104 resultados para Frequency dependence parameters
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Low crystalline PZT powder samples were successfully synthesized using polymeric precursor method and slow decomposition steps. The polymeric resin precursor was thermal treated in a muffle type oven varying the temperature from 250 °C to 700 °C and the time from 3 to 24 hours in order to investigate the order/disorder mechanism toward the amorphous powders. Powder samples with low crystalline phases were obtained at lower temperatures and long time of thermal treatment, demonstrating a kinetic dependence for organic removal and a thermodynamic barrier for crystallization processes. Through XRD and FTIR spectroscopy characterizations the long time thermal treated samples showed to be composed of the solid solution of metal oxides in absent of organic matter, originating broad XRD peaks profiles and no carbonaceous bands in FTIR spectra. A Photoluminescence characterization showed that the peak emission is higher for disordered and homogeneous phases, which only can be reached through the long time of thermal treatment.
Resumo:
Background/aims: Cardiovascular diseases are major causes of mortality in chronic renal failure patients before and after renal transplantation. Among them, coronary disease presents a particular risk; however, risk predictors have been used to diagnose coronary heart disease. This study evaluated the frequency and importance of clinical predictors of coronary artery disease in chronic renal failure patients undergoing dialysis who were renal transplant candidates, and assessed a previously developed scoring system. Methods: Coronary angiographies conducted between March 2008 and April 2013 from 99 candidates for renal transplantation from two transplant centers in Sao Paulo state were analyzed for associations between significant coronary artery diseases (>= 70% stenosis in one or more epicardial coronary arteries or >= 50% in the left main coronary artery) and clinical parameters. Results: Univariate logistic regression analysis identified diabetes, angina, and/or previous infarction, clinical peripheral arterial disease and dyslipidemia as predictors of coronary artery disease. Multiple logistic regression analysis identified only diabetes and angina and/or previous infarction as independent predictors. Conclusion: The results corroborate previous studies demonstrating the importance of these factors when selecting patients for coronary angiography in clinical pretransplant evaluation.
Effects of maternal exposure to the galactagogue Sulpiride on reproductive parameters in female rats
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Voltages and currents in the transmission line are described by differential equations that are difficult to solve due soil and skin effect that has to be considered for accurate results, but it increases their complexity. Therefore there are some models to study the voltages and currents along in transmission line. The distributed parameters model that transforms the equations in time domain to the frequency domain and once the solutions are obtained, they are converted to time domain using the Inverse Laplace Transform using numerical methods. Another model is named lumped parameters model and it considers the transmission line represented by a pi-circuit cascade and the currents and voltages are described by state equations. In the simulations using the lumped parameters model, it can be observed the presence of spurious oscillations that are independent of the quantity of pi-circuits used and do not represent the real value of the transient. In this work will be projected a passive low-pass filter directly inserted in the lumped parameters model to reduce the spurious oscillations in the simulations, making this model more accurate and reliable for studying the electromagnetic transients in power systems.
Resumo:
Introduction: The frequency of surgical procedures has increased steadily in recent decades, including the myocardial revascularization.Objectives: To demonstrate the importance of physiotherapy in the preoperative period of cardiac surgery in relation to the reduction of hospital stay, changes in lung volumes and respiratory muscle strength.Methods: We conducted a prospective study with patients undergoing myocardial revascularization, the Hospital das Clinicas da Universidade Estadual Paulista (UNESP)/Botucatu - SP. We evaluated 70 patients of both genders, aged between 40 and 75 years, subdivided into two groups: group I - 35 patients of both genders, who received a written protocol guidance, breathing exercises and respiratory muscle training in the preoperative period and group II - 35 patients of both genders, who received only orientation of the ward on the day of surgery. This study was approved by the Ethics Committee of UNESP /Botucatu - SP.Results: Maximal inspiratory pressure in third postoperative day and fifth postoperative day and significant difference between groups, being better for the intervention group. Expiratory pressure was significant in fifth postoperative day in the intervention group compared to controls. The difference of length of hospital stay in the postoperative was found between the groups with shorter hospital stay in the group receiving preoperative therapy.Conclusion: Physical therapy plays an important role in the preoperative period, so that individuals in the intervention group more readily restored the parameters evaluated before surgery, in addition, there was a decrease in the time of the postoperative hospital stay. Thus, it is thought the cost-effectiveness of a program of preoperative physiotherapy.
