175 resultados para Maximum Power Point Tracking System (MPPT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Horticultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Facial asymmetry is a common human characteristic and can occur on many levels, originate of genetic factors, and can be caused by traumas or due to cross bite and/or muscular disability. The aim of this study was to evaluate the relation between posterior crossbite, median line deviation and facial asymmetry. For this study 70 children aged between 3 and 10 years-old were examined and photographed. Using Microsoft Office Power Point 2007, horizontal lines and one vertical line on median line were drawn, to subjectively analyze facial discrepancies. In relation to overjet, the majority of children (78.6%) showed normal relation, followed by high overjet (17.1%), anterior crossbite (4.3%). In relation to overbite, the majority of children (60%) showed normal relation, 27.1% anterior opened bite (negative overbite), and 12.9% showed high overbite. Posterior crossbite was present in 27.1% of children. Among them, 68.4% showed unilateral crossbite on right side, 21.1% bilateral crossbite and 10.5% unilateral crossbite on left side. The relation between posterior crossbite and facial asymmetry, according to Fisher´s Exact Test (p=0.0970), there was no statistically significant association. In relation to median line, the association was statistically significant with posterior crossbite (p=0.0109) and with facial asymmetry (p=0.0310). There was association between posterior crossbite and median line deviation. There was no association between posterior crossbite and facial asymmetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to examine changes on anaerobic power after competitive period in professional soccer players. Twenty five male was evaluated before (PRE) and after (POS) competitive period. To assess anaerobic power was used running based on anaerobic sprint test (RAST), which were determined the maximum power (MAXP), medium power (MEDP), minimum power (MINP) and fatigue index (FI). The test was performed in the first (PRE) and the last (POS) training session of competitive period, wich lasted 20 weeks. There were no significant difference (p>0,05) in POS condition compared to PRE condition on MAXP (10,70 ± 0,95 vs 10,83 ± 0,87), MINP (8,48 ± 0,92 vs 8,28 ± 0,76), MEDP (9,52 ± 0,83 vs 9,41 ± 0,61) and FI (22,73 ± 7,48 vs 25,53 ± 8,79). There was no significant change on anaerobic power after a competitive period wich lasted 20 weeks in professional soccer players.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is little information on Caribbean soccer players. Thus, the aim this study was to descriptive and to compare the anthropometric, motor and aerobic fitness profile between Trinidad and Tobago team professional and junior soccer players. Twenty six soccer players were evaluated (14 professional and 12 junior): anthropometric (height, body mass, BMI, body fat percent), flexibility (sit and reach), velocity (30 m), explosive strength (horizontal and vertical jump), anaerobic power (maximum, mean and minimum power, index of fatigue) and maximum aerobic power. Student Test-t to independent sample was used in statistical analyzes, considering 5% of significance (p<0,05). Results of professional and junior players were, respectively: height (180,6 ± 8,1; 175,0 ± 6,9 cm), body mass (77,1 ± 7,5; 70,6 ± 8,7 kg); BMI (23,6 ± 1,5 / 23,0 ± 1,6 kgm 2 ); body fat (11,9 ± 1,7; 11,6 ± 1,2 %); sitting and reaching (24,9 ± 10,3; 24,9 ± 7,7 cm); velocity (30 m) (4,61 ± 0,14; 4,66 ± 0,15 s); horizontal jump (263,4 ± 14,9; 239,7 ± 12,1 cm); vertical jump (58,7 ± 4,3; 54,6 ± 6,6 cm); maximum power (7,9 ± 0,9; 6,6 ± 0,8 w∙kg-1 ); mean power (6,5 ± 0,7; 5,4 ± 0,9 w∙kg-1 ); minimum power (5,3 ± 0,7; 4,3 ± 1,1 w∙kg-1 ); index of fatigue (33,0 ± 7,9; 34,8 ± 12,8 %); aerobic power (55,0 ± 3,2; 57,2 ± 4,8 ml∙kg-1 ∙min-1 ). Professional players presented higher horizontal jump and maximum, mean and minimum anaerobic power in comparing to the junior players. The highest values of power tests for the lower limbs may be relationship to the longer time of practice in the modality of professional players, which can also indicate a higher level of specialization, which gives priority to the training of power (force and velocity).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The distribution of natural gas is carried out by means of long ducts and intermediate compression stations to compensate the pressure drops due to friction. The natural gas compressors are usually driven by an electric motor or a gas turbine system, offering possibilities for energy management, one of these consisting in generating energy for use in-plant or to commercialize as independent power producer. It can be done by matching the natural gas demand, at the minimum pressure allowed in the reception point, and the storage capacity of the feed duct with the maximum compressor capacity, for storing the natural gas at the maximum permitted pressure. This allows the gas turbine to drive an electric generator during the time in which the decreasing pressure in duct is above the minimum acceptable by the sink unit. In this paper, a line-pack management analysis is done for an existing compression station considering its actual demand curve for determining the economic feasibility of maintaining the gas turbine system driver generating electricity in a peak and off-peak tariff structure. The potential of cost reduction from the point of view of energy resources (natural gas and electric costs) is also analyzed. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this work a switching feedback controller for stick-slip compensation of a 2-DOF mass-spring-belt system which interacts with an energy source of limited power supply (non-ideal case) is developed. The system presents an oscillatory behavior due to the stick-slip friction. As the system equilibrium for a conventional feedback controller is not the origin, a switching control law combining a state feedback term and a discontinuous term is proposed to regulate the position of the mass. The problem of tracking a desired periodic trajectory is also considered. The feedback system is robust with respect to the friction force that is assumed to be within known upper and lower bounds.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

An optimisation technique to solve transmission network expansion planning problem, using the AC model, is presented. This is a very complex mixed integer nonlinear programming problem. A constructive heuristic algorithm aimed at obtaining an excellent quality solution for this problem is presented. An interior point method is employed to solve nonlinear programming problems during the solution steps of the algorithm. Results of the tests, carried out with three electrical energy systems, show the capabilities of the method and also the viability of using the AC model to solve the problem.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this paper, to solve the reconfiguration problem of radial distribution systems a scatter search, which is a metaheuristic-based algorithm, is proposed. In the codification process of this algorithm a structure called node-depth representation is used. It then, via the operators and from the electrical power system point of view, results finding only radial topologies. In order to show the effectiveness, usefulness, and the efficiency of the proposed method, a commonly used test system, 135-bus, and a practical system, a part of Sao Paulo state's distribution network, 7052 bus, are conducted. Results confirm the efficiency of the proposed algorithm that can find high quality solutions satisfying all the physical and operational constraints of the problem.