122 resultados para HEO line
Resumo:
This article summarizes the implementation of an online process management, analysis, and optimization tool at Lwarcel Celulose e Papel, within the PIMS and MES philosophy, for process indicator implementation, understanding of variables, and their cause-effect relationship in the process, as well as the achievement of operational benchmarking. The process analysis, by means of statistical tools, allied to mathematical modeling algorithms used in Wedge, makes it possible to identify the relevant information for process and quality improvement with regard to efficiency, equipment maintenance, productivity, and uniformity of the end product quality, reduction of unwanted shutdowns, and quicker resolution of process problems.
Resumo:
This article brings some of the results of a study that analyzes a hybrid course for in-service teachers in the Project Teletandem Brazil: foreign languages for all. In this project, Brazilian teachers of Spanish as a foreign language took part in a blended tandem learning course, communicating via videoconferencing with Uruguayan teachers of Portuguese as a foreign language. The aim of the study was to verify Brazilian teachers' concepts and beliefs concerning language and culture and how the teletandem interactions affected them. After the interactions, teachers' views of culture seemed to also incorporate aspects of culture as an interpersonal process, instead of the factual and static view which was previously predominant. Therefore teacher education programs must consider the possibility of conjugating theory and reflective practice through the use of videoconference tools in order to allow teachers to experience culture rather learn facts about it. © 2011 ACADEMY PUBLISHER.
Resumo:
The objective of this paper is to show a methodology to estimate the longitudinal parameters of transmission lines. The method is based on the modal analysis theory and developed from the currents and voltages measured at the sending and receiving ends of the line. Another proposal is to estimate the line impedance in function of the real-time load apparent power and power factor. The procedure is applied for a non-transposed 440 kV three-phase line. © 2011 IEEE.
Resumo:
We study polynomials which satisfy the same recurrence relation as the Szego{double acute} polynomials, however, with the restriction that the (reflection) coefficients in the recurrence are larger than one in modulus. Para-orthogonal polynomials that follow from these Szego{double acute} polynomials are also considered. With positive values for the reflection coefficients, zeros of the Szego{double acute} polynomials, para-orthogonal polynomials and associated quadrature rules are also studied. Finally, again with positive values for the reflection coefficients, interlacing properties of the Szego{double acute} polynomials and polynomials arising from canonical spectral transformations are obtained. © 2012 American Mathematical Society.
Resumo:
A Bayesian nonparametric model for Taguchi's on-line quality monitoring procedure for attributes is introduced. The proposed model may accommodate the original single shift setting to the more realistic situation of gradual quality deterioration and allows the incorporation of an expert's opinion on the production process. Based on the number of inspections to be carried out until a defective item is found, the Bayesian operation for the distribution function that represents the increasing sequence of defective fractions during a cycle considering a mixture of Dirichlet processes as prior distribution is performed. Bayes estimates for relevant quantities are also obtained. © 2012 Elsevier B.V.
Resumo:
Non-pressure compensating drip hose is widely used for irrigation of vegetables and orchards. One limitation is that the lateral line length must be short to maintain uniformity due to head loss and slope. Any procedure to increase the length is appropriate because it represents low initial cost of the irrigation system. The hypothesis of this research is that it is possible to increase the lateral line length combining two points: using a larger spacing between emitters at the beginning of the lateral line and a smaller one after a certain distance; and allowing a higher pressure variation along the lateral line under an acceptable value of distribution uniformity. To evaluate this hypothesis, a nonlinear programming model (NLP) was developed. The input data are: diameter, roughness coefficient, pressure variation, emitter operational pressure, relationship between emitter discharge and pressure. The output data are: line length, discharge and length of the each section with different spacing between drippers, total discharge in the lateral line, multiple outlet adjustment coefficient, head losses, localized head loss, pressure variation, number of emitters, spacing between emitters, discharge in each emitter, and discharge per linear meter. The mathematical model developed was compared with the lateral line length obtained with the algebraic solution generated by the Darcy-Weisbach equation. The NLP model showed the best results since it generated the greater gain in the lateral line length, maintaining the uniformity and the flow variation under acceptable standards. It had also the lower flow variation, so its adoption is feasible and recommended.
