emergence time was defined as time elapsed between the end of anesthesia and patients' spontaneous movements trying to extubate themselves, crying and opening eyes and mouth. Results - There were no differences among groups as to systolic and diastolic blood pressure, EC, sevoflurane consumption and emergence time. Heart rate was lower in G3 group. Conclusions - Sevoflurane has provided hemodynamic stability. Premedication with clonidine and midazolam did not influence emergence time, inhaled anesthetic consumption or maintenance of anesthesia with sevoflurane. Anesthesia duration has also not influenced emergence time. Hypnosis monitoring was important for balancing anesthetic levels and this might have been responsible for the similarity of emergence times for all studied groups.
Resumo:
Background and Objectives - Successful cadaver kidney transplantation relies on a fast procedure. Patients with chronic renal failure may present with a delayed gastric emptying making it critical a fast tracheal intubation and airway maintenance. Rocuronium a recently introduced nondepolarizing neuromuscular blocker with a fast onset. The aim of this study was to evaluate onset time and duration of rocuronium effects in patients undergoing renal transplantation. Methods - Sixty patients were allocated into two groups of 30: Group R (GR) = patients undergoing renal transplantation and Group N (GN) = patients with normal renal function. All patients were premedicated with oral midazolam (15 mg) and anesthesia was induced with 30 μg.kg-1 alfentanil, 0.3 mg.kg-1 etomidate and 0.6 mg.kg-1 rocuronium injected through a central venous catheter. neuromuscular block was monitored by acceleromyography in the ulnar nerve pathway. The following parameters were evaluated: time between administration of rocuronium and first twitch reduction to 5% after supra-maximal stimulation (T1) (onset time = OT); time for first twitch to return to 25% (clinical duration = R25); time elapsed between 25% and 75% recovery of first twitch (relaxation recovery time = R25-75). Heart rate (HR) and mean blood pressure (MBP) were recorded in 6 moments. Results - Median OT was 31 sec. in GR and 47 sec. in GN. Median R25 was 51.5 min in GR and 33.5 min in GN. Median R25-75 was 28 min in GR and 20 min in GN. MBP and HR were higher in GR. Tracheal intubation conditions were excellent for most patients in both groups. Conclusions - These results open the possibility of 0.6 mg.kg-1 rocuronium being injected through a central venous catheter when a faster onset is needed. Due to wide differences in individual responses, monitoring of neuromuscular block is recommended.
Comparação entre o desempenho motor de hommes e mulheres em séries múltiplas de exercícios com pesos
Resumo:
The magnitude of men and women's neuromuscular, metabolic, and morphologic responses seems to be quite different even when both are submitted to exercise protocols using similar weight exercises protocols. However, differences in the motor performance between men and women have been predominantly reported in protocols based on isometric and isokinetic contractions. Thus, this study aimed to analyze men and women's behavior during multiple sets of weight exercises achieving the exhaustion, and later verifying possible differences as to the physical performance between genders using weights with similar intensity. For this, 83 subjects (50 men, and 33 women), 48 hours after being submitted to 1-RM tests in bench press, squat and arm curl performed a protocol composed by four sets at 1-RM 80% up to achieving the exhaustion in each of three exercises to evaluate the endurance ability to the fatigue in different muscular groups. It was used the ANOVA and ANCOVA for repeated measurements, followed by the Tukey's post hoc test, where P < 0.05 to the data treatment. It was verified a significant fall in the performance both in men and in women since the first up to the fourth sets of every exercise investigated (P < 0.01). Although the fatigue magnitude was higher in men in all the three exercises, the effect on the gender was only identified in the arm curl exercise (P < 0.01). The results of this study indicated that men and women presented quite different behavior in multiple sets of weight exercises, and women presented a more stable performance and a higher endurance ability to the fatigue in the arm curl as well.
