102 resultados para Frictional Contact Between Deformable Bodies


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the control, epidemiological, pathological, and molecular aspects of an outbreak of meningoencephalitis in calves due to bovine herpesvirus 5 at a feedlot with 540 animals in Sa (a) over tildeo Paulo State, Brazil. The introduction of new animals and contact between the resident animals and the introduced ones were most likely responsible for virus transmission. Bovine herpesvirus 1 vaccine was used, resulting in the efficacy of the outbreak control, although two bovine herpesvirus 1 positive animals, vaccinated and revaccinated, presented meningoencephalitis, thereby characterizing vaccinal failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to assess the bone repair process of crystallized Biosilicate in surgically created defects on rats' calvaria. This biomaterial was recently developed for odontological use. We used fifteen rats (rattus norvegicus albinus, Wistar), and two 5 mm surgical defects were performed on each of them; the defects were made with trephine drill on the calvarium region prior to the biomaterial placement. Groups were divided as follows: Group 1-defect filled with clot; Group 2-defect filled with crystallized Biosilicate. After 7, 14 and 28 days the animals were killed, the parts were retrieved and slides were prepared for histological studies. Bone formation was satisfactory in all groups, with direct contact between biomaterial surface and bone and absence of infection signs. The 28 days periods showed better results, and statistically significant difference between Clot Group (90.2 %) and Biosilicate (58 %; p = 0.002) was seen, regarding presence of bone tissue on the surgical defects. Our study revealed that defects filled with clot present better results on bone formation compared to crystallized Biosilicate, which is considered a biocompatible material with favorable osteoconductive properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências Sociais - FCLAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need for a closer contact between students and the community reality, as well as, the necessity of providing an education that can result in social changes early in life were crucial for the development of the Extension Project : Oral Health Education, which was developed in Public Child Care Schools in Araçatuba. The aim of this article is to describe the project, emphasizing its educational aspects and to share this experience in order to allow for reflection about this practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article makes a connection between Benjamin and Carpeaux in order to identify points of contact between the two authors. In this methodological operation assumes the crucial role collating Wege nach Rom with Benjamin's, Passages, which leads us to speak of a Carpeaux reader of Benjamin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Psicologia do Desenvolvimento e Aprendizagem - FC

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of the study was to use scanning electron microscopy and energy dispersive x-ray spectrometry to assess possible morphologic and chemical changes after performing double-insertion and pullout tests of implants of different shapes and surface treatments. Four different types of implants were used—cylindrical machined-surface implants, cylindrical double-surface–treated porous implants, cylindrical surface-treated porous implants, and tapered surface-treated porous implants—representing a total of 32 screws. The implants were inserted into synthetic bone femurs, totaling 8 samples, before performing each insertion with standardized torque. After each pullout the implants were analyzed by scanning electron microscopy and energy dispersive x-ray spectrometry using a universal testing machine and magnified 35 times. No structural changes were detected on morphological surface characterization, only substrate accumulation. As for composition, there were concentration differences in the titanium, oxygen, and carbon elements. Implants with surface acid treatment undergo greater superficial changes in chemical composition than machined implants, that is, the greater the contact area of the implant with the substrate, the greater the oxide layer change. In addition, prior manipulation can alter the chemical composition of implants, typically to a greater degree in surface-treated implants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core - MAu; zirconia core - MZi) and the quality of the veneer/core interface (complete bonded - MZi; incomplete bonded - MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.