Resumo:
This paper presents an investigation into some practical issues that may be present in a real experiment, when trying to validate the theoretical frequency response curve of a two degree-of-freedom nonlinear system consisting of coupled linear and nonlinear oscillators. Some specific features, such as detached resonance curves, have been theoretically predicted in multi degree-of-freedom nonlinear oscillators, when subject to harmonic excitation, and the system parameters have been shown to be fundamental in achieving such features. When based on a simplified model, approximate analytical expression for the frequency response curves may be derived, which may be validated by the numerical solutions. In a real experiment, however, the practical achievability of such features was previously shown to be greatly affected by small disturbances induced by gravity and inertia, which led to some solutions becoming unstable which had been predicted to be stable. In this work a practical system configuration is proposed where such effects are reduced so that the previous limitations are overcome. A virtual experiment is carried out where a detailed multi-body model of the oscillator is assembled and the effects on the system response are investigated.
Resumo:
Frequency upconversion (UC) processes involving energy transfer (ET) among Nd 3+ and Pr 3+ ions in a fluoroindate glass are reported. In a first experiment, the excitation of Pr 3+ [transition 3H 4→ 1D 2] and of Nd 3+ [transition 4I 9/2→( 2G 7/2+ 4G 5/2)] was achieved with a dye laser operating in the 575-590 nm range. In a second experiment, the Nd 3+ ions were excited with the second harmonic of a Nd: YAG laser at 532 nm. The ET processes leading to UC in both experiments were studied by monitoring the blue fluorescence decay at 480 nm due to the transition 3P 0→ 3H 4 in Pr 3+. In the more relevant UC process, quartets of ions (Nd-Nd-Pr-Pr) are excited due to absorption of three laser photons by two Nd 3+ ions which transfer their energy to two Pr 3+ ions. Each Pr 3+ ion promoted to the 3P 0 level decays to the ground state emitting one photon in the blue region. This conclusion was achieved investigating the dependence of the UC fluorescence intensity as a function of laser intensity, samples concentrations, and temporal behavior of the UC signal. Other UC processes involving nonisoionic groups of three ions are also reported. © 2002 American Institute of Physics.
Resumo:
Most work on supersingular potentials has focused on the study of the ground state. In this paper, a global analysis of the ground and excited states for the successive values of the orbital angular momentum of the supersingular plus quadratic potential is carried out, making use of centrifugal plus quadratic potential eigenfunction bases. First, the radially nodeless states are variationally analyzed for each value of the orbital angular momentum using the corresponding functions of the bases; the output includes the centrifugal and frequency parameters of the auxiliary potentials and their eigenfunction bases. In the second stage, these bases are used to construct the matrix representation of the Hamiltonian of the system, and from its diagonalization the energy eigenvalues and eigenvectors of the successive states are obtained. The systematics of the accuracy and convergence of the overall results are discussed with emphasis on the dependence on the intensity of the supersingular part of the potential and on the orbital angular momentum.