Resumo:
Single frequency GPS receivers have been many used in GPS surveys. Among the several applications, one can mention those that are to obtain the receiver's antenna coordinates in real time. One of the main error sources to these applications is the ionosphere systematic error. In the FCT/UNESP a regional ionosphere model (Mod_Ion) was developed. It has been implemented to execute after collecting of GPS data. At real time application two improvements in the Mod_Ion were introduced, consisting of an alteration of the function of modeling and implementation of the Kalman Filter. The results of the experiments showed that the modifications were the most effective in the ionosphere systematic effect's corrections, providing a improvement in the accuracy of point positioning, of 90,75%, in period of the highest ionosphere activity.
Resumo:
Objective. To evaluate the influence of previous adaptation to different computational environments in visuo-spacial tasks performance of healthy individuals. Method. Healthy volunteers (n = 30), 15 male, mean age 25.3 ± 3.3 years, were divided in three groups: the first group, considered control, was not adapted to the proposed environments; the second group was adapted to a closed environment (stable and expected), and the third group was adapted to an open environment A (unexpected). The proposed task was to go through two open environments B and C (maze). The dependent variables Time and Error were considered for the analysis. Results. It was observed that during the adaptation phase, in the Time variable, the groups presented a progressive improvement in the performance to each task (p = 0.0036). The group adapted in the A open environment, showed a tendency to be faster in the execution of B and C open environments tasks, than the group adapted in the closed environment (p = 0.068). Conclusion. The study suggests that subjects adapted to visuo-spacial tasks execution involving unknown and no guided situations, present a tendency to a better time performance in these tasks when compared to subjects adapted in fixed and guided situations.
Resumo:
The purpose of this work is to compare two methods for time estimation of useful life for a small and shallow reservoir, located in Pirassununga, São Paulo State, Brazil: 1) sedimentometry; and 2) bathymetry. The model indicated a useful lifetime around 50 years for the studied dam. The values are between 51 years for the initial years of 1998/1999, and 46 years for the final years of 2004/2005, with an oscillation between 1999/2000 of 27 years, and between 2000/2001 of 76 years. The results show that it is possible to estimate the useful lifetime for small dams through the sedimentometric method, by knowing the correction coefficient value (K'). The coefficient is calculated using time values of useful lifetime calculated by the sedimentometric and bathymetric methods simultaneously, during the span of one year.
Resumo:
GPS active networks are more and more used in geodetic surveying and scientific experiments, as water vapor monitoring in the atmosphere and lithosphere plate movement. Among the methods of GPS positioning, Precise Point Positioning (PPP) has provided very good results. A characteristic of PPP is related to the modeling and / or estimation of the errors involved in this method. The accuracy obtained for the coordinates can reach few millimeters. Seasonal effects can affect such accuracy if they are not consistent treated during the data processing. Coordinates time series analyses have been realized using Fourier or Harmonics spectral analyses, wavelets, least squares estimation among others. An approach is presented in this paper aiming to investigate the seasonal effects included in the stations coordinates time series. Experiments were carried out using data from stations Manaus (NAUS) and Fortaleza (BRFT) which belong to the Brazilian Continuous GPS Network (RBMC). The coordinates of these stations were estimated daily using PPP and were analyzed through wavelets for identification of the periods of the seasonal effects (annual and semi-annual) in each time series. These effects were removed by means of a filtering process applied in the series via the least squares adjustment (LSQ) of a periodic function. The results showed that the combination of these two mathematical tools, wavelets and LSQ, is an interesting and efficient technique for removal of seasonal effects in time series.
Resumo:
New classes of martensitic stainless steels, with low carbon levels, have been developed aiming to meet the needs of the petroleum industry segment. However, their use has been restricted due to the fact it is a recent development and many of its properties are still under investigation. This work determines the values of initial and final temperatures for the austenitic transformation and the initial and final temperatures of martensitic formation for alloy 13Cr2Ni0,1C, by means of dilatometric tests under continuous cooling. Based on these results the optimized conditions for quench and temper heat treatments were obtained. The microstructural characterization of the alloys under coarse fusion condition was carried out by optical microscopy and the presence of delta-ferrite in the martensitic matrix was observed.
