251 resultados para Muscular Load
Resumo:
We performed hyperglycemic clamps in 283 nondiabetic Caucasians and, with multiple linear regression, determined the contribution of beta-cell function and tissue insulin sensitivity to variations in glycemia and insulinemia during oral glucose tolerance tests (OGTTs). Impaired glucose tolerance (IGT) subjects had reduced insulin sensitivity(P < .02) and beta-cell function (P < .0001). Normal glucose tolerance (NGT) subjects with first-degree type 2 diabetic relatives had reduced first and second phase insulin secretion (both, P < .05), but normal insulin sensitivity(P = .37). beta-Cell function and insulin sensitivity accounted for one fourth of the variability in glucose tolerance. Fasting plasma glucose in subjects with NGT (n = 185) was a function of both phases of insulin secretion and of insulin sensitivity tall, P < .05), whereas, in IGT subjects (n = 98), it was a function of first phase insulin secretion and insulin sensitivity(P < .01). Two-hour glycemia was a function of second phase secretion and insulin sensitivity (P < .01). Fasting and 2-hour plasma insulin levels were determined by insulin sensitivity land glycemia) in NGT subjects (P < .001), but by second phase secretion in IGT (P < .001). We conclude that beta-cell function is reduced in subjects with IGT; glycemia and insulinemia are not regulated by the same mechanisms in IGT and NGT; insulin sensitivity does not contribute to insulinemia in IGT; family history of diabetes influences beta-cell function, but not insulin sensitivity in Caucasians. Copyright (C) 2000 by W.B. Saunders Company.
Resumo:
This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and other in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the determination of the compensation susceptances is based on the instantaneous values of load currents. The results are obtained using the MatLab-Simulink enviroment
Resumo:
The induction motors are largely used in several industry sectors. The dimensioning of an induction motor has still been inaccurate because in most of the cases the load behavior in its shaft is completely unknown. The proposal of this paper is to use artificial neural networks as tool for dimensioning of induction motors rather than conventional methods, which use classical identification techniques and mechanical load modeling. Simulation results are also presented to validate the proposed approach.
Resumo:
Observe the loads associates application with in position of body, in the static or dynamic postures. Methods: the electromyographic study in erector spinae, rectus abdominis, glutaeous maximus and rectus femoris muscles was accomplished in female volunteers from 18 have 27 years old, previously selected. The muscles electric activities was gotten with surface electrodes, in standing and static posture, with the parallels and horizontal upper limbs with load on their hands. Conclusion: In this study it was clearly observed influence of the load and distance there is over studied musculature associated with standing erect posture.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper was evaluated, using the software ANSYS, the stiffness (El) of the log-concrete composite beams, of section T, with connectors formed by bonded-in steel rods, type CA-50, disposed in X, with application of cyclical load. The stiffness of the system was evaluated through the simulation of bending tests, considered 1/2 beam, with cyclical shipment varying among 40 % and 5 % of the strength of the connection with the load relationship R=0,125, for a total of 10 load cycles applied. The numeric results show a good agreement with experimental tests.
Resumo:
A multi-agent framework for spatial electric load forecasting, especially suited to simulate the different dynamics involved on distribution systems, is presented. The service zone is divided into several sub-zones, each subzone is considered as an independent agent identified with a corresponding load level, and their relationships with the neighbor zones are represented as development probabilities. With this setting, different kind of agents can be developed to simulate the growth pattern of the loads in distribution systems. This paper presents two different kinds of agents to simulate different situations, presenting some promissory results.
Resumo:
In 21 normal adult male subjects, the muscular activity of the levator scapulae and rhomboideus major muscles was studied electromyographically during the movements of the shoulder and arm. Two single coaxial needle electrodes were used for registering the action potentials. Concerning shoulder movement, it was shown that the levator scapulae was active in elevation and rhomboideus major was active in retraction. Both muscles were inactive during protrusion, in most events. Concerning free movements of the arm, both muscles were active in abduction, elevation, adduction, flexion and circumduction, but inactive in extension. During the same movements, performed with a load, we observed greater intensity in the activity of these muscles in comparison to their activity during free movements.
Resumo:
The use of anthropometric measurements of triceps (TSF) and subscapular skinfolds (SSF) and mid-upper arm muscle circumference (MAMC) was examined as far as the diagnosis of energy-protein malnutrition (EPM) is concerned. The study was undertaken in five groups of patients (n = 231): arterial hypertension (AH, n = 63), chronic obstructive pulmonary disease (COPD, n = 17), hemodialyzed chronic renal failure (CRF, n = 19), critically ill patients with an acute event (CA, n = 42) and critically ill patients with chronic diseases (CCD, n = 90). The results were compared to those obtained in a group of healthy individuals (control group, n = 102). The control group and the group of patients were allocated in subgroups according to sex and age (less than 50 and more than 50 years). It was expected that significant differences would be found for the anthropometric values between the control subgroups and the COPD, the CRF and the CCD subgroups of patients. For the skinfold thicknesses (TSF and SSF), significant differences were found between CRF, CCD subgroups and the control subgroups under fifty years of age; however, the differences were not significant when the subgroups over fifty were analyzed. Concerning the MAMC, significant differences were found: 1 degree) between the CRF subgroups (males and females) and the control subgroups under fifty years of age; 2 degrees) between the CCD male subgroups (younger and older subgroups) and the respective control subgroups and 3 degrees) between the COPD and the control subgroups.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
This work shows a computational methodology for the determination of synchronous machines parameters using load rejection test data. The quadrature axis parameters are obtained with a rejection under an arbitrary reference, reducing the present difficulties.
Resumo:
The objective of this work is the development of a methodology for electric load forecasting based on a neural network. Here, it is used Backpropagation algorithm with an adaptive process based on fuzzy logic. This methodology results in fast training, when compared to the conventional formulation of Backpropagation algorithm. Results are presented using data from a Brazilian Electric Company and the performance is very good for the proposal objective.
Resumo:
This work shows a computational methodology for the determination of synchronous machines parameters using load rejection test data. By machine modeling one can obtain the quadrature parameters through a load rejection under an arbitrary reference, reducing the present difficulties. The proposed method is applied to a real machine.
Resumo:
Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.