283 resultados para Pendulum appliance


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dynamics of a bright matter wave soliton in a quasi one-dimensional Bose-Einstein condensate (BEC) with a periodically rapidly varying time trap is considered. The governing equation is based on averaging the fast modulations of the Gross-Pitaevskii (GP) equation. This equation has the form of a GP equation with an effective potential of a more complicated structure than an unperturbed trap. In the case of an inverted (expulsive) quadratic trap corresponding to an unstable GP equation, the effective potential can be stable. For the bounded space trap potential it is showed that bifurcation exists, i.e. the single-well potential bifurcates to the triple-well effective potential. The stabilization of a BEC cloud on-site state in the temporary modulated optical lattice is found. This phenomenon is analogous to the Kapitza stabilization of an inverted pendulum. The analytical predictions of the averaged GP equation are confirmed by numerical simulations of the full GP equation with rapid perturbations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present report describes the management of a radicular cyst in a 5-year-old child. The treatment comprised extraction of the primary teeth involved followed by marsupialization. A removable appliance with a resin extension penetrating into the cystic cavity was used to help decompress the lesion. This treatment allowed rapid healing of the lesion and eruption of the permanent incisors without the need for orthodontic treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims at a better comprehension of the features of the solution surface of a dynamical system presenting a numerical procedure based on transient trajectories. For a given set of initial conditions an analysis is made, similar to that of a return map, looking for the new configuration of this set in the first Poincaré sections. The mentioned set of I.C. will result in a curve that can be fitted by a polynomial, i.e. an analytical expression that will be called initial function in the undamped case and transient function in the damped situation. Thus, it is possible to identify using analytical methods the main stable regions of the phase portrait without a long computational time, making easier a global comprehension of the nonlinear dynamics and the corresponding stability analysis of its solutions. This strategy allows foreseeing the dynamic behavior of the system close to the region of fundamental resonance, providing a better visualization of the structure of its phase portrait. The application chosen to present this methodology is a mechanical pendulum driven through a crankshaft that moves horizontally its suspension point.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Patients with fixed orthodontic appliances often experience an absolute increase in the number of Streptococci mutans colony-forming units (cfu). The aim of this investigation was to study the development of biofilm and S. mutans cfu in connection with stainless steel ligatures and elastomeric rings in orthodontic patients treated with and without 0.4% stannous fluoride gel (SFG). Material: Forty-seven patients were divided into 2 groups: those treated with 0.4% SFG for 4 minutes (experimental) and those without 0.4% SFG (control). In each patient, elastomeric rings were used for ligation on 1 side of the dental arch midline, and stainless steel ligatures were used on the opposite side. Saliva samples were collected before and after appliance placement. At 15 and 30 days after appliance placement, biofilm samples from the stainless steel ligatures and the elastomeric rings were collected and subjected to microbiologic procedures and scanning electron microscopy (SEM) analysis. Results: The numbers of S. mutans cfu in the saliva and biofilm were not statistically different between the teeth fitted with elastomeric rings and stainless steel ligatures, or between the experimental and control groups. SEM analysis showed biofilm formation on both ligature ties. Conclusions: Topical application of 0.4% SFG in orthodontic patients with elastomeric rings or stainless steel ligatures does not cause a significant decrease in S. mutans cfu in the saliva and biofilm. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium dioxide (rutile) has a lot of interesting and useful features and hence is widely utilized for application. It has been used as white pigment, photocatalyst, biocompatible material and semiconductor material used in solar battery. In semiconducting TiO2 oxygen vacancies are said to play an important role in the electrical conduction. Measurements of the elastic energy loss and modulus (anelastic spectroscopy) as a function of temperature can distinguish among the different atomic jumps, which occur in the various phases or at different local ordering. In this paper, it is reported anelastic relaxation measurements in TiO2 samples using a torsion pendulum operating in frequencies around 40Hz, in the temperature range between -173°C to 330°C with heating rate of 1°C/min. The results shown a reduction in the elasticity modulus with the increase in the corn starch content used for this consolidation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Engineering ceramics have found use in many applications, such as engine parts, ball bearings, artificial bone and hip replacements and gyroscopes, because of their good chemical inertness, hardness, high temperature stability and excellent wear resistance. Oxide ceramic may meet these demands. Alumina (Al2O3) ceramics offer a high potential for many engineering applications, such as wear- and/or corrosion-resistant components, and as material for substrates or housings in microelectronic devices. Alumina is used among other things for seal ring, draw-cones, guides, water mixing tapes, bearing parts, medical prostheses and cutting tools. Measurements of the elastic energy loss and modulus (anelastic spectroscopy) as a function of temperature can distinguish among the different atomic jumps, which occurs in the various phases or at different local ordering. In this paper, it is reported anelastic relaxation measurements in Al2O3 samples using commercial starch. These measurements were carried out in a torsion pendulum operating in frequencies around 40 Hz. The results shown strongly influence of the type of forming in the elastic modulus obtained by anelastic relaxation measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the discovery of the high Tc superconductors, several works have been made about the different properties of these materials. Anelastic spectroscopy