134 resultados para Feixe de protóns
Resumo:
Radiotherapy is a field of medical physics, which has been going through a scientific and technological advancement, it is extreme important the professionals that work in this area continuous their study to improve the quality of service provided. For it, they should know the physical principles related as well their employment in radiotherapy. The electrons have been using in therapy of superficial tumors, because they show rapid decrease of dose in depth, they don’t expose the deeper tissues to radiation. The electron therapy has replaced the surface therapy with x-ray and mold brachytherapy, and nowadays, it represents 10 to 15% of radiotherapy treatments. This study brings the definition of physical parameters used in the dosimetry of electron beam, describes the tests for quality control of linear accelerator with a electrons beam, as well the activities realized in the Radiotherapy Division, of Hospital de Clinicas, in the Universidade Estadual of Campinas, in the Clinac 2100C machine
Resumo:
A protonterapia é um tipo de tratamento promissor quanto a diminuição de dose nos tecidos adjacentes ao tumor, devido às suas característica de deposição de energia ao interagir com a matéria. Para aumentar a acurácia do tratamento é necessário que as simulações sejam feitas a partir de um sistema de formação de imagem que utilize também um feixe de prótons, como a tomografia por feixe de prótons (pCT). Essa área atualmente está em desenvolvimento e se defronta com inúmeros problemas na formação de uma imagem precisa. Este trabalho tem o intuito de analisar a viabilidade de simulações computacionais para este tipo de feixe. O código computacional SRIM é um conjunto de programas que calcula o freamento e o alcance de íons ao interagir com a matéria. Esse cálculo baseia-se em ferramentas oriundas da mecânica quântica e também no método de Monte Carlo, para determinar, de modo probabilístico, trajetórias, colisões e ângulos. Foram realizadas simulações no programa SRIM para um alvo heterogêneo envolvendo água e osso cortical. Para analisar o comportamento do feixe transmitido, foram feitas alterações na posição e no tamanho da heterogeneidade. A partir dos dados obtidos pode-se obter valores médios, histogramas e gaussianas dos mesmos para cada simulação e tirar conclusões sobre a viabilidade e as dependências desse tipo de simulação
Resumo:
The treatment of a tumor with ionizing radiation is an ongoing process with well differentiated stages. These ones include the tumor diagnosis and location, the decision on the treatment strategy, the absorbed dose planning and calculation, the treatment administration, the absorbed dose verification and the evaluation of results in short and long terms. The quality of a radiotherapy procedure is closely linked to factors that may be classified as clinical, such as the diagnosis, the tumor location, the treatment strategy chosen and the continuous treatment reassessment; dosimetric or physical, such as the uncertainty in the dose calculation, its optimization and verification, the suitability of the equipment to provide a radiation beam consistent with the treatment planning; finally, others which are related to the practical application of radiotherapy treatment and the handling of the patient. In order to analyze the radiotherapy quality, one should realize that the three aspects (medical, physical or dosimetric and practical application) should be considered in a combined way. This means that numerous actions of the radiotherapists, medical physicists and technicians in radiotherapy should be held jointly and their knowledge level will significantly affect the treatment quality. In this study, the main physical parameters used in dosimetry are defined as well as determined experimentally for a linear accelerator Mevatron - MXT. With this, it is intended to provide recommendations for the physical aspects of Quality Assurance (QA) in the radiotherapy treatments, and these will usually be applied by professionals in Medical Physics. In addition to these instructions, it is recommended that additional texts are prepared to address in detail the clinical aspects of the treatments QA
Resumo:
The Medical Physics has been developing very fast due to the progress of the technologies and to the increase of the concerns with cure of diseases. One of the Medical Physics main performances at the present time is the use of ionizing radiations for cancer treatment, especially, services as Radiotherapy. The radiotherapy technique uses ionizing radiation with therapeutic end of cancer controls, avoiding your proliferation and it worsens of the patient. For the treatment a radiation bunch is used, with rectangular form, that it passes through the different types of tissues of the patient's body, and depending on the attenuation and of the depth of the fabrics, a great amount of energy is deposited inside in different points of the body. Like this, to plan this treatment type it should be obtained the dimension of the distribution and dose absorption along the volume. For this, it is necessary in the planning of the treatment of the cancer for radiotherapy to build isodose curves, which are lines that represent points of same amount of dose to be deposited in the area to be treated. To aid the construction of the curves of form isodose to reach the best result in the planning of the treatment, in other words, a great planning, providing the maximum of dose in the tumor and saving the healthy and critical organs, it has been using mathematical tools and computational. A plan of cancer treatment for radiotherapy is considered great when all the parameters that involve the treatment, be them physical or biological, they were investigated and adapted individually for the patient. For that, is considered the type and the location of the tumor, worrying about the elimination of the cancer without damaging the healthy tissue of the treated area, mainly the risk organs, which are in general very sensitive to the radiations. This way, the optimization techniques... (Complete abstract click electronic access below)
