182 resultados para Linear matrix inequalities (LMI) techniques
Resumo:
Naturally occuring or man-made systems displaying periodic spatial modulations of their properties on a nanoscale constitute superlattices. Such modulated structures are important both as prototypes of simple nanotechnological devices and as particular examples of emerging spatial inhomogeneity in interacting many-electron systems. Here we investigate the effect different types of modulation of the system parameters have on the ground-state energy and the charge-density distribution of the system. The superlattices are described by the inhomogeneous attractive Hubbard model, and the calculations are performed by density-functional and density-matrix renormalization group techniques. We find that modulations in local electric potentials are much more effective in shaping the system's properties than modulations in the attractive on-site interaction. This is the same conclusion we previously [M.F. Silva, N.A. Lima, A.L. Malvezzi, K. Capelle, Phys. Rev. B 71 (2005) 125130.] obtained for repulsive interactions, suggesting that it is not an artifact of a specific state, but a general property of modulated structures. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
An affine sl(n + 1) algebraic construction of the basic constrained KP hierarchy is presented. This hierarchy is analyzed using two approaches, namely linear matrix eigenvalue problem on hermitian symmetric space and constrained KP Lax formulation and it is shown that these approaches are equivalent. The model is recognized to be the generalized non-linear Schrödinger (GNLS) hierarchy and it is used as a building block for a new class of constrained KP hierarchies. These constrained KP hierarchies are connected via similarity-Bäcklund transformations and interpolate between GNLS and multi-boson KP-Toda hierarchies. Our construction uncovers the origin of the Toda lattice structure behind the latter hierarchy. © 1995 American Institute of Physics.
Resumo:
We report the synthesis and the structural and magnetic characterization of two new compounds: dibromobis-(pdmp)copper(II), CuBr2C22H24N4 (1), and dichlorobis(pdmp)copper(II), CuCl2C22H24N4 (2), where pdmp = 1-phenyl-3,5-dimethylpyrazole. The structures were refined by full-matrix least-squares techniques to R1 = 0.0620 and 0.0777, respectively. Compound 1 belongs to the space group P21/n with a = 8.165(5) Å, b = 10.432(3) Å, c = 13.385(4) Å, β = 100.12(4)̊, and Z = 2. Compound 2 belongs to the space group P21/c with a = 8.379(2) Å, b = 22.630(2) Å, c = 12.256(2) Å, β= 98.43(3)°, and Z = 4. It has the same molecular formula as a compound reported previously but a different crystal structure. Detailed single-crystal EPR measurements were performed for single-crystal samples of 1 and 2 at 9 and 35 GHz and at room temperature. The positions and line widths of the EPR lines were measured as a function of the magnetic field orientation in three orthogonal planes. The data were used to study the electronic properties of the copper ions and to evaluate the exchange interactions between them. Our results are discussed in terms of the electronic pathways for superexchange between copper ions, which are provided by the stacking of pyrazole and phenyl rings of neighboring molecules and by hydrogen-halogen bonds. © 1999 American Chemical Society.
Resumo:
In the present work the thermal characteristics of gels and xerogels of Silica/organic hybrids derived from different concentrations of GPTS-TEOS were investigated by thermal analysis (TG, DTA, and DSC). The preparation of gels of the Silica/organic hybrid matrix was held through the sol-gel process, consisting by the hydrolysis of alkoxides GPTS and TEOS in proportion (1:1) and (1:2) that was promoted in acidic conditions under reflux and stirring at 80oC/2h, producing the matrix in the colloidal state (sol). Gels were prepared by addition of NH4OH to the sol, promoting gelation of sol in sealed plastics containers. Part of the gels samples was analyzed by TG, DTS and DSC techniques in order to characterize water loss and degradation of the polymeric “epoxy” groups present in the structure of the silica derived from the GPTS alkoxide. Another set of samples was dried at 80oC/48h to obtain xerogels (dried gels) and analyzed by the same techniques. We obtained the characteristics temperatures of the matrix by the techniques DTA, DSC and TG, under measurements of thermal analysis until 800oC and 600oC in case of DSC. By thermal analysis (TG, DTA, and DSC) the main endothermic events (loss of water, melting, pyrolysis) and exothermic events (burning of the polymer) of the GPTS-TEOS matrix were determined
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Let m and n be integers greater than 1. Given lattices A and B of dimensions m and n, respectively, a technique for constructing a lattice from them of dimension m+n-1 is introduced. Furthermore, if A and B possess bases satisfying certain conditions, then a second technique yields a lattice of dimension m+n-2. The relevant parameters of the new lattices are given in terms of the respective parameters of A,B, and a lattice C isometric to a sublattice of A and B. Denser sphere packings than previously known ones in dimensions 52, 68, 84, 248, 520, and 4098 are obtained. © 2012 Elsevier Inc. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Maize gluten feed (MGF) is a co-product of wet milling of maize, and is composed of structures that remain after most starch, gluten and germ has been extracted from the grain. Although currently used in dog foods, its digestibility and energy values have not been documented. Two techniques were used to determine nutrient digestibility of MGF for dog foods. Both techniques used extruded diets fed to Beagle dogs, with six replicates per diet. The first study used a difference method in which 300 g/kg of a reference diet was replaced by MGF. Based on the difference method, the coefficient of total tract apparent digestibility (CTTAD) of MGF was 0.53 for dry matter (DM), 0.69 for crude protein (CP), 0.74 for fat, 0.99 for starch, and 0.55 for gross energy (GE). The calculated metabolizable energy (ME) of MGF was 7.99 MJ/kg (as-fed). The second study used a regression method and included a basal diet and a basal diet with 70, 140 and 210 g MGF/kg of diet (as a substitute for maize starch). Maize gluten feed inclusion resulted in a linear reduction of CTTAD of DM (R(2)=0.99; P<0.001), CP (R(2)=0.95; P=0.002), fat (R(2)=0.87; P=0.009). starch (R(2)=0.81; P<0.001), and GE (R(2)=0.99; P<0.001). Faecal production increased linearly from 56 g to 107 g/dog/d (R(2)=0.99; P<0.001), with a linear reduction of faecal DM (R(2)=0.99: P<0.001) and a linear increase in faecal lactic acid concentration (P<0.02). Both urine (R(2)=0.77; P=0.029) and faeces (R(2)=0.92: P=0.019) showed a linear reduction in pH. Results of ingredient MAD obtained by the regression and difference methods were close (6% or less of variation) for CP, fat, and starch, and also for ME content (1.4% higher for the difference method), but the two methods disagreed on calculated CTTAD of DM and organic matter. The high dietary fiber content of MGF (382 g/kg) may explain the low digestibility of this ingredient. Maize gluten feed could be a useful ingredient for formulations designed to have low energy or reduce the urine pH of dogs. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a pole placement method using both the augmented Jacobian and the corresponding system transfer function matrices. From the manipulation of these matrices a straightforward approach results to get the coefficients of a non-linear system, whose solution gives the parameters of the stabilizers that can provide a pre-specified minimum damping to the system. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Structural Health Monitoring (SHM) has diverse potential applications, and many groups work in the development of tools and techniques for monitoring structural performance. These systems use arrays of sensors and can be integrated with remote or local computers. There are several different approaches that can be used to obtain information about the existence, location and extension of faults by non destructive tests. In this paper an experimental technique is proposed for damage location based on an observability grammian matrix. The dynamic properties of the structure are identified through experimental data using the eigensystem realization algorithm (ERA). Experimental tests were carried out in a structure through varying the mass of some elements. Output signals were obtained using accelerometers.
Resumo:
Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.
Resumo:
Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.