experiments are sensitive tools to the study of defects in solids and phase transitions. By this technique, we can distinguish the different types of atomic jumps that happen to different temperatures. The intensity of the peaks in the anelastic spectrum and the step in the torsional modulus are related with the concentration of the relaxing entities, and the position of the peaks is determined by its mobility. In this paper, the study on Bi and Sm based superconducting oxides was made by anelastic relaxation measurements using a torsion pendulum. The samples were submitted to successive thermal treatments in high vacuum, in the temperature range between 100 K and 650 K, heating rate about 1 K/min. For Bi based superconducting oxides the results shown two peaks, that were associated to interstitial oxygen mobility and to orthorhombic to monoclinic phase transition. For Sm based superconducting oxides the results shown a relaxation peak that was attributed to the jumps of the oxygen atoms in the inter-chains O1 and 05 of the lattice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. Purpose: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). Methods: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. Results: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. Conclusion: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies have been done to achieve biomedical alloys containing non-toxic elements and presenting low elastic moduli. It has been reported that Ti-Nb-Zr alloys rich in beta phase, especially Ti-13Nb-13Zr, have potential characteristics for substituting conventional materials such as Ti-6Al-4V, stainless steel and Co alloys. The aim of this work is to study the internal friction (IF) of Ti-13Nb-13Zr (TNZ) alloy due to the importance of the absorption impacts in orthopedic applications. The internal friction of this alloy produced by arc melting was measured using an inverted torsion pendulum with the free decay method. The measurements were performed from 77 to 700 K with heating rate of 1 K/min, in a vacuum better than 10-5 mBar. The results show a relaxation structure at high temperature strongly dependent on microstructure of the material. Qualitative discussions are presented for the experimental results, and the possibility of using the TNZ as a high damping material is briefly mentioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anelastic spectroscopy (internal friction and the dynamic modulus) was measured by means of a torsion pendulum at 3-12 Hz, in the range of 100-300 K, for a KAP metaphosphate glass. Two thermally activated internal friction peaks appeared at ∼190 and ∼250 K. These peaks were attributed to the behavior of potassium ions (high temperature) and to hydrogen (low temperature). Dynamic modulus showed a gradual decrease with increasing temperature in the range studied for all compositions. © 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metals and alloys containing solute atoms dissolved interstitially often show anelastic behavior due to a process know as stress-induced ordering. The application of mechanical spectroscopy measurements to diffusion studies in body-centered cubic metals has been extensively used in the last decades. However the kind of preferential occupation of interstitial solutes in body-centered cubic metals is still controversial. The anelastic properties of the Nb and Nb-1 wt% Zr polycrystalline alloys were determined by internal friction and oscillation frequency measurements using a torsion pendulum inverted performed between 300K and 650K, operating in a frequency oscillation in the hertz bandwidth. The interstitial diffusion coefficients of oxygen and nitrogen in Nb and Nb-1 wt% Zr samples were determined at two distinct conditions: (a) for low concentration of oxygen and (b) for high concentration of oxygen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vivo experimental study evaluated the efficacy of fluoride-releasing elastomers in the control of Streptococcus mutans levels in the oral cavity. Forty orthodontic patients were recruited and divided into two groups of 20. Fluoride-releasing elastomeric ligature ties (Fluor-I-Ties, Ortho Arch Co. Inc., USA) were used in the experimental group, and conventional elastomeric ligature ties (D. Morelli, Brazil), in the control group. Two initial samples of saliva were collected at a 14-day interval to determine the number of colony forming units (CFU) of Streptococcus mutans. Immediately after collecting the second sample, fluoride-releasing elastomeric ligature ties were placed in the patients of the experimental group, and conventional ligature ties, in the patients of the control group. Seven, 14 and 28 days after placement of the elastomeric ligature ties, saliva and plaque surrounding the orthodontic appliance were collected for microbiologic analysis. There were no significant differences in the number of Streptococcus mutans CFUs in saliva or plaque in the area surrounding the fluoride-releasing or conventional elastomeric ligature ties. Thus, fluoride-releasing elastomeric ligature ties should not be indicated to reduce the incidence of enamel decalcification in orthodontic patients. Since there was no significant reduction in S. mutans in saliva or plaque, other means of prevention against enamel decalcification should be indicated for these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to assess the salivary residual effect of fluoride dentifrice on human enamel subjected to an erosive challenge. This crossover in situ study was performed in two phases (A and B), involving ten volunteers. In each phase, they wore acrylic palatal appliances, each containing 3 human enamel blocks, during 7 days. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 minutes, 4 times a day. Dentifrice was used to brush the volunteers' teeth, 4 times a day, during 1 minute, before the appliance was replaced into the mouth. In phases A and B the dentifrices used had the same formulation, except for the absence (PD) or presence (FD) of fluoride, respectively. Enamel alterations were determined using profilometry, microhardness (%SMHC), acid- and alkali-soluble F analysis. The data were tested using ANOVA (p < 0.05). The concentrations (mean ± SD) of alkali- and acid-soluble F (μgF/cm 2) were, respectively, PD: 1.27 a ± 0.70/2.24∧ A ± 0.36 and FD: 1.49 a ± 0.44/2.24∧ ± 0.67 (p > 0.05). The mean wear values (± SD, μm) were PD: 3.63 a ± 1.54 and FD: 3.54 a ± 0.90 (p > 0.05). The mean %SMHC values (± SD) were PD: 89.63 a ± 4.73 and FD: 87.28 a ± 4.01 (p > 0.05). Thus, we concluded that the residual fluoride from the fluoride-containing dentifrice did not protect enamel against erosion.