254 resultados para Needle bearings


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article some considerations obtained during the utilization of rotor response analysis techniques in hydraulic powerplants are discussed. An applied research work was carried out in two hydraulic turbines analysing the rotor response both theoretically and experimentally. A developed mathematical model was used to simulate the rotordynamic behaviour of Francis and Kaplan turbines. The main dynamical effects that appear during the operation of the machines are discussed too. A series of measurements were carried out in the turbines using impact hammers to determine the modal behaviour of the units. The tests were carried out with the machine still and in operation. Some results and the comparison with the theory is presented in this article. The improved theoretical model was used for a sensitivity analysis of the different bearings to the main excitations that fake place during the machine operation. From this analysis, the best measuring points for condition monitoring were determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The malate dehydrogenase (MDH) and ascorbate oxidase were immobilized independently, onto silanized controlled porous silica and packed in a tygon tube. The reactors were inserted in the flow system, and the malic acid was determined by measurement of NADH produced by enzymatic reaction. The NADH was reoxidized in a wall jet cell that consisted of spectrographic graphite, Ag/AgCl, KCl(sat), and steel needle as work, reference, and counter electrodes, respectively. The current intensities were measured at 390 mV. The malate calibration curve shows a linear range from 5.0 x 10(-6) to 1.0 x 10(-4) molL(-1), the lifetime was 40 analyses, after that a decrease of 20% on the response is observed. Three different citric juices were analyzed and a good correlation between the proposed method and spectrophotometric commercial kit were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Litter production was measured for two years (november 1986 to october 1988) in a 29 year -old Pinus elliottii var. elliottii stand in differents resin treatments. Needle production comprised 9 to 93% of total litter fall, while the other categories (branches, barks, seeds and cones) were not significant. Maximum litterfall occurred in march to may 1987 (autumn) and the minimum was in august 1988 (winter) for all treatments and the control. No relationship appeared between annual litterfall and environmental factors, although there was a tendence to exhibit two periods of production: one in summer and other in winter. The results showed that in two years of resin extraction was not sufficient in interfering the litter fall and consequently the productivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aim of the study was to investigate the effect of acupuncture on wound healing after soft tissue or orthopaedic surgery in dogs.Methods: 29 dogs were submitted to soft tissue and/or orthopaedic surgeries. Five dogs had two surgical wounds each, so there were totally 34 wounds in the study. All owners received instructions for post operative care as well as antibiotic and pain treatment. The dogs were randomly assigned to treatment or control groups. Treated dogs received one dry needle acupuncture treatment right after surgery and the control group received no such treatment. A veterinary surgeon that was blinded to the treatment, evaluated the wounds at three and seven days after surgery in regard to oedema (scale 0-3), scabs (yes/no), exudate (yes/no), hematoma (yes/no), dermatitis (yes/no), and aspect of the wound (dry/humid).Results: There was no significant difference between the treatment and control groups in the variables evaluated three and seven days after surgery. However, oedema reduced significantly in the group treated with acupuncture at seven days compared to three days after surgery, possibly due the fact that there was more oedema in the treatment group at day three (although this difference was nor significant between groups).Conclusions: The use of a single acupuncture treatment right after surgery in dogs did not appear to have any beneficial effects in surgical wound healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 21 normal adult male subjects, the muscular activity of the levator scapulae and rhomboideus major muscles was studied electromyographically during the movements of the shoulder and arm. Two single coaxial needle electrodes were used for registering the action potentials. Concerning shoulder movement, it was shown that the levator scapulae was active in elevation and rhomboideus major was active in retraction. Both muscles were inactive during protrusion, in most events. Concerning free movements of the arm, both muscles were active in abduction, elevation, adduction, flexion and circumduction, but inactive in extension. During the same movements, performed with a load, we observed greater intensity in the activity of these muscles in comparison to their activity during free movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The participation of the levator scapulae and rhomboideus major muscles in some movements of the upper limb was analysed in 21 young adult male volunteers. A 2 channel TECA TE4 electromyograph connected with single coaxial needle electrodes was used. In abduction, elevation, adduction, flexion and circumduction participation of both muscles in free movements of the upper limb was found. In extension, however, these muscles were inactive. In the same movements analysed with load, a major intensity of action of these muscles was registered as compared with those obtained in free movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The participation of the trapezius (middle portion) and rhomboideus major muscles submitted to an isometric tension (holding downward dumbells of 11, 15 and 19 kg) was analysed in 40 young adult male vounteers. A 2 channel TECA TE4 electromyograph connected with single coaxial needle electrodes was used. In the initial phase of the test, holding downward, generally the trapezius and rhomboideus major muscles showed activity and no activity, respectively. In the cases where activity was present during the downward positions it was reduced gradually until complete rest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The trapezius (pars superior) and levator scapulae mm were studied in the arm movements of circumduction and pendular oscillation in 30 adult volunteers of both sexes. A two-channel TECA TE 4 electromyograph and single coaxial needle electrodes were used. It was found out that as arm conduction, both muscles show an activity that gradually increases and decreases the intensity at the elevation and lowering phases respectively. It was also noticed that between two consecutive circumductions a 'silent period' in the activity of the above mentioned muscles occurs. In pendular oscillation these muscles show electrical activity both in the forward and backward moving, and both muscles show a 'silent period' when the arm passes by the trunk. It was not observed in these movements any significant difference in activity of these muscles regarding sex.