Resumo:
Objectives. To compare the frequency of another primary malignancy in patients with differentiated thyroid carcinoma (DTC) who received radioiodine therapy or not ((131)I). Material and Methods. 168 cases of DTC patients were retrospectively evaluated as to the frequency of another neoplasia by comparing patients with and without it, taking into account clinical, laboratory, and therapeutic parameters. Results. Another primary malignancy occurred in 8.9% of patients. Of these, 53.3% showed the malignancy before (131)I and 46.7% after it. By comparing both groups, the age at the moment of diagnosis of another neoplasia was 46.1 ± 20.2 years for the group before (131)I therapy and of 69.4 ± 11.4 years for the group after it (P = 0.02). Of the 148 patients treated with (131)I, 4.7% developed another malignancy. The latter were older (61 ± 17 years) than those who did not show another cancer type (44.1 ± 14.2 years) (P < 0.05). Conclusion. The frequency of another neoplasia found after (131)I was similar to that found before (131)I.
Resumo:
The present study aimed to compare elderly and young female voices in habitual and high intensity. The effect of increased intensity on the acoustic and perceptual parameters was assessed. Sound pressure level, fundamental frequency, jitter, shimmer, and harmonic to noise ratio were obtained at habitual and high intensity voice in a group of 30 elderly women and 30 young women. Perceptual assessment was also performed. Both groups demonstrated an increase in sound pressure level and fundamental frequency from habitual voice to high intensity voice. No differences were found between groups in any acoustic variables on samples recorded with habitual intensity level. No significant differences between groups were found in habitual intensity level for pitch, hoarseness, roughness, and breathiness. Asthenia and instability obtained significant higher values in elderly than young participants, whereas, the elderly demonstrated lower values for perceived tension and loudness than young subjects. Acoustic and perceptual measures do not demonstrate evident differences between elderly and young speakers in habitual intensity level. The parameters analyzed may lack the sensitivity necessary to detect differences in subjects with normal voices. Phonation with high intensity highlights differences between groups, especially in perceptual parameters. Therefore, high intensity should be included to compare elderly and young voice.
Resumo:
A transmission line is characterized by the fact that its parameters are distributed along its length. This fact makes the voltages and currents along the line to behave like waves and these are described by differential equations. In general, the differential equations mentioned are difficult to solve in the time domain, due to the convolution integral, but in the frequency domain these equations become simpler and their solutions are known. The transmission line can be represented by a cascade of π circuits. This model has the advantage of being developed directly in the time domain, but there is a need to apply numerical integration methods. In this work a comparison of the model that considers the fact that the parameters are distributed (Universal Line Model) and the fact that the parameters considered concentrated along the line (π circuit model) using the trapezoidal integration method, and Simpson's rule Runge-Kutta in a single-phase transmission line length of 100 km subjected to an operation power. © 2003-2012 IEEE.
Resumo:
Objective To assess the diagnostic accuracy of the surface electromyography (sEMG) parameters associated with referred anterior knee pain in diagnosing patellofemoral pain syndrome (PFPS). Design Sensitivity and specificity analysis. Setting Physical rehabilitation center and laboratory of biomechanics and motor control. Participants Pain-free subjects (n=29) and participants with PFPS (n=22) selected by convenience. Interventions Not applicable. Main Outcome Measure The diagnostic accuracy was calculated for sEMG parameters’ reliability, precision, and ability to differentiate participants with and without PFPS. The selected sEMG parameter associated with anterior knee pain was considered as an index test and was compared with the reference standard for the diagnosis of PFPS. Intraclass correlation coefficient, SEM, independent t tests, sensitivity, specificity, negative and positive likelihood ratios, and negative and positive predictive values were used for the statistical analysis. Results The medium-frequency band (B2) parameter was reliable (intraclass correlation coefficient=.80–.90), precise (SEM=2.71–3.87 normalized unit), and able to differentiate participants with and without PFPS (P<.05). The association of B2 with anterior knee pain showed positive diagnostic accuracy values (specificity, .87; sensitivity, .70; negative likelihood ratio, .33; positive likelihood ratio, 5.63; negative predictive value, .72; and positive predictive value, .86). Conclusions The results provide evidence to support the use of EMG signals (B2 – frequency band of 45–96Hz) of the vastus lateralis and vastus medialis muscles with referred anterior knee pain in the diagnosis of PFPS.