Resumo:
The use of non-pressure compensating drip hose in horticultural and annual cycle fruits is growing in Brazil. In this case, the challenge for designers is getting longer lateral lines with high values of uniformity. The objective of this study was to develop a model to design longer lateral lines using non-pressure compensating drip hose. Using the developed model, the hypotheses to be evaluated were: a) the use of two different spacing between emitters in the same lateral line allows longer length; b) it is possible to get longer lateral lines using high values of pressure variation in the lateral lines since the distribution uniformity stays below allowable limits. A computer program was developed in Delphi based on the model developed and it is able to design lateral lines in level using non-pressure compensating drip hose. The input data are: desired distribution uniformity (DU); initial and final pressure in the lateral line; coefficients of relationship between emitter discharge and pressure head; hose internal diameter; pipe cross-sectional area with the dripper; and roughness coefficient for the Hazen-Williams equation. The program allows calculate the lateral line length with three possibilities: selecting two spacing between emitters and defining the exchange point; using two pre-established spacing between emitters and calculating the length of each section with different spacing; using one emitter spacing. Results showed that the use of two sections with different spacing between drippers in the lateral line didn't allow longer length but got better uniformity when compared with lateral line with one spacing between emitters. The adoption of two spacing increased the flow rate per meter in the final section which represented approximately 80% of the lateral line total length and this justifies their use. The software allowed DU above 90% with pressure head variation of 40% and the use of two spacing between emitters. The developed model/software showed to be accurate, easy to handle and useful for lateral line design using non-pressure compensating drip hose.
Resumo:
The phases of a transmission line are tightly coupled due to mutual impedances and admittances of the line. One way to accomplish the calculations of currents and voltages in multi-phase lines consists in representing them in modal domain, where its n coupled phases are represented by their n propagation modes. The separation line in their modes of propagation is through the use of a modal transformation matrix whose columns are eigenvectors associated with the parameters of the line. Usually, this matrix is achieved through numerical methods which do not allow the achievement of an analytical model for line developed directly in the phases domain. This work will show an analytical model for phase currents and voltages of the line and results it will be applied to a hypothetical two-phase. It will be shown results obtained with that will be compared to results obtained using a classical model. © 2012 IEEE.
Resumo:
A transmission line digital model is developed direct in the phase and time domains. The successive modal transformations considered in the three-phase representation are simplified and then the proposed model can be easily applied to several operation condition based only on the previous knowing of the line parameters, without a thorough theoretical knowledge of modal analysis. The proposed model is also developed based on lumped elements, providing a complete current and voltage profile at any point of the transmission system. This model makes possible the modeling of non-linear power devices and electromagnetic phenomena along the transmission line using simple electric circuit components, representing a great advantage when compared to several models based on distributed parameters and inverse transforms. In addition, an efficient integration method is proposed to solve the system of differential equations resulted from the line modeling by lumped elements, thereby making possible simulations of transient and steady state using a wide and constant integration step. © 2012 IEEE.
Resumo:
This paper presents a method for analyzing electromagnetic transients using real transformation matrices in three-phase systems considering the presence of ground wires. So, for the Z and Y matrices that represent the transmission line, the characteristics of ground wires are not implied in the values related to the phases. A first approach uses a real transformation matrix for the entire frequency range considered in this case. This transformation matrix is an approximation to the exact transformation matrix. For those elements related to the phases of the considered system, the transformation matrix is composed of the elements of Clarke's matrix. In part related to the ground wires, the elements of the transformation matrix must establish a relationship with the elements of the phases considering the establishment of a single homopolar reference in the mode domain. In the case of three-phase lines with the presence of two ground wires, it is unable to get the full diagonalization of the matrices Z and Y in the mode domain. This leads to the second proposal for the composition of real transformation matrix: obtain such transformation matrix from the multiplication of two real and constant matrices. In this case, the inclusion of a second matrix had the objective to minimize errors from the first proposal for the composition of the transformation matrix mentioned. © 2012 IEEE.