Resumo:
Qualidade na coleta de dados do feixe de radiação, modelagem por meio do sistema de planejamento de tratamento (SPT) e controle da qualidade do processo envolvido são cruciais à fidedignidade do serviço de radioterapia de forma a contribuir à eficácia do tratamento e segurança do principal ente envolvido no final de toda essa sistemática, o paciente. Para isso foi proposto nesse presente trabalho a coleta de dados do feixe de raios-x de 6MV seguido da introdução desses dados ao SPT para processo de modelagem computacional que teve agregado, a todo esses processos, o controle da qualidade segundo critérios de aceitação
Resumo:
Due the differences between interaction physics process with matter for protons and photons, the proton beam tomography (pCT) has some vantages to comparison with conventional tomography. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. The pCT allow not only view the internal structure of an object without destroying it, but also directly measure of volume density of electrons. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. At the same time, there are many scientific and technical aspects to a detailed study: the capacity and limitations of the pCT methods are not well clarified. Through computations, based on Monte Carlo Method was carried out a detailed study of the contribution of non-elastic nuclear spreading, and together was compared with an analytical model for the deflection angle and the lateral deflection of protons in the target volume. The programs used were SRIM 2006 code and MCNPX v.2.50 code
Resumo:
Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service
Resumo:
Thin films of Ga1-xMnxN have great interest in its potential for control of electron spin (spintronics), in most cases this material is synthesized by techniques that have a high degree of control the deposition parameters, such as molecular beam epitaxy (MBE) and deposition of metalorganic chemical vapor deposition (MOCVD). The sputtering technique is an alternative route to produce such materials. Here we study the film deposition Ga1-xMnxN by reactive sputtering technique and apply enhancements such as a glove box, a residual gas analyzer and temperature control system, in order to growth films epitaxially using an analysis of the preconditions of films analyzed by spectroscopic techniques and microscopic. These procedures helped to improve the technique of deposition by cleaning substrates in an inert environment, and by the analysis of trace gases and heating the substrate holder as explained in the literature. Through the applications and comparisons it can be pointed out that the technique has the advantage of its simplicity and relatively low cost compared to MBE and MOCVD, but produces polycrystalline material
Resumo:
This paper presents a study about the operation of the major system’s components of a linear particle acclerator (Linac). It addresses the components mainly responsible for the formation of the beam, through the inclusion of several block diagrams showing the details of the structure. Among the systems discussed may be mentioned the system modulator, automatic frequency control, dosimetry and auxiliary systems. The main objective is the dissemination of basic technology applied in linear accelerators and create literature about this subject in national language. Despite the high complexity and large number of devices that comprise a linear accelerator, it has been developed an easy to understand text that adresses the most relevant issues to the operation of the linear accelerator from the point of view of electrical engineering
Resumo:
The Therapy with proton beam has shown more e ective than Radiotherapy for oncology treatment. However, to its planning use photon beam Computing Tomography that not considers the fundamentals di erences the interaction with the matter between X-rays and Protons. Nowadays, there is a great e ort to develop Tomography with proton beam. In this way it is necessary to know the most likely trajectory of proton beam to image reconstruction. In this work was realized calculus of the most likely trajectory of proton beam in homogeneous target compound with water that was considered the inelastic nuclear interaction. Other calculus was the analytical calculation of lateral de ection of proton beam. In the calculation were utilized programs that use Monte Carlo Method: SRIM 2006 (Stopping and Range of Ions in Matter ), MCNPX (Monte Carlo N-Particle eXtended) v2.50. And to analytical calculation was employed the software Wolfram Mathematica v7.0. We obtained how di erent nuclear reaction models modify the trajectory of proton beam and the comparative between analytical and Monte Carlo method
Resumo:
Radiotherapy is a branch of medical physics related to the treatment of malignant neoplasm, being an important instrument in the fight against cancer, when combined with the effort of a multidisciplinary team, composed of, physicians, physicists, nurses and technicians. Every year more than 3.5 million new cases of cancer are recorded in the world, being the prostate cancer responsible for approximately 25% of this amount (INCA and IARC, 2008). In this type of cancer, radiotherapy is a method indicated for treatement. The technological advance in this area over years has allowed a greater accuracy in the tumor location, more conformation of the radiation beam around the tumor, reducing the dose in healthy tissues and a consequent dose increase on treatment (Bedford et al., 1999). A radiotherapy planning, in which the physicist develops an important role, is composed of several steps, including choosing the best configuration of treatment beams. This choice has a close relationship with success of therapy and is critical to achieve the best distribution of dose inside the tumor and expose the least as possible the healthy tissue to radiation. In this work, two options for setting up camps in the first phase in a treatment of prostate cancer were simulated in computer planning: 4 fields orthogonal or “Box” with gantry angles in 00, 1800, 2700 e 90° and 4 fields angled or “X” (1350, 450, 3150 e 2250). The percentage of the rectal volume exposed to 40, 50, 60, 72 and 76 Gy should be limited to 60, 50, 25, 15 and 5% respectively (Greco et al., 2003). The femoral toxicity have limited dose by 70% of the total dose prescribed in a prostate treatment (Bedford et al., 1999). The planning of 27 patients with prostate adenocarcinoma submitted to 3D conformal radiotherapy were accompanied. As a result, it was assessed that the best TCP (tumor control probability)... (Complete abstract click electronic access below)
Resumo:
O trabalho propõe rotinas computacionais usando o Método de Monte Carlo com o Código MCNP-5, para analisar os perfis de dose de radiação liberada nos tratamentos de tumores de pele e otimizar os cálculos radiométricos dos feixes de radiação estudados. Foram realizadas medidas dosimétricas do feixe de radiação, comparando os resultados obtidos com os respectivos valores fornecidos pelo serviço de física médica das instituições, com resultados informados pelo fabricante do equipamento e com as simulações computacionais efetuadas com o Código MCNP-5. A quantificação dos erros relativos percentual entre os resultados simulados e os fornecidos pelo Serviço de Radioterapia (E1), os informados pelo fabricante (E2) e os medidos experimentalmente (E3) são inferiores a 4,0% e validam a metodologia computacional proposta para avaliação do comportamento do feixe de raios-X superficial e do feixe de raios γ da unidade de Cobaltoterapia. A metodologia de análise do espectro energético e da curva de porcentagem de dose profunda (PDP) desenvolvida neste trabalho pode ser estendida para estudos de outros feixes clínicos e subsidiar os dados radiométricos utilizados nos planejamentos e cálculos de dose realizados pelo profissional da física médica na sua rotina nos Serviços de Radioterapia
Resumo:
The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose
Resumo:
In radiation theraphy with electron beam, the electrons are produced in linear accelerators, and energy the most used have between 4MeV and 20MeV. Generally, the treatments are done for superficial injuries, because the low penetration of these particles. In this work a system for calculation of monitor units (U.M.) for cases of treatments with electron beam was developed. The Excel program of Microsoft was used and is easily found in the operational system of the personal microcomputers. In the Excel has been inserted the pertinent data of the linear accelerator of Varian, model 2100C, used in the Service of radiation theraphy of the Hospital of the Clinics of the College of Medicine of the UNESP of Botucatu. For some values of the physical parameters, such as: factors field and factors calibration, not supplied in the tests of acceptance of the machine, still proceeded calculations from interpolation and extrapolation. The mathematical formulas for automatic search of these and others factors used in the calculations of the determination of the U.M had been developed in agreement available routines in Excel. For this the functions had been used the function IF (that it imposes search condition) and the PROCH (that looks a value in a column from determined line), beyond the basic functions of addition, multiplication and division. It is intended to optimize the routine of the Services of radiation theraphy that perform through eletrontheraphy procedures, speeding the calculations and minimizing the occurrence of errors and uncertainties deriving of the maken a mistake manipulation of the parameters gotten in tables of data of electron beams
Resumo:
A Zona de Falha de Cássia constitui um feixe de falhas de direção preferencial NW-SE e aproximadamente 2 km de largura. Dados de campo, petrográficos e microestruturais evidenciam uma longa história deformacional da zona de falha. Assim, foram caracterizadas três fases de atividade/movimentação da Zona de Falha de Cássia. A primeira fase (précambriana) é caracterizada por deformação em regime dúctil, acarretando na geração de milonitos formados em condições metamórficas de fácies xisto verde. Este é o estágio de formação da falha, apresentando caráter transcorrente oblíqua, com movimentação sinistral inversa. A segunda fase corresponde a uma reativação da zona de falha como uma falha normal, com bloco alto a NE e bloco baixo a SW da referida estrutura. Seu registro é dado pela ocorrência localizada de brechas e cataclasitos. Este episódio de deformação eminentemente rúptil é correlacionado com o Soerguimento do Alto Paranaíba, o que indica movimentação da falha no Neocretáceo. A terceira e última fase é marcada pela formação de depósitos sedimentares plio-pleistocênicos compostos por brecha sedimentar de leques aluviais e sedimentos argilosos lacustres. Tais depósitos são interpretados como originados pelo represamento da drenagem subatual e conseqüente mudança do nível de base local, em decorrência de uma reativação da Zona de Falha de Cássia. O referido pacote sedimentar apresenta-se localmente cortado por fraturas, zonas brechadas e falhas, caracterizando atividade neotectônica na região. Além disso, foi mostrada a forte influência da zona de falha no desenvolvimento da paisagem da região, sendo constatada a inversão do relevo e da drenagem na área estudada.