Resumo:
The aim of this study was to evaluate the effect of deboning time on broiler breeder hen meat for in natura consumption. Eighty samples of breast fillets with bone (Pectoralis major muscle) were collected and divided into four groups of 20 samples each; each group represented a different post-mortem deboning time: 0 (immediately after cooling), 4, 8 and 12h post-mortem. At 24h post-mortem, all samples were evaluated for the following parameters: pH, color (L*, a* and b*), cooking loss, water retention capacity, shear force, myofibrillar fragmentation index and fiber diameter. Color (L*, a* and b*), cooking loss, water retention capacity and shear force were significantly different (p ≥ 0.05) among the evaluated deboning times. The shear force value of breast fillets deboned at 0h post-mortem (8.478) was significantly different (p ≥ 0.05) from those deboned at 4, 8 and 12h post-mortem (5.154; 5.375 and 4.819, respectively). Therefore, an increase in the tenderness of breast fillets was observed, when deboning was performed at least 4h post-mortem.
Resumo:
This work aimed to evaluate the effect of increasing dietary fiber levels on the digestibility and gastrointestinal transit time (GTT) for pacu. The digestibility trial used 288 pacu in a completely randomized design, fed in aquaria and transferred to a modified Guelf-type feces collector, using the partial sampling method. The inert marker on the diets was chromic oxide (1%) to establish the diet digestibility. In the GTT assay, 288 pacu were distributed in 24 aquaria in a completely randomized design. Fish were fed with two colored diets - green and white - and feces color was determined after abdominal pressure. The white and green diets used 1% of titanium and chromic oxides, respectively. Total GTT was determined when all fish showed green feces. The apparent digestibility coefficients and GTT of diets decreased as dietary fiber levels increased. These results indicated that 9% dietary fiber can be used in pacu diets without negative effects on energy, protein, crude fiber and ether extract digestibility and GTT.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Landfill is an engineering work that aims at to accommodate residues in the smallest possible space in the soil, with minimum damages to the environment and the public health. One in the constructive forms of a controlled landfill is the excavation of ditches with appropriate dimensions, for disposition of solid residues without compactation or impermeabilization. Liquid effluents generated for similar volumes of residues, disposed in ditches with ages different from closing, it should result in physical and chemical alterations you correlated at the time of residence materials. With base in this hypothesis, measures of electric resistivity were accomplished through the of Eletrical Resistivity geophysical method, on residues ditches closed annually between 12/2001 and 12/2007, localized in control landfill of the Cordeirópolis city (SP). The leachate is a liquid effluent generated by the decomposition of organic matter and characterized by high content in total dissolved solids, whose interaction with geological environment results in alterations in terms of electrical resistivity susceptible to detection for the geophysical instrumental. The results suggest a resistivity reduction for leachate percolation produced for ditches recently and increase progressive of the resistivity for older ditches. The statistical comparative analysis with reference values for the area suggests ages of the finish production and percolation leachate for soil and rock below the ditches.
Resumo:
The transit time of seeds ingested by frugivorous animals has important implications for the spatial distribution of seeds and their dispersal distance. Nevertheless, this parameter is rarely included in seed dispersal studies. In this paper, we provide information about the transit time of seeds of nine species of plants ingested by individuals of six species of captive birds (Turdus albicollis, T. amaurochalinus, T. leucomelas, T. rufiventris, Stephanophorus diadematus and Saltator similis). We found that (1) seeds are regurgitated quickly through the digestive tract of birds than defecated seeds, and (2) large seeds (e.g., > 5 mm in diameter for Turdus spp.) are regurgitated rather than defecated. These results corroborate other studies, but the relationship between seed size and transit time seems to be quite complex and variable, requiring more detailed studies on this important aspect of the ecology of seed dispersal and digestive physiology of frugivorous birds.