Resumo:
The objective of this paper is to show a methodology to estimate transmission line parameters. The method is applied in a single-phase transmission line using the method of least squares. In this method the longitudinal and transversal parameters of the line are obtained as a function of a set of measurements of currents and voltages (as well as their derivatives with respect to time) at the terminals of the line during the occurrence of a short-circuit phase-ground near the load. The method is based on the assumption that a transmission line can be represented by a single circuit π. The results show that the precision of the method depends on the length of the line, where it has a better performance for short lines and medium length. © 2012 IEEE.
Resumo:
This paper proposes a set of performance factors for load characterization and revenue metering. They are based on the Conservative Power Theory, and each of them relates to a specific load non-ideality (unbalance, reactivity, distortion). The performance factors are capable to characterize the load under different operating conditions, considering also the effect of non-negligible line impedances and supply voltage deterioration. © 2012 IEEE.
Digital filtering of oscillations intrinsic to transmission line modeling based on lumped parameters
Resumo:
A correction procedure based on digital signal processing theory is proposed to smooth the numeric oscillations in electromagnetic transient simulation results from transmission line modeling based on an equivalent representation by lumped parameters. The proposed improvement to this well-known line representation is carried out with an Finite Impulse Response (FIR) digital filter used to exclude the high-frequency components associated with the spurious numeric oscillations. To prove the efficacy of this correction method, a well-established frequency-dependent line representation using state equations is modeled with an FIR filter included in the model. The results obtained from the state-space model with and without the FIR filtering are compared with the results simulated by a line model based on distributed parameters and inverse transforms. Finally, the line model integrated with the FIR filtering is also tested and validated based on simulations that include nonlinear and time-variable elements. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
(-)-Cubebin is a lignan extracted from the seeds of the pepper Piper cubeba, a commonly eaten spice with beneficial properties, including trypanocidal, anti-inflammatory, analgesic, anti-proliferative and leishmanicidal activities. Because of its therapeutic potential, we investigated the effects of (-)-cubebin on the cytotoxicity, cell proliferation kinetics, mutagenicity and expression of p38 MAP kinase and glutathione S-transferase a2 (GSTa2) using real-time RT-PCR in Rattus norvegicus hepatoma cells. We found that 280 μM (-)-cubebin was cytotoxic after 24, 48 and 72. h of exposure, but not mutagenic at 0.28 μM, 2.8 μM and 28 μM after 26. h. Similarly, exposure to 0.28 μM, 2.8 μM and 28 μM (-)-cubebin for 24, 48, 72 and 96. h did not alter the cell proliferation kinetics. Cells exposed to 28 μM (-)-cubebin for 24. h did not exhibit changes in p38 MAP kinase and GSTa2 expression, indicating that cellular changes were not induced by extracellular stimuli and that (-)-cubebin is likely not metabolized via this pathway. Our results suggest that high levels of (-)-cubebin should be consumed with caution due to the cytotoxic effect observed at the highest concentration. However, at lower concentrations, no cytotoxic, mutagenic or proliferative effects were observed, providing further evidence of the safety of consuming (-)-cubebin. © 2013 Elsevier Inc.
Resumo:
The phases of a transmission line are tightly coupled due to mutual impedances and admittances of the line. One way to accomplish the calculations of currents and voltages in multi phase lines consists in representing them in modal domain, where its n coupled phases are represented by their n propagation modes. The separation line in their modes of propagation is through the use of a modal transformation matrix whose columns are eigenvectors associated with the parameters of the line. Usually, this matrix is achieved through numerical methods which do not allow the achievement of an analytical model for line developed directly in the phases domain. This work will show an analytical model for phase currents and voltages of the line and results it will be applied to a hypothetical two-phase. It will be shown results obtained with that will be compared to results obtained using a classical model © 2003-2012 IEEE.