129 resultados para Line and edge detection
Resumo:
A new biflavonol, named chimarrhoside (1), and eight known flavonol glycosides (2-9), were isolated from the leaves of Chimarrhis turbinata. Their structures were established on the basis of 1D and 2D NMR experiments as quercetin-3-O-rutinoside (2), kaempferol-3-O-rutinoside (3), kaempferol-3-O-α-L-rhamnopyranosyl-(1→6)-β-D-galactopyranoside (4), quercetin-3-O-α-L-rhamnopyranosyl-(1→6)-β-D- galactopyranoside (5), 6-hydroxy-rutin (6), kaempferol-3-O-D-galactopyranoside (7), kaempferol-3-O-D-glucopyranoside (8) and kaempferol-3-O-α- Lrhamnopyranosyl-(1→6)-α-L-rhamnopyranosyl-(1→4) -β-D-glucopyranoside (9). In addition, catechin (10) and catechin-(4α→8)-catechin-procyanidin B-3) (11) were isolated. The crude extract, fractions and isolated compounds were evaluated for their antioxidative properties using an autographic assay based on β-carotene bleaching on TLC plates, and spectrophotometric detection by reduction of the stable 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical. Flavonoids 2, 5, 6, 10 and 11 displayed strong free radical scavenging activity, when compared with the standards BHT and rutin. ©2005 Sociedade Brasileira de Química.
Resumo:
A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow-cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III). The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2-210 μmol l-1 H2O2 with a LD of 1.8 μmol l-1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10-5 mol l-1 and 6.8×10-5 mol l-1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 μg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved. Copyright © Taylor & Francis Group, LLC.
Resumo:
DNA biosensors have gained increased attention over traditional diagnostic methods due to their fast and responsive operation and cost-effective design. The specificity of DNA biosensors relies on single-stranded oligonucleotide probes immobilized to a transduction platform. Here, we report the development of biosensors to detect the hippuricase gene (hipO) from Campylobacter jejuni using direct covalent coupling of thiol- and biotin-labeled single-stranded DNA (ssDNA) on both surface plasmon resonance (SPR) and diffraction optics technology (DOT, dotLab) transduction platforms. This is the first known report of the dotLab to detect targeted DNA. Application of 6-mercapto-1-hexanol as a spacer thiol for SPR gold surface created a self-assembled monolayer that removed unbound ssDNA and minimized non-specific detection. The detection limit of SPR sensors was shown to be 2.5 nM DNA while dotLab sensors demonstrated a slightly decreased detection limit of 5.0 nM (0.005 μM). It was possible to reuse the SPR sensor due to the negligible changes in sensor sensitivity (∼9.7 × 10 -7 ΔRU) and minimal damage to immobilized probes following use, whereas dotLab sensors could not be reused. Results indicated feasibility of optical biosensors for rapid and sensitive detection of the hipO gene of Campylobacter jejuni using specific ssDNA as a probe. © 2011 Elsevier B.V.
Resumo:
Non-pressure compensating drip hose is widely used for irrigation of vegetables and orchards. One limitation is that the lateral line length must be short to maintain uniformity due to head loss and slope. Any procedure to increase the length is appropriate because it represents low initial cost of the irrigation system. The hypothesis of this research is that it is possible to increase the lateral line length combining two points: using a larger spacing between emitters at the beginning of the lateral line and a smaller one after a certain distance; and allowing a higher pressure variation along the lateral line under an acceptable value of distribution uniformity. To evaluate this hypothesis, a nonlinear programming model (NLP) was developed. The input data are: diameter, roughness coefficient, pressure variation, emitter operational pressure, relationship between emitter discharge and pressure. The output data are: line length, discharge and length of the each section with different spacing between drippers, total discharge in the lateral line, multiple outlet adjustment coefficient, head losses, localized head loss, pressure variation, number of emitters, spacing between emitters, discharge in each emitter, and discharge per linear meter. The mathematical model developed was compared with the lateral line length obtained with the algebraic solution generated by the Darcy-Weisbach equation. The NLP model showed the best results since it generated the greater gain in the lateral line length, maintaining the uniformity and the flow variation under acceptable standards. It had also the lower flow variation, so its adoption is feasible and recommended.
Resumo:
The phases of a transmission line are tightly coupled due to mutual impedances and admittances of the line. One way to accomplish the calculations of currents and voltages in multi-phase lines consists in representing them in modal domain, where its n coupled phases are represented by their n propagation modes. The separation line in their modes of propagation is through the use of a modal transformation matrix whose columns are eigenvectors associated with the parameters of the line. Usually, this matrix is achieved through numerical methods which do not allow the achievement of an analytical model for line developed directly in the phases domain. This work will show an analytical model for phase currents and voltages of the line and results it will be applied to a hypothetical two-phase. It will be shown results obtained with that will be compared to results obtained using a classical model. © 2012 IEEE.
Resumo:
The preparation and electrochemical characterization of hausmannite-type manganese oxide to use as a sensing material for sodium ion is described. This paper reports a new via synthetic to obtain of the hausmannite-type manganese oxide and its application in the construction of modified electrode as a voltammetric sensor. The electrochemical activity of hausmannite-type manganese oxide is controlled by intercalation/deintercalation of the sodium ions within the oxide lattice. The detection is based on the measurement of anodic current generated by oxidation of MnIII-MnIV at electrode surface. The best electrochemical response was obtained for a sensor composition of 20% (w/w) hausmannite oxide in the paste, a TRIS buffer solution of pH 6.0-7.0 and a scan rate of 50 mV s-1. A sensitive linear voltammetric response for sodium ions was obtained in the concentration range of 2.01 × 10 -5-2.09 × 10-4 mol L-1 with a slope of 355 μA L mmol-1 and a detection limit of 7.50 × 10 -6 mol L-1 using cyclic voltammetry. The use of hausmannite has significantly improved the selectivity of the sensor compared to the birnessite-type manganese oxide modified electrode. Under the working conditions, the proposed method was successfully applied to determination of sodium ions in urine samples. © 2013 Elsevier B.V.
Resumo:
To investigate morphological and genomic differences between cutting and racing lines of Quarter Horses, 120 racing and 68 cutting animals of both sexes, registered at the Brazilian Association of Quarter Horse Breeders, were used. Blood samples were collected, and the following physical traits were measured: weight; height at withers; body length; length of the shank, pastern, rump, head, and neck; and chest, shank, and hoof circumference. For analysis of genomic differences, 54,602 single-nucleotide polymorphisms (SNPs) were genotyped using the Equine SNP50 BeadChip, and the quality of individual and SNP genotype data were evaluated. The fixation index, FST, was used to identify genome regions that were altered in the lines by selection. The results showed significant differences between the lines in all physical traits. Quality control led to the exclusion of four cutting animals with a call rate of <0.95. After filtering, 12,544, 13,815, and 13,370 SNPs were excluded for the whole population (n = 184), the 120 racing animals, and the 64 cutting animals, respectively. The number of informative polymorphisms detected in each line and in the whole population indicated that the Equine SNP50 BeadChip can be used in genetic studies of Quarter Horses. The fixation index, FST, identified 2,558 genome regions that may have been modified by divergent selection. © 2013 Elsevier Inc.
Resumo:
In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL (xsuperconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level. © 2002-2011 IEEE.
Resumo:
The phases of a transmission line are tightly coupled due to mutual impedances and admittances of the line. One way to accomplish the calculations of currents and voltages in multi phase lines consists in representing them in modal domain, where its n coupled phases are represented by their n propagation modes. The separation line in their modes of propagation is through the use of a modal transformation matrix whose columns are eigenvectors associated with the parameters of the line. Usually, this matrix is achieved through numerical methods which do not allow the achievement of an analytical model for line developed directly in the phases domain. This work will show an analytical model for phase currents and voltages of the line and results it will be applied to a hypothetical two-phase. It will be shown results obtained with that will be compared to results obtained using a classical model © 2003-2012 IEEE.
Resumo:
The objective was to evaluate serum activity of the enzymes creatine kinase (CK) and aspartate aminotransferase (AST), which are leakage enzymes responsive to muscle injury, of athletic horses that underwent muscle biopsy and incremental jump test (IJT) involving incremental jumps. The animals were grouped as follows: the first group, horses with history of superior performance (SP); the second, with a history of inferior performance (IP); and lastly, a control group (CG). All groups underwent biopsy of the gluteus medius muscle, while groups SP and IP were also submitted to the incremental jump test (IJT) 24 hours after biopsy. The IJT consisted of three stages with 40 jumps each, where jump height increased progressively, from 40 to 60 and last, 80cm. Blood samples were drawn before biopsy, and 6 and 24 hours after the exercise as well. The levels of CK serum activity increased 6 hours after exercise and decreased 24 hours later in all groups, including CG. AST activity did not increase after biopsy and exercise. There was no increase of both enzyme activities that could be attributed to the exercise, possibly due to exercise short duration and/or low intensity. We conclude that the muscle biopsy was able to show that there was enough stimulus to cause CK enzyme leakage into the plasma, and consequent detection of increased serum activity, while the incremental jump test did not.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Educação - FCT
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
Pós-graduação em Química - IQ